Performance of surge arrester to multiple lightning strokes on nearby distribution transformer

被引:0
|
作者
Omidiora, M. A. [1 ]
Lehtonen, M. [1 ]
机构
[1] Aalto Univ, Power Syst & High Voltage Lab, FIN-02150 Espoo, Finland
关键词
lightning strokes; surge arrester; ATPDraw; transient overvoltages;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Overhead distribution lines are prone to lightning overvoltages due to their configurations and characteristics. Metal Oxide Varistor (MOVs) arresters for many years have proven to be more advantageous than others arresters in lightning surge protection; therefore it is worthwhile to continually assess the behavior and performance of these arresters to different kind of overvoltages caused by lightning strokes for power system applications. This paper presents the performance of MOV arresters to multiple lightning strokes nearby a substation transformer. All simulations were performed with Alternative Transients Program/Electromagnetic Transients Program (ATP/EMTP Program).
引用
收藏
页码:59 / +
页数:3
相关论文
共 50 条
  • [21] Performance evaluation of distribution and low-voltage networks under direct lightning flashes with paralleled triac-surge arrester
    Sabiha, Nehmdoh A.
    Alkhammash, Hend I.
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 225
  • [22] Estimation of the surge arrester outage rate caused by lightning overvoltages
    Savic, MS
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (01) : 116 - 122
  • [23] A study on observation results of lightning phenomena on distribution lines based on a lightning-surge analysis model for direct lightning strokes
    High Voltage and Insulation Group, R and D Center, TEPCO, 4-1, Egasaki-cho, Tsurumi-ku, Yokohama 230-8510, Japan
    不详
    IEEJ Trans. Power Energy, 2006, 12 (1295-1303+15):
  • [24] INSULATION COORDINATION BETWEEN DISTRIBUTION TRANSFORMER AND DISTRIBUTION TRANSFORMER AND DISTRIBUTION ARRESTER
    GOODMAN, EA
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1973, PA92 (06): : 1804 - 1804
  • [25] Appropriate Surge Arrester Lead Lengths for Improved Distribution Transformer Protection - Kenyan Case Study
    Ndirangu, Julius
    Kimemia, Peter
    Ndolo, Raphael
    Nderu, John
    Irungu, George
    2020 IEEE PES & IAS POWERAFRICA CONFERENCE, 2020,
  • [26] A simulation study of induced surge on low voltage distribution system nearby the lightning point
    Oshiro R.
    Isa S.
    Kaneko E.
    IEEJ Transactions on Power and Energy, 2010, 130 (07) : 687 - 693+8
  • [27] A study of Degradation Characteristics and Diagnostic Method of Lightning Surge Arrester for 6.6 kV Power Distribution Lines
    Yoneda, Yasuaki
    Koga, Yoshiyasu
    Sato, Tomoyuki
    Yokoyama, Shigeru
    2018 34TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2018), 2018,
  • [28] Protection of the distribution lines against lightning overvoltages by surge arrester in the context of distributed generation and smart grids
    Araujo, M. A.
    Flauzino, R. A.
    Batista, O. E.
    Moraes, L. A.
    2013 IEEE PES CONFERENCE ON INNOVATIVE SMART GRID TECHNOLOGIES (ISGT LATIN AMERICA), 2013,
  • [29] Analysis of Thermal Effects for Polymer-Housed Metal-Oxide Surge Arrester Under Multiple Strokes
    Huang, Lin
    Zhou, Lijun
    Chen, Wei
    Wei, Renwei
    Zhang, Dong
    Wang, Dongyang
    Zhao, Haiquan
    Ma, Yutang
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (05) : 3917 - 3927
  • [30] Surge voltages and currents into a customer due to nearby lightning
    Ametani, Akihiro
    Matsuoka, Kae
    Omura, Hiroshi
    Nagai, Yoshiyuki
    ELECTRIC POWER SYSTEMS RESEARCH, 2009, 79 (03) : 428 - 435