Seismic response analysis of adjacent buildings connected with MR dampers

被引:114
作者
Bharti, S. D. [1 ]
Dumne, S. M. [1 ]
Shrimali, M. K. [1 ]
机构
[1] MNIT, Dept Struct Engn, Jaipur 302017, Rajasthan, India
关键词
Adjacent buildings; Coupled building control; Seismic response; MR damper; Control strategy; SEMIACTIVE CONTROL; MODEL;
D O I
10.1016/j.engstruct.2010.03.015
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The mutual impacts between two adjacent tall buildings during past major earthquakes have caused significant damage. Researchers have examined the effectiveness of various seismic control devices for interconnecting two adjacent buildings for earthquake hazard mitigation. In this study, the effectiveness of MR damper is examined for seismic response mitigation of adjacent multistory buildings under coupled building control scheme, involving passive-off, passive-on and semiactive control strategies. Further, the influence of damper location and maximum command voltage, on control performance is also examined. Based on the results of the numerical study it has been observed that the MR damper is an effective device to control the response of both the buildings for a wide range of ground motion. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2122 / 2133
页数:12
相关论文
共 29 条
[1]  
BHARTI SD, 2007, P 8 PAC C EARTHQ ENG
[2]   Optimum viscous damper for connecting adjacent SDOF structures for harmonic and stationary white-noise random excitations [J].
Bhaskararao, A. V. ;
Jangid, R. S. .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2007, 36 (04) :563-571
[3]   Seismic response of adjacent buildings connected with friction dampers [J].
Bhaskararao, A. V. ;
Jangid, R. S. .
BULLETIN OF EARTHQUAKE ENGINEERING, 2006, 4 (01) :43-64
[4]   Seismic analysis of structures connected with friction dampers [J].
Bhaskararao, AV ;
Jangid, RS .
ENGINEERING STRUCTURES, 2006, 28 (05) :690-703
[5]  
CAROLINA T, 2004, P 13 WORLD C EARTHQ
[6]  
DUMNE SM, 2007, P 8 PAC C EARTHQ ENG
[7]   An experimental study of MR dampers for seismic protection [J].
Dyke, SJ ;
Spencer, BF ;
Sain, MK ;
Carlson, JD .
SMART MATERIALS & STRUCTURES, 1998, 7 (05) :693-703
[8]   Semiactive control strategies for MR dampers: Comparative study [J].
Jansen, LM ;
Dyke, SJ .
JOURNAL OF ENGINEERING MECHANICS, 2000, 126 (08) :795-803
[9]  
Kim K., 2006, ENG STRUCT, V28, P83
[10]   SEMIACTIVE CONTROL FOR VIBRATION ATTENUATION [J].
LEITMANN, G .
JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 1994, 5 (06) :841-846