Diffraction based overlay metrology:TB Accuracy and performance on front end stack

被引:19
作者
Leray, Philippe [1 ]
Cheng, Shaunee [1 ]
Kandel, Daniel [2 ]
Adel, Mike [2 ]
Marchelli, Anat [2 ]
Vakshtein, Irina [2 ]
Vasconi, Mauro [3 ]
Salski, Bartlomiej [4 ]
机构
[1] IMEC, Louvain, Belgium
[2] KLA Tencor Corp, IL-23100 Migdal Haemeq, Israel
[3] ST Microelect, Agrate Brianza, Italy
[4] QWED, Warsaw, Poland
来源
METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XXII, PTS 1 AND 2 | 2008年 / 6922卷 / 1-2期
关键词
overlay; scatterometry; differential signal; measurement uncertainty; precision; tool induced shift;
D O I
10.1117/12.772516
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The overlay metrology budget is typically 1/10 of the overlay control budget resulting in overlay metrology total measurement uncertainty requirements of 0.57nm for the most challenging use cases of the 32nm technology generation. Theoretical considerations show that overlay technology based on differential signal scatterometry (SCOL(TM)) has inherent advantages, which will allow it to achieve the 32nm technology generation requirements and go beyond it. In this work we present results of an experimental and theoretical study of SCOL. We present experimental results, comparing this technology with the standard imaging overlay metrology. In particular, we present performance results, such as precision and tool induced shift, for different target designs. The response to a large range of induced misalignment is also shown. SCOL performance on these targets for a real stack is reported. We also show results of simulations of the expected accuracy and performance associated with a variety of scatterometry overlay target designs. The simulations were carried out on several stacks including FEOL and BEOL materials. The inherent limitations and possible improvements of the SCOL technology are discussed. We show that with the appropriate target design and algorithms, scatterometry overlay achieves the accuracy required for future technology generations.
引用
收藏
页数:12
相关论文
共 8 条
[1]  
ADEL M, 2007, DOUBLE METROLOGY DOU
[2]  
[Anonymous], INT TECHN ROADM SEM
[3]   A new approach to pattern metrology [J].
Ausschnitt, CP .
METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XVIII, PTS 1 AND 2, 2004, 5375 :51-65
[4]   Light diffraction based overlay measurement [J].
Bischoff, J ;
Brunner, R ;
Bauer, J ;
Haak, U .
METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XV, 2001, 4344 :222-233
[5]   Scatterometry-gased overlay metrology [J].
Huang, HT ;
Raghavendra, G ;
Sezginer, A ;
Johnson, K ;
Stanke, F ;
Zimmerman, M ;
Cheung, C ;
Miyagi, M ;
Singh, B .
METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XVII, PTS 1 AND 2, 2003, 5038 :126-137
[6]  
KANDEL D, 2007, P SPIE, V6616
[7]   Improved CD and overlay metrology using an optical Fourier transform instrument [J].
Petit, J ;
Boher, P ;
Leroux, T ;
Barritault, P ;
Hazart, J ;
Chaton, P .
METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XIX, PTS 1-3, 2005, 5752 :420-428
[8]   A novel diffraction based spectroscopic method for overlay metrology [J].
Yang, WD ;
Lowe-Webb, R ;
Rabello, S ;
Hu, JT ;
Lin, JY ;
Heaton, J ;
Dusa, M ;
den Boef, A ;
van der Schaar, M ;
Hunter, A .
METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XVII, PTS 1 AND 2, 2003, 5038 :200-207