Improvements in Multislice Parallel Imaging Using Radial CAIPIRINHA

被引:53
作者
Yutzy, Stephen R. [2 ,3 ]
Seiberlich, Nicole
Duerk, Jeffrey L. [2 ]
Griswold, Mark A. [1 ]
机构
[1] Univ Hosp Cleveland, Dept Radiol, CCRI, MRI, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[3] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA 15260 USA
基金
美国国家卫生研究院;
关键词
parallel imaging; multi-slice; radial; CAIPIRINHA; K-SPACE TRAJECTORIES; MR IMAGES; GRAPPA; ACQUISITION; EXCITATION;
D O I
10.1002/mrm.22752
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Multislice parallel imaging involves the simultaneous sampling of multiple parallel slices which are subsequently separated using parallel imaging reconstruction. The CAIPIRINHA technique improves this reconstruction by manipulating the phase of the RF excitation pulses to shift the aliasing pattern such that there is less aliasing energy to be reconstructed. In this work, it is shown that combining the phase manipulation used in CAIPIRINHA with a non-Cartesian (radial) sampling scheme further decreases the aliasing energy for the parallel imaging algorithm to reconstruct, thereby further increasing the degree to which a multi-channel receiver array can be utilized for parallel imaging acceleration. In radial CAIPIRINHA, individual bands (slices) in a multislice excitation are modulated with view-dependent phase, causing a destructive interference of entire slices. This destructive interference leads to a reduction in aliasing compared to the coherent shifts one observes when using this same technique with a Cartesian trajectory. Recovery of each individual slice is possible because the applied phase pattern is known, and a conjugate-gradient reconstruction algorithm minimizes the contributions from other slices. Results are presented with a standard 12-channel head coil with acceleration factors up to 14, where radial CAIPIRINHA produces an improved reconstruction when compared with Cartesian CAIPIRINHA. Magn Reson Med 65:1630-1637, 2011. (C)2011 Wiley-Liss, Inc.
引用
收藏
页码:1630 / 1637
页数:8
相关论文
共 23 条
  • [1] 2D-GRAPPA-operator for faster 3D parallel MRI
    Blaimer, Martin
    Breuer, Felix A.
    Mueller, Matthias
    Seiberlich, Nicole
    Ebel, Dmitry
    Heidemann, Robin M.
    Griswold, Mark A.
    Jakob, Peter M.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (06) : 1359 - 1364
  • [2] Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging
    Breuer, FA
    Blaimer, M
    Heidemann, RM
    Mueller, MF
    Griswold, MA
    Jakob, PM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (03) : 684 - 691
  • [3] General Formulation for Quantitative G-factor Calculation in GRAPPA Reconstructions
    Breuer, Felix A.
    Kannengiesser, Stephan A. R.
    Blaimer, Martin
    Seiberlich, Nicole
    Jakob, Peter M.
    Griswold, Mark A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (03) : 739 - 746
  • [4] High-order multibland encoding in the heart
    Cunningham, CH
    Wright, GA
    Wood, ML
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) : 689 - 698
  • [5] Cunningham CH, 1999, MAGNET RESON MED, V42, P577, DOI 10.1002/(SICI)1522-2594(199909)42:3<577::AID-MRM21>3.0.CO
  • [6] 2-E
  • [7] Nonuniform fast Fourier transforms using min-max interpolation
    Fessler, JA
    Sutton, BP
    [J]. IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2003, 51 (02) : 560 - 574
  • [8] Wavelet encoding for improved SNR and retrospective slice thickness adjustment
    Gelman, N
    Wood, ML
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (03) : 383 - 391
  • [9] Wavelet encoding for 3D gradient-echo MR imaging
    Gelman, N
    Wood, ML
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) : 613 - 619
  • [10] PHASE-OFFSET MULTIPLANAR (POMP) VOLUME IMAGING - A NEW TECHNIQUE
    GLOVER, GH
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (04): : 457 - 461