Visual Outcomes, Footplate Position and Vault Achieved with the Visian Implantable Collamer Lens for Myopic Astigmatism

被引:18
作者
Reinstein, Dan Z. [1 ,2 ,3 ,4 ]
Vida, Ryan S. [1 ]
Archer, Timothy J. [1 ]
机构
[1] London Vis Clin, 138 Harley St, London W1G 7LA, England
[2] Columbia Univ, Med Ctr, New York, NY USA
[3] Sorbonne Univ, Paris, France
[4] Ulster Univ, Biomed Sci Res Inst, Coleraine, Londonderry, North Ireland
来源
CLINICAL OPHTHALMOLOGY | 2021年 / 15卷
关键词
implantable collamer lens; ICL; phakic IOL; footplate; VHF digital ultrasound; CILIARY SULCUS DIAMETER; ANTERIOR; SURGERY; REPRODUCIBILITY; OPTIMIZATION; ACCURACY; ARTEMIS; ICL;
D O I
10.2147/OPTH.S330879
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Report the outcomes of the implantable collamer lens (ICL) in myopic astigmatism using very high-frequency (VHF) digital ultrasound sizing. Methods: Analysis of 42 consecutive ICL procedures using EVO and EVO+ (Visian V4c) lenses (STAAR Surgical) was done. ICL size was chosen using the ultrasound-based Kojima Formula with Insight 100 VHF digital ultrasound (VHFDU). Standard visual outcomes analysis was performed using 3-month data, also including contrast sensitivity, refractive and corneal vector analysis, and ECC. Postoperative lens position was evaluated using VHF digital ultrasound. Results: Attempted SEQ was -10.83 +/- 3.39D (-4.40 to -16.98D). Cylinder was -1.46 +/- 1.15D (0.00 to -4.25D). One-year follow-up was available in 86% of the eyes and 3 months in 96%. Postoperative UDVA was 20/20 or better in 89% of the eyes, relative to 71% preoperatively. Postoperative SEQ refraction was +/- 0.50 D in 74% and +/- 1.00 D in 98% of the eyes. There was a gain of one line of CDVA in 43% of the eyes, 2 or more lines in 10% of the eyes, while there was a one line loss in 7% and no eyes lost 2 or more lines. The vector mean for the corneal SIA was 0.24 D Ax 100. Contrast sensitivity showed a statistically significant increase with a mean of 0.14 log units at 6, 12, and 18 cycles per degree (P<0.01). The mean change in ECC was -153 +/- 353 cells/mm(2). Lens vault was 506 +/- 233 mu m (114-924 mu m). Footplate insertion was in zonular position in 48.3%, ciliary body in 49.2%, and sulcus in 2.5% of locations. Conclusion: ICL implantation resulted in high safety and efficacy but with an implantation vault range that ideally would be improved upon. VHF digital ultrasound of the lens footplate and posterior anatomical relations may provide essential information for evaluating postoperative vault outliers.
引用
收藏
页码:4485 / 4497
页数:13
相关论文
共 33 条
  • [1] Astigmatism analysis by the Alpins method
    Alpins, N
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (01) : 31 - 49
  • [2] Outcomes after implantable collamer lens surgery in a Canadian cohort
    Chan, Aaron T.
    Zauberman, Noa A.
    Chan, Clara C.
    Rootman, David S.
    [J]. CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2017, 52 (02): : 150 - 154
  • [3] Ten-year clinical outcomes after implantation of a posterior chamber phakic intraocular lens for myopia
    Choi, Jae Hwan
    Lim, Dong Hui
    Nam, Seung Wan
    Yang, Chan Min
    Chung, Eui Sang
    Chung, Tae-Young
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (11) : 1555 - 1561
  • [4] Improving accuracy of phakic intraocular lens sizing using high-frequency ultrasound biomicroscopy
    Dougherty, Paul J.
    Rivera, Robert P.
    Schneider, David
    Lane, Stephen S.
    Brown, David
    Vukich, John
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (01) : 13 - 18
  • [5] Corneal endothelial assessment after ICL implantation
    Edelhauser, HF
    Sanders, DR
    Azar, R
    Lamielle, H
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (03) : 576 - 583
  • [6] Implantable collamer lens with central hole: 3-year follow-up
    Fernandez-Vega-Cueto, Luis
    Lisa, Carlos
    Esteve-Taboada, Jose J.
    Montes-Mico, Robert
    Alfonso, Jose F.
    [J]. CLINICAL OPHTHALMOLOGY, 2018, 12 : 2015 - 2029
  • [7] Comparison of corneal endothelial cell density and morphology after posterior chamber phakic intraocular lens implantation with and without a central hole
    Goukon, Hiroyasu
    Kamiya, Kazutaka
    Shimizu, Kimiya
    Igarashi, Akihito
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (11) : 1461 - 1465
  • [8] Clinical Outcomes and Cataract Formation Rates in Eyes 10 Years After Posterior Phakic Lens Implantation for Myopia
    Guber, Ivo
    Mouvet, Victoria
    Bergin, Ciara
    Perritaz, Sylvie
    Othenin-Girard, Philippe
    Majo, Francois
    [J]. JAMA OPHTHALMOLOGY, 2016, 134 (05) : 487 - 494
  • [9] Karandikar S, 2015, NEPAL J OPHTHALMOL, V7, P164, DOI 10.3126/nepjoph.v7i2.14967
  • [10] Correlation between ciliary sulcus diameter measured by 35 MHz ultrasound biomicroscopy and other ocular measurements
    Kim, Kyun-Hyung
    Shin, Hyung-Ho
    Kim, Hyo-Myung
    Song, Jong-Suk
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (04) : 632 - 637