Genotoxicity and Cytotoxicity Comparison of Calcium Silicate-Based and Resin-Based Sealers on Human Periodontal Ligament Stem Cells

被引:5
|
作者
So, Bruna Barcelos [1 ]
Martins, Manoela Domingues [1 ]
So, Marcus Vinicius [1 ]
Weissheimer, Theodoro [1 ]
Marques, Marcia Martins [2 ]
Moreira, Maria Stella [2 ]
机构
[1] Fed Univ Rio Grande do Sul UFRGS, Dept Conservat Dent, Fac Dent, Porto Alegre, RS, Brazil
[2] Ibirapuera Univ UNIB, Dept Dent, Fac Dent, Sao Paulo, Brazil
来源
EUROPEAN ENDODONTIC JOURNAL | 2022年 / 7卷 / 02期
关键词
Biocompatibility; cytotoxicity; endodontic sealers; genotoxicity; ENDODONTIC SEALERS; APOPTOSIS; FLOW;
D O I
10.14744/eej.2022.09326
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: This study aimed to assess the genotoxicity and cytotoxicity of Sealer Plus BC (SBC), AH Plus (AHP) and MTA Fillapex (MTF). Methods: Human periodontal ligament dental stem cells (hPDLSCs) from third molars were isolated and cultured in a clonogenic medium. Cells were maintained in an incubator, and cell growth was monitored daily. hPDLSCs were characterised under flow cytometry and stem cell surface markers. The tested groups were a control group, SBC, AHP and MTF. Each sealer was prepared according to the manufacturer's instructions and placed in a clonogenic medium to produce a conditioned media. Conditioned media were then diluted to 10% to be placed in contact with culture cells in cell viability assay afterwards. The cells were harvested and plated into 96 wells culture plates. Genotoxicity was assessed by evaluation of micronucleus formation and cytotoxicity by MTT-based assay. All experiments were performed in triplicate. Data normality was verified by the Kolmogorov-Smirnov test. Statistical analysis for genotoxicity was performed with Kruskal-Wallis and Dunn's tests and two-way ANOVA for cytotoxicity, both with a significance level of 5%. Results: Cells expressed typical levels of mesenchymal stem cell surface markers. No differences in the number of micronuclei were observed among all groups (P>0.05). In all periods analysed (24, 48, and 72 h), the sealers presented statistically different results for cell viability (P<0.05), with SBC presenting the lowest cytotoxicity, followed by the control group, MTF, and AHP. Conclusion: All sealers presented low genotoxicity, and Sealer Plus BC presented the lowest cytotoxicity.
引用
收藏
页码:129 / 134
页数:6
相关论文
共 50 条
  • [31] The Effect of Heating Time and Temperature on Epoxy Resin and Calcium Silicate-based Endodontic Sealers
    Atmeh, Amre R.
    AlShwaimi, Emad
    JOURNAL OF ENDODONTICS, 2017, 43 (12) : 2112 - 2118
  • [32] Cytotoxicity and Genotoxicity of Epoxy Resin-Based Root Canal Sealers before and after Setting Procedures
    Kim, Mijoo
    Hayashi, Marc
    Yu, Bo
    Lee, Thomas K.
    Kim, Reuben H.
    Jo, Deuk-won
    LIFE-BASEL, 2022, 12 (06):
  • [33] Efficacy and retrievability of root canal filling using calcium silicate-based and epoxy resin-based root canal sealers with matched obturation techniques
    Kim, Seo Ryeong
    Kwak, Sang Won
    Lee, Ju-Kyung
    Goo, Hye-Jin
    Ha, Jung-Hong
    Kim, Hyeon-Cheol
    AUSTRALIAN ENDODONTIC JOURNAL, 2019, 45 (03) : 337 - 345
  • [34] A comparison of osteogenic effect of newly manufactured calcium silicate-based sealers in vitro
    Bae, Kkot-Byeol
    Choi, Yoorina
    Lee, Bin-Na
    Chang, Hoon-Sang
    Hwang, In-Nam
    Oh, Won-Mann
    Hwang, Yun-Chan
    DENTAL MATERIALS JOURNAL, 2023, 42 (06) : 860 - 867
  • [35] Biological interactions between calcium silicate-based endodontic biomaterials and periodontal ligament stem cells: A systematic review of in vitro studies
    Sanz, Jose Luis
    Guerrero-Girones, Julia
    Pecci-Lloret, Maria P.
    Pecci-Lloret, Miguel R.
    Melo, Maria
    INTERNATIONAL ENDODONTIC JOURNAL, 2021, 54 (11) : 2025 - 2043
  • [36] Influence of the final irrigation solution on the push-out bond strength of calcium silicate-based, epoxy resin-based and silicone-based endodontic sealers
    Donnermeyer, David
    Vahdat-Pajouh, Noushin
    Schaefer, Edgar
    Dammaschke, Till
    ODONTOLOGY, 2019, 107 (02) : 231 - 236
  • [37] The cytotoxic effects of resin-based sealers on dental pulp stem cells
    Trubiani, O.
    Caputi, S.
    Di Iorio, D.
    D'Amario, M.
    Paludi, M.
    Giancola, R.
    Di Maio, F. Di Nardo
    De Angelis, F.
    D'Arcangelo, C.
    INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (08) : 646 - 653
  • [38] Influence of the final irrigation solution on the push-out bond strength of calcium silicate-based, epoxy resin-based and silicone-based endodontic sealers
    David Donnermeyer
    Noushin Vahdat-Pajouh
    Edgar Schäfer
    Till Dammaschke
    Odontology, 2019, 107 : 231 - 236
  • [39] Cytotoxicity and Mineralization Potential of Four Calcium Silicate-Based Cements on Human Gingiva-Derived Stem Cells
    Lee, Donghee
    Park, Jun-Beom
    Song, Dani
    Kim, Hye-Min
    Kim, Sin-Young
    COATINGS, 2020, 10 (03)
  • [40] Calcium Silicate-Based Experimental Sealers: Physicochemical Properties Evaluation
    Zordan-Bronzel, Cristiane Lopes
    Tanomaru-Filho, Mario
    Chavez-Andrade, Gisselle Moraima
    Torres, Fernanda Ferrari Esteves
    Abi-Rached, Giselle Priscilla Cruz
    Guerreiro-Tanomaru, Juliane Maria
    MATERIALS RESEARCH-IBERO-AMERICAN JOURNAL OF MATERIALS, 2021, 24 (01):