Evaluation of Different Non-destructive Testing Methods to Detect Imperfections in Unidirectional Carbon Fiber Composite Ropes

被引:30
作者
Antin, Kim-Niklas [1 ]
Machado, Miguel A. [2 ]
Santos, Telmo G. [2 ]
Vilaca, Pedro [1 ]
机构
[1] Aalto Univ, Sch Engn, Dept Mech Engn, Espoo 02150, Finland
[2] NOVA Univ Lisbon, NOVA Sch Sci & Technol, Dept Mech & Ind Engn, UNIDEMI, P-2829516 Caparica, Portugal
关键词
Non-destructive testing; Ultrasonic; Eddy current; Carbon fiber; Composite; QUALITY-ASSURANCE; CFRP;
D O I
10.1007/s10921-019-0564-y
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Online monitoring of carbon fiber reinforced plastic (CFRP) ropes requires non-destructive testing (NDT) methods capable of detecting multiple damage types at high inspection speeds. Three NDT methods are evaluated on artificial and realistic imperfections in order to assess their suitability for online monitoring of CFRP ropes. To support testing, the microstructure and electrical conductivity of a carbon fiber rope is characterized. The compared methods are thermography via thermoelastic stress analysis, ultrasonic testing with commercial phased array transducers, and eddy current testing, supported by tailor-made probes. While thermoelastic stress analysis and ultrasonics proved to be accurate methods for detecting damage size and the shape of defects, they were found to be unsuitable for high-speed inspection of a CFRP rope. Instead, contactless inspection using eddy currents is a promising solution for real-time online monitoring of CFRP ropes at high inspection speeds.
引用
收藏
页数:12
相关论文
共 25 条
[1]   Advances in NDT and materials characterization by eddy currents [J].
Almeida, G. ;
Gonzalez, J. ;
Rosado, L. ;
Vilaca, P. ;
Santos, Telmo G. .
FORTY SIXTH CIRP CONFERENCE ON MANUFACTURING SYSTEMS 2013, 2013, 7 :359-364
[2]  
[Anonymous], 141251997 ISO
[3]  
[Anonymous], D562810 ASTM
[4]  
Antin KN., 2016, Conf. Proc. Soc. Exp. Mech. Ser, V3, P57, DOI DOI 10.1007/978-3-319-22446-6_7
[5]   Durability Performance and Service Life of CFCC Tendons Exposed to Elevated Temperature and Alkaline Environment [J].
Benmokrane, Brahim ;
Ali, Ahmed H. ;
Mohamed, Hamdy M. ;
Robert, Mathieu ;
ElSafty, Adel .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2016, 20 (01)
[6]   Application and reliability of a fiber optical surveillance system for a stay cable bridge [J].
Bronnimann, R ;
Nellen, PM ;
Sennhauser, U .
SMART MATERIALS & STRUCTURES, 1998, 7 (02) :229-236
[7]   Application of low frequency ECT method in noncontact detection and visualization of CFRP material [J].
Cheng, Jun ;
Qiu, Jinhao ;
Ji, Hongli ;
Wang, Enrong ;
Takagi, Toshiyuki ;
Uchimoto, Tetsuya .
COMPOSITES PART B-ENGINEERING, 2017, 110 :141-152
[8]   Role of interlaminar interface on bulk conductivity and electrical anisotropy of CFRP laminates measured by eddy current method [J].
Cheng, Jun ;
Ji, Hongli ;
Qiu, Jinhao ;
Takagi, Toshiyuki ;
Uchimoto, Tetsuya ;
Hu, Ning .
NDT & E INTERNATIONAL, 2014, 68 :1-12
[9]   Thermoelastic Stress Analysis of damage mechanisms in composite materials [J].
Emery, T. R. ;
Dulieu-Barton, J. M. .
COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2010, 41 (12) :1729-1742
[10]  
Freire J.L. F., 2015, J Mech Eng Autom, V5, P1, DOI DOI 10.17265/2159-5275/2015.11.005