Simulation of blood flow in human aorta with emphasis on outlet boundary conditions

被引:87
作者
Benim, A. C. [1 ]
Nahavandi, A. [1 ]
Assmann, A. [2 ]
Schubert, D. [3 ]
Feindt, P. [2 ]
Suh, S. H. [4 ]
机构
[1] Duesseldorf Univ Appl Sci, Dept Mech & Proc Engn, CFD Lab, D-40474 Dusseldorf, Germany
[2] Univ Hosp, Dept Thorac & Cardiovasc Surg, D-40225 Dusseldorf, Germany
[3] Univ Hosp, Inst Radiol, D-40225 Dusseldorf, Germany
[4] Soongsil Univ, Dept Mech Engn, Seoul 156743, South Korea
关键词
Blood flow; Human aorta; Extracorporeal circulation; Outlet boundary conditions; CFD; CURVED TUBE MODEL; PULSATILE FLOW; ATHEROSCLEROTIC LESIONS; NUMERICAL-SIMULATION; OSCILLATORY FLOW; ENTRANCE FLOW; UNSTEADY; CURVATURE; ARTERIAL; ARCH;
D O I
10.1016/j.apm.2010.12.022
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Blood flow in human aorta and its major branches is analyzed by computational fluid dynamics, for physiologic and extracorporeal circulation, the latter being the main focus. Mainly, a steady-state analysis is applied corresponding to extracorporeal circulation conditions. For physiologic circulation, pulsatile flow is also investigated. Distensibility of aorta walls is neglected. Blood is modeled as Newtonian fluid. The SST model is employed for turbulence in all cases, for a coherent treatment of the flows exhibiting Reynolds numbers encompassing the transitional regime. For modeling outlet boundary conditions, a simple model based on the prescription of loss coefficients is proposed, which is believed to be more favorable than some more straightforward techniques such as the prescription of an outlet pressure. For physiologic circulation, it is observed that the time-averaged velocity field of pulsatile flow does not show remarkable differences to steady-state results. For extracorporeal circulation, two cases, namely an antegrade and a retrograde perfusion are investigated. Flow patterns observed for the physiologic circulation and the extracorporeal circulation techniques show considerable differences. For extracorporeal circulation, much larger wall shear stress values are predicted. This indicates that mobilization of arteriosclerotic plaques needs to be considered as a very important issue for the extracorporeal circulation. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:3175 / 3188
页数:14
相关论文
共 39 条
[1]   FLOW PATTERNS AND SPATIAL-DISTRIBUTION OF ATHEROSCLEROTIC LESIONS IN HUMAN CORONARY-ARTERIES [J].
ASAKURA, T ;
KARINO, T .
CIRCULATION RESEARCH, 1990, 66 (04) :1045-1066
[2]  
Barth T. J., 1989, AIAA890366
[3]   Modelling turbulent flow past a circular cylinder by RANS, URANS, LES and DES [J].
Benim, A. C. ;
Pasqualotto, E. ;
Suh, S. H. .
PROGRESS IN COMPUTATIONAL FLUID DYNAMICS, 2008, 8 (05) :299-307
[4]   FLOW DYNAMICS IN THE HUMAN AORTA [J].
CHANDRAN, KB .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (04) :611-616
[5]   Calculation of unsteady flows in curved pipes [J].
Dwyer, HA ;
Cheer, AY ;
Rutaganira, T ;
Shacheraghi, N .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (04) :869-877
[6]   FLOW IN THE THORACIC AORTA [J].
FARTHING, S ;
PERONNEAU, P .
CARDIOVASCULAR RESEARCH, 1979, 13 (11) :607-620
[7]  
Fluent, 2006, US GUID VERS 6 3
[8]   CORRELATION AMONG SHEAR RATE MEASURES IN VASCULAR FLOWS [J].
FRIEDMAN, MH ;
DETERS, OJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1987, 109 (01) :25-26
[9]   The influence of the non-Newtonian properties of blood on the flow in large arteries:: unsteady flow in a 90° curved tube [J].
Gijsen, FJH ;
Allanic, E ;
van de Vosse, FN ;
Janssen, JD .
JOURNAL OF BIOMECHANICS, 1999, 32 (07) :705-713
[10]   FULLY-DEVELOPED PULSATILE FLOW IN A CURVED PIPE [J].
HAMAKIOTES, CC ;
BERGER, SA .
JOURNAL OF FLUID MECHANICS, 1988, 195 :23-55