Study on the graphite and carbon fiber modified asphalt concrete

被引:138
作者
Liu Xiaoming [1 ]
Wu Shaopeng [2 ]
机构
[1] Cent S Univ, Sch Civil Engn & Architecture, Changsha 410075, Hunan, Peoples R China
[2] Wuhan Univ Technol, Key Lab Silicate Mat Sci & Engn, Minist Educ, Wuhan 430070, Peoples R China
关键词
Asphalt concrete; Indirect tensile test; Mechanical property; Electrical property; Self-monitoring; ELECTRICAL-PROPERTIES; COMPOSITES; PIEZORESISTIVITY;
D O I
10.1016/j.conbuildmat.2010.11.082
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The mechanical and electrical properties of graphite and carbon fiber modified asphalt concrete were measured in this paper through the indirect tensile test. The experimental results indicate that the mechanical properties of asphalt mixture are influenced by the addition of conductive component like graphite and carbon fiber, When the graphite content increased from 0 to 22 vol.%, Marshall stability decreased from 12.8 kN to 9.43 kN and residual stability from 91.1% to 87.2%. Rutting dynamic stability decreased from 3318 times/mm to 2619 times/mm. After adding the carbon fiber, when the carbon fiber content increased from 0 to 2 vol.%, their Marshall stability and residual stability increased from 12.8 kN to 13.5 kN and residual stability from 91.1% to 92.7%. Rutting dynamic stability increased from 3318 times/mm to 3403 times/mm. When modified through combination effect of graphite and carbon fiber mixed fillers, the mechanical performance and electrical property were improved greatly, their Marshall stability and residual stability has increased from 9.43 kN to 12.1 kN and residual stability from 87.2% to 89.2%. Rutting dynamic stability increased from 2619 times/mm to 3292 times/mm. Furthermore, the resilient modulus is influenced by the addition of graphite, the value of resilient modulus is as much as that of the original, it is 90% when graphite is 30 vol.% and is 70% when graphite is 45 vol.%. The electrical resistance increases reversibly with increasing tensile strain either under dynamic indirect tensile testing or static indirect tensile testing, graphite and carbon fiber modified asphalt concretes are effective for the self-monitoring of strain. It is foreseen that the strain-stress self monitoring is valuable for weighing, traffic monitoring, border monitoring and structural vibration control. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1807 / 1811
页数:5
相关论文
共 12 条
[1]  
[Anonymous], AASHTO Designation: T 272-18, One-Point Method for Determining Maximum Dry Density and Optimum Moisture
[2]  
[Anonymous], 1996, Superpave Mix Design
[3]  
Liu Xiao-Ming, 2009, Journal of Central South University (Science and Technology), V40, P1465
[4]   Self-monitoring application of asphalt concrete containing graphite and carbon fibers [J].
Liu Xiaoming ;
Wu Shaopeng ;
Ning, Li ;
Bo, Gao .
JOURNAL OF WUHAN UNIVERSITY OF TECHNOLOGY-MATERIALS SCIENCE EDITION, 2008, 23 (02) :268-271
[5]   Properties evaluation of asphalt-based composites with graphite and mine powders [J].
Liu, Xiaoming ;
Wu, Shaopeng ;
Ye, Qunshan ;
Qiu, Han ;
Li, Bo .
CONSTRUCTION AND BUILDING MATERIALS, 2008, 22 (03) :121-126
[6]  
Liu Xiaoming, 2010, Journal of Wuhan University of Technology (Transportation Science & Engineering), V34, P545, DOI 10.3963/j.issn.1006-2823.2010.03.029
[7]   Research on the conductive asphalt concrete's piezoresistivity effect and its mechanism [J].
Liu, Xiaoming ;
Wu, Shaopeng .
CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (08) :2752-2756
[8]   Effects of carbon black on the thermal, mechanical and electrical properties of pitch-matrix composites [J].
Wen, SH ;
Chung, DDL .
CARBON, 2004, 42 (12-13) :2393-2397
[9]  
WEN SH, 2005, J MATER SCI, P3897
[10]   Investigation of the conductivity of asphalt concrete containing conductive fillers [J].
Wu, SP ;
Mo, LT ;
Shui, ZH ;
Chen, Z .
CARBON, 2005, 43 (07) :1358-1363