Semi-micro ion chromatography of iodide in seawater

被引:45
作者
Ito, K [1 ]
机构
[1] Hiroshima Univ, Fac Engn, Dept Environm Sci, Higashihiroshima 7398527, Japan
关键词
sea water; analyte focusing; on-column; matrix elimination; iodide;
D O I
10.1016/S0021-9673(98)00910-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Large sample volume injections including both on-column analyte focusing and on-column matrix elimination techniques were examined for semi-micro ion chromatography of trace iodide (I-) in seawater. A semi-microcolumn (35x1 mm I.D.) packed with styrene-divinylbenzene copolymer with high anion-exchange capacity and a mobile phase of 0.03 M NaClO4+0.5 M NaCl+5 mM sodium phosphate buffer, pH 6.0, was used. Iodide in seawater was effectively concentrated on the column by both electrostatic and hydrophobic interactions and was eluted without peak broadening. ClO4- (NaClO4) in the mobile phase was effective for the elution of iodide and Cl- (NaCl) for both the concentration of iodide (I-) with hydrophobicity and the removal of interference by the major anions. An excess of major anions in seawater did not disturb the detection of iodide at UV 226 nm. The relative standard deviations for successive injections of 5 and 1 mu g/l I- (2 ml of 35% artificial seawater) were 1.5 and 5.8% (n=5, each), respectively. The slope of calibration curve (by peak area) using the semi-microcolumn was similar to 2.8-times higher than that for a conventional column with the same resin (150x4.6 mm I.D.) The present method had a detection limit of 0.2 mu g/l I- for 2 ml of 35% artificial seawater and was successfully applied to seawater samples. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:211 / 217
页数:7
相关论文
共 22 条
[1]   MATRIX-ELIMINATION ION CHROMATOGRAPHY WITH POSTCOLUMN REACTION DETECTION FOR THE DETERMINATION OF IODIDE IN SALINE WATERS [J].
BRANDAO, ACM ;
BUCHBERGER, WW ;
BUTLER, ECV ;
FAGAN, PA ;
HADDAD, PR .
JOURNAL OF CHROMATOGRAPHY A, 1995, 706 (1-2) :271-275
[2]  
BREWER PG, 1975, CHEM OCEANOGRAPHY, V1, pCH7
[3]   Z-SHAPED FLOW CELL FOR UV-DETECTION IN CAPILLARY ELECTROPHORESIS [J].
CHERVET, JP ;
VANSOEST, REJ ;
URSEM, M .
JOURNAL OF CHROMATOGRAPHY, 1991, 543 (02) :439-449
[4]  
HADDAD PR, 1991, J CHROMATOGR, V546, P221
[5]   DETERMINATION OF INORGANIC ANIONS IN SALT-SOLUTIONS BY ION CHROMATOGRAPHY USING C18 REVERSED-PHASE COLUMNS COATED WITH CETYLTRIMETHYLAMMONIUM [J].
ITO, K ;
ARIYOSHI, Y ;
SUNAHARA, H .
JOURNAL OF CHROMATOGRAPHY, 1992, 598 (02) :237-241
[6]   ANION CHROMATOGRAPHY USING OCTADECYLSILANE REVERSED-PHASE COLUMNS COATED WITH CETYLTRIMETHYLAMMONIUM AND ITS APPLICATION TO NITRITE AND NITRATE IN SEAWATER [J].
ITO, K ;
ARIYOSHI, Y ;
TANABIKI, F ;
SUNAHARA, H .
ANALYTICAL CHEMISTRY, 1991, 63 (03) :273-276
[7]   ION CHROMATOGRAPHY WITH ULTRAVIOLET AND AMPEROMETRIC DETECTION FOR IODIDE AND THIOCYANATE IN CONCENTRATED SALT-SOLUTIONS [J].
ITO, K ;
SUNAHARA, H .
JOURNAL OF CHROMATOGRAPHY, 1990, 502 (01) :121-129
[8]   ION CHROMATOGRAPHY OF INORGANIC IODINE SPECIES USING C-18 REVERSED-PHASE COLUMNS COATED WITH CETYLTRIMETHYLAMMONIUM [J].
ITO, K ;
SHOTO, E ;
SUNAHARA, H .
JOURNAL OF CHROMATOGRAPHY, 1991, 549 (1-2) :265-272
[9]   Determination of iodide in seawater by ion chromatography [J].
Ito, K .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3628-3632
[10]  
ITO K, 1988, BUNSEKI KAGAKU, V37, P292