The design of the multiplexing data acquisition and monitoring system for magneto cardio graphy(MCG)
被引:0
作者:
Chang, WS
论文数: 0引用数: 0
h-index: 0
机构:
Korea Electrotechnol Res Inst, Electromagnet Med Device Res Ctr, Ansan 426901, Gyeonggi Do, South KoreaKorea Electrotechnol Res Inst, Electromagnet Med Device Res Ctr, Ansan 426901, Gyeonggi Do, South Korea
Chang, WS
[1
]
Jeon, CI
论文数: 0引用数: 0
h-index: 0
机构:
Korea Electrotechnol Res Inst, Electromagnet Med Device Res Ctr, Ansan 426901, Gyeonggi Do, South KoreaKorea Electrotechnol Res Inst, Electromagnet Med Device Res Ctr, Ansan 426901, Gyeonggi Do, South Korea
Jeon, CI
[1
]
Park, YH
论文数: 0引用数: 0
h-index: 0
机构:
Korea Electrotechnol Res Inst, Electromagnet Med Device Res Ctr, Ansan 426901, Gyeonggi Do, South KoreaKorea Electrotechnol Res Inst, Electromagnet Med Device Res Ctr, Ansan 426901, Gyeonggi Do, South Korea
Park, YH
[1
]
Yang, SK
论文数: 0引用数: 0
h-index: 0
机构:
Korea Electrotechnol Res Inst, Electromagnet Med Device Res Ctr, Ansan 426901, Gyeonggi Do, South KoreaKorea Electrotechnol Res Inst, Electromagnet Med Device Res Ctr, Ansan 426901, Gyeonggi Do, South Korea
Yang, SK
[1
]
Oh, SK
论文数: 0引用数: 0
h-index: 0
机构:
Korea Electrotechnol Res Inst, Electromagnet Med Device Res Ctr, Ansan 426901, Gyeonggi Do, South KoreaKorea Electrotechnol Res Inst, Electromagnet Med Device Res Ctr, Ansan 426901, Gyeonggi Do, South Korea
Oh, SK
[1
]
Huh, Y
论文数: 0引用数: 0
h-index: 0
机构:
Korea Electrotechnol Res Inst, Electromagnet Med Device Res Ctr, Ansan 426901, Gyeonggi Do, South KoreaKorea Electrotechnol Res Inst, Electromagnet Med Device Res Ctr, Ansan 426901, Gyeonggi Do, South Korea
Huh, Y
[1
]
机构:
[1] Korea Electrotechnol Res Inst, Electromagnet Med Device Res Ctr, Ansan 426901, Gyeonggi Do, South Korea
来源:
TENCON 2004 - 2004 IEEE REGION 10 CONFERENCE, VOLS A-D, PROCEEDINGS: ANALOG AND DIGITAL TECHNIQUES IN ELECTRICAL ENGINEERING
|
2004年
关键词:
D O I:
暂无
中图分类号:
TP18 [人工智能理论];
学科分类号:
081104 ;
0812 ;
0835 ;
1405 ;
摘要:
The electrical current generated by heart creates not only electric potential but also a magnetic field. In this paper, we have designed the multiplexing data acquisition system for multi channel bio-magnetic signal measurement. The system consists of VXI rack that is organized MUX and AD board, Industrial rack that is mounted single board computer and DSP board. This system enables to real time monitoring of multi channel data simultaneously. The number of channel could be increased simply added each module and firmware could be upgraded easily using host port interface of DSP.