Critical parameters in blood processing for T-cell assays: Validation on ELISpot and tetramer platforms

被引:31
作者
Afonso, Georgia [1 ,2 ]
Scotto, Matthieu [1 ,2 ]
Renand, Amedee [3 ]
Arvastsson, Jeanette [4 ]
Vassilieff, Dominique [5 ]
Cilio, Corrado M. [4 ]
Mallone, Roberto [1 ,2 ]
机构
[1] St Vincent de Paul Hosp, INSERM, U986, DeAR Lab Avenir, F-75674 Paris 14, France
[2] Univ Paris 05, Fac Med Rene Descartes, Paris, France
[3] Hop Necker Enfants Malad, CNRS, UMR 8147, F-75743 Paris 15, France
[4] Lund Univ, Dept Clin Sci, Autoimmun Unit, CRC,UMAS, S-20502 Malmo, Sweden
[5] Cochin Hosp, Hematol Unit, F-75679 Paris 14, France
关键词
ELISpot; Peripheral blood mononuclear cells; T cell; Tetramer; CLASS-II TETRAMERS; IMMUNE-RESPONSES; HIV VACCINE; ANTIGEN; CD8(+); CD4(+); AUTOIMMUNITY; ACTIVATION; MECHANISM; CANCER;
D O I
10.1016/j.jim.2010.05.005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Assays detecting antigen (Ag)-specific T-cell responses in immune-mediated processes are increasingly employed to understand disease pathogenesis and "immune staging". The quantity and quality of starting peripheral blood mononuclear cell (PBMC) preparations are important factors in the performance of such assays. We therefore compared final PBMC yield and function by modifying parameters at the blood drawing, storage and processing steps. While drawing blood in vacuum-driven tubes or syringes and separating PBMCs on density gradients using standard or membrane (Leucosep (R)) tubes made no difference, storing tubes for 18 h without any agitation led to PBMC preparations contaminated with granulocytes and decreased interferon (IFN)-gamma enzyme-linked immunospot (ELISpot) responses. Even agitated blood showed a trend towards reduced ELISpot responses and increased human leukocyte Ag (HLA) multimer readouts when stored for 18 h compared to 3 h. These changes were reduced by diluting blood prior to storage. Washing PBMCs with media containing 10% human serum increased PBMC yields by 40.5%, without affecting ELISpot responses and multimer counts. However, washes with >10% human serum decreased multimer counts, with no additional improvement in PBMC yields. These findings may be relevant for optimizing and harmonizing PBMC processing procedures for T-cell assays. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:28 / 36
页数:9
相关论文
共 39 条
[1]   Phenotypic analysis of antigen-specific T lymphocytes [J].
Altman, JD ;
Moss, PAH ;
Goulder, PJR ;
Barouch, DH ;
McHeyzerWilliams, MG ;
Bell, JI ;
McMichael, AJ ;
Davis, MM .
SCIENCE, 1996, 274 (5284) :94-96
[2]   New generation vaccine induces effective melanoma-specific CD8+ T cells in the circulation but not in the tumor site [J].
Appay, Victor ;
Jandus, Camilla ;
Voelter, Verena ;
Reynard, Severine ;
Coupland, Sarah E. ;
Rimoldi, Donata ;
Lienard, Danielle ;
Guillaume, Philippe ;
Krieg, Arthur M. ;
Cerottini, Jean-Charles ;
Romero, Pedro ;
Leyvraz, Serge ;
Rufer, Nathalie ;
Speiser, Daniel E. .
JOURNAL OF IMMUNOLOGY, 2006, 177 (03) :1670-1678
[3]   Sensitive and viable identification of antigen-specific CD8+T cells by a flow cytometric assay for degranulation [J].
Betts, MR ;
Brenchley, JM ;
Price, DA ;
De Rosa, SC ;
Douek, DC ;
Roederer, M ;
Koup, RA .
JOURNAL OF IMMUNOLOGICAL METHODS, 2003, 281 (1-2) :65-78
[4]   The CIMT-monitoring panel:: a two-step approach to harmonize the enumeration of antigen-specific CD8+ T lymphocytes by structural and functional assays [J].
Britten, C. M. ;
Gouttefangeas, C. ;
Welters, M. J. P. ;
Pawelec, G. ;
Koch, S. ;
Ottensmeier, C. ;
Mander, A. ;
Walter, S. ;
Paschen, A. ;
Mueller-Berghaus, J. ;
Haas, I. ;
Mackensen, A. ;
Kollgaard, T. ;
thor Straten, P. ;
Schmitt, M. ;
Giannopoulos, K. ;
Maier, R. ;
Veelken, H. ;
Bertinetti, C. ;
Konur, A. ;
Huber, C. ;
Stevanovic, S. ;
Woelfel, T. ;
van der Burg, S. H. .
CANCER IMMUNOLOGY IMMUNOTHERAPY, 2008, 57 (03) :289-302
[5]   Toward the harmonization of immune monitoring in clinical trials: Quo vadis? [J].
Britten, C. M. ;
Janetzki, S. ;
van der Burg, S. H. ;
Gouttefangeas, C. ;
Hoos, A. .
CANCER IMMUNOLOGY IMMUNOTHERAPY, 2008, 57 (03) :285-288
[6]   Defining blood processing parameters for optimal detection of cryopreserved antigen-specific responses for HIV vaccine trials [J].
Bull, Marta ;
Lee, Deborah ;
Stucky, Jason ;
Chiu, Ya-Lin ;
Rubin, Abbe ;
Horton, Helen ;
McElrath, M. Juliana .
JOURNAL OF IMMUNOLOGICAL METHODS, 2007, 322 (1-2) :57-69
[7]   A live-cell assay to detect antigen-specific CD4+ T cells with diverse cytokine profiles [J].
Chattopadhyay, PK ;
Yu, J ;
Roederer, M .
NATURE MEDICINE, 2005, 11 (10) :1113-1117
[8]  
DE RR, 2005, J IMMUNOL METHODS, V297, P177
[9]   The good turned ugly:: immunopathogenic basis for diabetogenic CD8+ T cells in NOD mice [J].
DiLorenzo, TP ;
Serreze, DV .
IMMUNOLOGICAL REVIEWS, 2005, 204 :250-263
[10]   Maximizing the retention of antigen specific lymphocyte function after cryopreservation [J].
Disis, ML ;
dela Rosa, C ;
Goodell, V ;
Kuan, LY ;
Chang, JCC ;
Kuus-Reichel, K ;
Clay, TM ;
Lyerly, HK ;
Bhatia, S ;
Ghanekar, SA ;
Maino, VC ;
Maecker, HT .
JOURNAL OF IMMUNOLOGICAL METHODS, 2006, 308 (1-2) :13-18