Diffusion Coefficient Measurement Using a Temperature-Controlled Fluid for Quality Control in Multicenter Studies

被引:121
作者
Chenevert, Thomas L. [1 ]
Galban, Craig J. [1 ]
Ivancevic, Marko K. [1 ,2 ]
Rohrer, Susan E. [1 ]
Londy, Frank J. [1 ]
Kwee, Thomas C. [1 ]
Meyer, Charles R. [1 ]
Johnson, Timothy D. [3 ]
Rehemtulla, Alnawaz [4 ]
Ross, Brian D. [1 ]
机构
[1] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
[2] Philips Healthcare, Cleveland, OH USA
[3] Univ Michigan, Dept Biostat, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
基金
美国国家卫生研究院;
关键词
diffusion; MRI; phantom; ice water; quality control; SELF-DIFFUSION; BRAIN-TUMOR; WATER; ANISOTROPY; LIQUIDS; PHANTOM; CANCER; VALUES; NECK; HEAD;
D O I
10.1002/jmri.22363
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To present the use of a quality control ice-water phantom for diffusion-weighted magnetic resonance imaging (DW-MRI). DW-MRI has emerged as an important cancer imaging biomarker candidate for diagnosis and early treatment response assessment. Validating imaging biomarkers through multicenter trials requires calibration and performance testing across sites. Materials and Methods: The phantom consisted of a center tube filled with distilled water surrounded by ice water. Following preparation of the phantom, approximate to 30 minutes was allowed to reach thermal equilibrium. DW-MRI data were collected at seven institutions, 20 MRI scanners from three vendors, and two field strengths (1.5 and 3T). The phantom was also scanned on a single system on 16 different days over a. 25-day period. All data were transferred to a central processing site at the University of Michigan for analysis. Results: Results revealed that the variation of measured apparent diffusion coefficient (ADC) values between all systems tested was +/-5%, indicating excellent agreement between systems. Reproducibility of a single system over a 25-day period was also found to be within +/-5% ADC values. Overall, the use of an ice-water phantom for assessment of ADC was found to be a reasonable candidate for use in multicenter trials. Conclusion: The ice-water phantom described here is a practical and universal approach to validate the accuracy of ADC measurements with ever changing MRI sequence and hardware design and can be readily implemented in multicenter clinical trial designs.
引用
收藏
页码:983 / 987
页数:5
相关论文
共 22 条
[1]   Diffusion-Weighted Magnetic Resonance Imaging as a Cancer Biomarker: Consensus and Recommendations [J].
不详 .
NEOPLASIA, 2009, 11 (02) :102-125
[2]   Diffusion Imaging for Therapy Response Assessment of Brain Tumor [J].
Chenevert, Thomas L. ;
Ross, Brian D. .
NEUROIMAGING CLINICS OF NORTH AMERICA, 2009, 19 (04) :559-+
[3]  
Clark CA, 2000, MAGN RESON MED, V44, P852, DOI 10.1002/1522-2594(200012)44:6<852::AID-MRM5>3.0.CO
[4]  
2-A
[5]   PROPERTIES OF WATER IN BIOLOGICAL-SYSTEMS [J].
COOKE, R ;
KUNTZ, ID .
ANNUAL REVIEW OF BIOPHYSICS AND BIOENGINEERING, 1974, 3 :95-126
[6]   Developing a quality control protocol for diffusion imaging on a clinical MRI system [J].
Delakis, I ;
Moore, EM ;
Leach, MO ;
De Wilde, JP .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (08) :1409-1422
[7]   A Feasibility Study of Parametric Response Map Analysis of Diffusion-Weighted Magnetic Resonance Imaging Scans of Head and Neck Cancer Patients for Providing Early Detection of Therapeutic Efficacy [J].
Galban, Craig J. ;
Mukherji, Suresh K. ;
Chenevert, Thomas L. ;
Meyer, Charles R. ;
Hamstra, Daniel A. ;
Bland, Peyton H. ;
Johnson, Timothy D. ;
Moffat, Bradford A. ;
Rehemtulla, Alnawaz ;
Eisbruch, Avraham ;
Ross, Brian D. .
TRANSLATIONAL ONCOLOGY, 2009, 2 (03) :184-190
[8]   Diffusion Magnetic Resonance Imaging: An Imaging Treatment Response Biomarker to Chemoradiotherapy in a Mouse Model of Squamous Cell Cancer of the Head and Neck [J].
Hamstra, Daniel A. ;
Lee, Kuei C. ;
Moffat, Bradford A. ;
Chenevert, Thomas L. ;
Rehemtulla, Alnawaz ;
Ross, Brian D. .
TRANSLATIONAL ONCOLOGY, 2008, 1 (04) :187-194
[9]   Temperature-dependent self-diffusion coefficients of water and six selected molecular liquids for calibration in accurate 1H NMR PFG measurements [J].
Holz, M ;
Heil, SR ;
Sacco, A .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2000, 2 (20) :4740-4742
[10]   Detection of microscopic anisotropy in gray matter and in a novel tissue phantom using double Pulsed Gradient Spin Echo MR [J].
Komlosh, M. E. ;
Horkay, F. ;
Freldlin, R. Z. ;
Nevo, U. ;
Assaf, Y. ;
Basser, P. J. .
JOURNAL OF MAGNETIC RESONANCE, 2007, 189 (01) :38-45