Development of a transmission alpha particle dosimetry technique using A549 cells and a Ra-223 source for targeted alpha therapy

被引:10
作者
Al Darwish, R. [1 ,2 ]
Staudacher, A. H. [3 ,4 ,5 ]
Li, Y. [6 ,7 ]
Brown, M. P. [3 ,4 ,5 ,8 ]
Bezak, E. [2 ,6 ,9 ]
机构
[1] Royal Adelaide Hosp, Dept Med Phys, Adelaide, SA 5000, Australia
[2] Univ Adelaide, Sch Phys Sci, Adelaide, SA 5005, Australia
[3] SA Pathol, Ctr Canc Biol, Translat Oncol Lab, Adelaide, SA 5001, Australia
[4] Univ South Australia, Adelaide, SA 5001, Australia
[5] Univ Adelaide, Sch Med, Adelaide, SA 5005, Australia
[6] Univ South Australia, Sansom Inst, Int Ctr Allied Hlth Evidence, Adelaide, SA 5001, Australia
[7] Univ South Australia, Sansom Inst, Adelaide, SA 5001, Australia
[8] Royal Adelaide Hosp, Canc Clin Trials Unit, Adelaide, SA 5000, Australia
[9] Univ South Australia, Sansom Inst Hlth Res, Adelaide, SA 5001, Australia
关键词
targeted alpha therapy; Timepix; dosimetry; A549; cells; gamma-H2AX; RELATIVE BIOLOGICAL EFFECTIVENESS; X-RAY; IONIZING-RADIATION; TIMEPIX; ENERGY; CAMERA; RADIOBIOLOGY; RADIUM-223; SURVIVAL; DETECTOR;
D O I
10.1118/1.4965805
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In targeted radionuclide therapy, regional tumors are targeted with radionuclides delivering therapeutic radiation doses. Targeted alpha therapy (TAT) is of particular interest due to its ability to deliver alpha particles of high linear energy transfer within the confines of the tumor. However, there is a lack of data related to alpha particle distribution in TAT. These data are required to more accurately estimate the absorbed dose on a cellular level. As a result, there is a need for a dosimeter that can estimate, or better yet determine the absorbed dose deposited by alpha particles in cells. In this study, as an initial step, the authors present a transmission dosimetry design for alpha particles using A549 lung carcinoma cells, an external alpha particle emitting source (radium 223; Ra-223) and a Timepix pixelated semiconductor detector. Methods: The dose delivery to the A549 lung carcinoma cell line from a Ra-223 source, considered to be an attractive radionuclide for alpha therapy, was investigated in the current work. A549 cells were either unirradiated (control) or irradiated for 1/2, 1, 2, or 3 h with alpha particles emitted from a Ra-223 source positioned below a monolayer of A549 cells. The Timepix detector was used to determine the number of transmitted alpha particles passing through the A549 cells and DNA double strand breaks (DSBs) in the form of gamma-H2AX foci were examined by fluorescence microscopy. The number of transmitted alpha particles was correlated with the observed DNA DSBs and the delivered radiation dose was estimated. Additionally, the dose deposited was calculated using Monte Carlo code SRIM. Results: Approximately 20% of alpha particles were transmitted and detected by Timepix. The frequency and number of gamma-H2AX foci increased significantly following alpha particle irradiation as compared to unirradiated controls. The equivalent dose delivered to A549 cells was estimated to be approximately 0.66, 1.32, 2.53, and 3.96 Gy after 1/2, 1, 2, and 3 h irradiation, respectively, considering a relative biological effectiveness of alpha particles of 5.5. Conclusions: The study confirmed that the Timepix detector can be used for transmission alpha particle dosimetry. If cross-calibrated using biological dosimetry, this method will give a good indication of the biological effects of alpha particles without the need for repeated biological dosimetry which is costly, time consuming, and not readily available. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:6145 / 6153
页数:9
相关论文
共 44 条
[1]  
Agency A. E., 2000, ABSORBED DOSE DETERM
[2]   A hybrid photodetector using the Timepix semiconductor assembly for photoelectron detection [J].
Anton, Gisela ;
Gebert, Ulrike ;
Michel, Thilo ;
Ruegheimer, Tilman K. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 602 (01) :205-208
[3]   The α-Camera: A Quantitative Digital Autoradiography Technique Using a Charge-Coupled Device for Ex Vivo High-Resolution Bioimaging of α-Particles [J].
Back, Tom ;
Jacobsson, Lars .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (10) :1616-1623
[4]   Measurement of pattern recognition efficiency of tracks generated by ionizing radiation in a Medipix2 device [J].
Bouchami, J. ;
Gutierrez, A. ;
Holy, T. ;
Houdayer, A. ;
Jakubek, J. ;
Lebel, C. ;
Leroy, C. ;
Macana, J. ;
Martin, J. -P. ;
Pospisil, S. ;
Prak, S. ;
Sabella, P. ;
Teyssier, C. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 :S187-S189
[5]   What is the role of the Bystander response in radionuclide therapies? [J].
Brady, Darren ;
O'Sullivan, Joe M. ;
Prise, Kevin M. .
FRONTIERS IN ONCOLOGY, 2013, 3
[6]   High-linear energy transfer irradiation targeted to skeletal metastases by the α-emitter 223Ra:: Adjuvant or alternative to conventional modalities? [J].
Bruland, Oyvind S. ;
Nilsson, Sten ;
Fisher, Darrell R. ;
Larsen, Roy H. .
CLINICAL CANCER RESEARCH, 2006, 12 (20) :6250S-6257S
[7]  
Campbell M., 2007, NUCL SCI S C REC NSS
[8]  
CERN, 2011, MED, V2011
[9]   Ex Vivo Activity Quantification in Micrometastases at the Cellular Scale Using the α-Camera Technique [J].
Chouin, Nicolas ;
Lindegren, Sture ;
Frost, Sofia H. L. ;
Jensen, Holger ;
Albertsson, Per ;
Hultborn, Ragnar ;
Palm, Stig ;
Jacobsson, Lars ;
Back, Tom .
JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (08) :1347-1353
[10]  
Cognetta Jr AB, 2013, RAD THERAPY SKIN CAN