Experimental validation of virtual absorbed energy of piezoelectric patch actuators in decentralized velocity feedback control of a plate

被引:6
作者
Yu, Yicheng [1 ]
Sun, Hongling [1 ]
Cao, Yin [1 ]
An, Fengyan [1 ]
Yang, Jun [1 ]
机构
[1] Chinese Acad Sci, Inst Acoust, Key Lab Noise & Vibrat Res, Beijing 100190, Peoples R China
基金
中国国家自然科学基金;
关键词
POWER ABSORPTION; KINETIC-ENERGY; NOISE; IMPLEMENTATION; EXCITATION; PANEL;
D O I
10.1016/j.jsv.2014.12.017
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Virtual absorbed energy of the piezoelectric patch actuator is a cost function for the optimal feedback gain which has been proved theoretically. Previously, simulations have shown that maximizing the virtual absorbed energy and minimizing the kinetic energy of the plate can obtain almost the same feedback gain. In this work, the performance of virtual absorbed energy is validated by experiments on the reduction of the vibration of a smart panel with decentralized control loops. Each control unit consists of a collocated piezoelectric patch actuator and accelerometer sensor with a single channel digital controller. The open loop sensor/actuator frequency response function with different physical parameters (such as dimensions of plate and actuator), has been analyzed numerically and experimentally, to enhance the stability of the control system. Since the system is not unconditionally stable, a digital phase lag compensator is designed to guarantee the stability for larger feedback gains. The stability of the multi-channel decentralized feedback control system has been assessed by the eigenvalue locus of the open loop transfer function matrix. The control effectiveness of the reduction of the panel kinetic energy has been assessed by error sensors. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 15
页数:15
相关论文
共 21 条
[1]  
Balas M. J., 1979, Journal of Guidance and Control, V2, P252, DOI 10.2514/3.55869
[2]   Active power minimization and power absorption in a plate with force and moment excitation [J].
Bardou, O ;
Gardonio, P ;
Elliott, SJ ;
Pinnington, RJ .
JOURNAL OF SOUND AND VIBRATION, 1997, 208 (01) :111-151
[3]  
Burke S. E., 1993, MECH SYSTEMS SIGNAL, V7, P765
[4]   Virtual absorbed energy in decentralized velocity feedback control of a plate with piezoelectric patch actuators [J].
Cao, Yin ;
Sun, Hongling ;
An, Fengyan ;
Li, Xiaodong .
APPLIED ACOUSTICS, 2013, 74 (06) :909-919
[5]   CHARACTERIZATION OF MULTIPLE PIEZOELECTRIC ACTUATORS FOR STRUCTURAL EXCITATION [J].
CLARK, RL ;
FULLER, CR ;
WICKS, A .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1991, 90 (01) :346-357
[6]  
Fuller C.R., 1996, ACTIVE CONTROL VIBRA
[7]   ACTIVE CONTROL OF SOUND RADIATION FROM A VIBRATING RECTANGULAR PANEL BY SOUND SOURCES AND VIBRATION INPUTS - AN EXPERIMENTAL COMPARISON [J].
FULLER, CR ;
HANSEN, CH ;
SNYDER, SD .
JOURNAL OF SOUND AND VIBRATION, 1991, 145 (02) :195-215
[8]   Smart panels for active structural acoustic control [J].
Gardonio, P ;
Elliott, SJ .
SMART MATERIALS AND STRUCTURES, 2004, 13 (06) :1314-1336
[9]   Modal response of a beam with a sensor-actuator pair for the implementation of velocity feedback control [J].
Gardonio, P ;
Elliott, SJ .
JOURNAL OF SOUND AND VIBRATION, 2005, 284 (1-2) :1-22
[10]  
Gardonio P, 2004, J SOUND VIB, V274, P163, DOI [10.1016/j.jsv.2003.05.004, 10.1016/j.sv.2003.05.004]