Step-scan FT-IR time-resolved spectroscopy in the solid state

被引:19
|
作者
Smith, GD [1 ]
Hutson, MS [1 ]
Lu, Y [1 ]
Tierney, MT [1 ]
Grinstaff, MW [1 ]
Palmer, RA [1 ]
机构
[1] Duke Univ, PM Gross Chem Lab, Durham, NC 27708 USA
关键词
KBr pellet; time-resolved; step-scan FT-IR; polypyridine transition metal complexes; solid state;
D O I
10.1366/0003702011952262
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The use of KBr pellets as an interference-free matrix for performing time-resolved infrared (TR-IR) measurements on samples in their crystalline state is described and demonstrated. Step-scan Fourier transform infrared time-resolved spectroscopy ((SFT)-F-2-IR TRS) is used to measure the infrared (IR) absorption difference (DeltaA, excited state minus ground state) spectra of the Long-lived chargetransfer excited states of polypyridine Ru(II) and Pt(II) complexes pressed into KBr pellets. A comparison of the difference spectra measured for the metal-to-ligand charge-transfer ((MLCT)-M-3) state of the Ru(II) complex in a KBr pellet vs. acetonitrile (ACN) solution is used to validate the technique, The Pt(II) complex could not be analyzed in solution because of its extremely poor solubility. Thus, these results illustrate one of the significant advantages of performing TR-IR measurements on solid KBr sample pellets.
引用
收藏
页码:637 / 642
页数:6
相关论文
共 50 条
  • [1] Time-Resolved Step-Scan FT-IR Spectroscopy of the Photodynamics of Carbonmonoxymyoglobin
    Department of Chemistry, Duke University, Box 90346, Durham
    NC
    27708-0346, United States
    不详
    27709, United States
    不详
    MA
    01821, United States
    Appl Spectrosc, 6 (702-708):
  • [2] Errors and artifacts in time-resolved step-scan FT-IR spectroscopy
    Rödig, C
    Siebert, F
    APPLIED SPECTROSCOPY, 1999, 53 (08) : 893 - 901
  • [4] TIME-RESOLVED STEP-SCAN FT-IR SPECTROSCOPY OF THE PHOTODYNAMICS OF CARBONMONOXYMYOGLOBIN
    PLUNKETT, SE
    CHAO, JL
    TAGUE, TJ
    PALMER, RA
    APPLIED SPECTROSCOPY, 1995, 49 (06) : 702 - 708
  • [5] Time-resolved step-scan FT-IR spectroscopy: Focus on multivariate curve resolution
    Ruckebusch, C
    Duponchel, L
    Sombret, B
    Huvenne, JP
    Saurina, J
    JOURNAL OF CHEMICAL INFORMATION AND COMPUTER SCIENCES, 2003, 43 (06): : 1966 - 1973
  • [6] TIME-RESOLVED FT-IR ABSORPTION-SPECTROSCOPY USING A STEP-SCAN INTERFEROMETER
    UHMANN, W
    BECKER, A
    TARAN, C
    SIEBERT, F
    APPLIED SPECTROSCOPY, 1991, 45 (03) : 390 - 397
  • [7] Time-resolved study of acetyl radical in zeolite NaY by step-scan FT-IR spectroscopy
    Vasenkov, S
    Frei, H
    JOURNAL OF PHYSICAL CHEMISTRY A, 2000, 104 (18): : 4327 - 4332
  • [8] Time-resolved impulse photoacoustic measurements by step-scan FT-IR spectrometry
    Budevska, BO
    Manning, CJ
    APPLIED SPECTROSCOPY, 1996, 50 (07) : 939 - 947
  • [9] Study of impulse polymer rheo-optics by step-scan FT-IR time-resolved spectroscopy
    Wang, HC
    Palmer, RA
    Manning, CJ
    APPLIED SPECTROSCOPY, 1997, 51 (08) : 1245 - 1250
  • [10] Study of impulse polymer rheo-optics by step-scan FT-IR time-resolved spectroscopy
    Duke Univ, Durham, United States
    Appl Spectrosc, 8 (1245-1250):