Estimation of Membrane Hydration Status for Standby Proton Exchange Membrane Fuel Cell Systems by Impedance Measurement: First Results on Cell Characterization

被引:0
作者
Bidoggia, Benoit [1 ]
Kaer, Soren Knudsen [1 ]
机构
[1] Aalborg Univ, Dept Energy Technol, Aalborg, Denmark
来源
2011 IEEE 33RD INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE (INTELEC) | 2011年
关键词
Fuel cells; distributed power generation; unin-terruptible power systems; humidity measurement; impedance; RELATIVE-HUMIDITY; HUMIDIFICATION; CONDUCTIVITY; NAFION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Fuel cells have started replacing traditional lead battery banks in backup systems. Although these systems are characterized by long periods of standby, they must be able to start at any instant in the shortest time. In the case of low temperature proton exchange membrane fuel cell systems, a precise estimation of the fuel cells's membrane hydration status during standby is important for a fast and safe startup. In this article, the measurement of the complex impedance of the fuel cell is suggested as a method to estimate the membrane hydration status. A Nafion-based membrane electrode assembly has been fed with air whose temperature and relative humidity were controlled, and its complex impedance has been measured at different frequencies and for different values of the relative humidity. After characterizing the cell, a first approach in finding the relationship between relative humidity and complex impedance using exponential regression functions has been suggested. The results showed that measuring the impedance of a fuel cell can be a viable way for estimating the hydration status of its membrane before the system is started up.
引用
收藏
页数:7
相关论文
共 15 条
  • [1] Studies on ion-exchange membranes .1. Effect of humidity on the conductivity of Nafion(R)
    Anantaraman, AV
    Gardner, CL
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 414 (02): : 115 - 120
  • [2] Bidoggia B., 2008, INTELEC 2008, P1
  • [3] Humidity sensing properties of nafion and sol-gel derived SiO2/Nafion composite thin films
    Feng, CD
    Sun, SL
    Wang, H
    Segre, CU
    Stetter, JR
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1997, 40 (2-3) : 217 - 222
  • [4] Fuel cell based power system for backup applications: Telecom Italia and other field test results
    Gianolio, Giuseppe
    Rosso, Ilaria
    Cherchi, Pierpaolo
    Pedrazzo, Francesco
    Torrelli, Aristide
    Calzetti, Giuseppe
    Gamarino, Sergio
    [J]. INTELEC 07 - 29TH INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE, VOLS 1 AND 2, 2007, : 280 - +
  • [5] Symmetrical electrode mode for PEMFC characterisation using impedance spectroscopy
    Hombrados, AG
    González, L
    Rubio, MA
    Agila, W
    Villanueva, E
    Guinea, D
    Chinarro, E
    Moreno, B
    Jurado, JR
    [J]. JOURNAL OF POWER SOURCES, 2005, 151 : 25 - 31
  • [6] Study of external humidification method in proton exchange membrane fuel cell
    Hyun, D
    Kim, J
    [J]. JOURNAL OF POWER SOURCES, 2004, 126 (1-2) : 98 - 103
  • [7] Nordlund J., 2008, IEEE P INTELEC INT T, P1
  • [8] Identification and characterization of parameters for external humidification used in polymer electrolyte membrane fuel cells
    Rajalakshmi, N
    Sridhar, P
    Dhathathreyan, KS
    [J]. JOURNAL OF POWER SOURCES, 2002, 109 (02) : 452 - 457
  • [9] The hydrogen for base radio stations
    Rinaldi, P.
    Veca, G. M.
    [J]. INTELEC 07 - 29TH INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE, VOLS 1 AND 2, 2007, : 288 - 292
  • [10] Exploring the effects of symmetrical and asymmetrical relative humidity on the performance of H2/air PEM fuel cell at different temperatures
    Saleh, Mahmoud M.
    Okajima, Takeoshi
    Hayase, Masahiko
    Kitamura, Fusao
    Ohsaka, Takeo
    [J]. JOURNAL OF POWER SOURCES, 2007, 164 (02) : 503 - 509