Effect of dependent scattering on the optical properties of Intralipid tissue phantoms

被引:42
作者
Di Ninni, Paola [1 ]
Martelli, Fabrizio [1 ]
Zaccanti, Giovanni [1 ]
机构
[1] Univ Florence, Dipartimento Fis & Astron, I-50019 Florence, Italy
关键词
DIFFUSE-REFLECTANCE SPECTROSCOPY; ABSORPTION-COEFFICIENTS; SIMULATING PHANTOMS; FREQUENCY-DOMAIN; NIR WAVELENGTHS; MEDIA; CALIBRATION; MIGRATION;
D O I
10.1364/BOE.2.002265
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The calibration of optical tissue-simulating phantoms remains an open question in spite of the many techniques proposed for accurate measurements of optical properties. As a consequence, a reference phantom with well known optical properties is still missing. As a first step towards a reference phantom we have recently proposed to use dilutions of Intralipid 20%. In this paper we discuss a matter that is commonly ignored when dilutions are prepared, i.e., the possibility of deviations from the simple linear relationships between the optical properties of the dilution and the Intralipid concentration due to the effects of dependent scattering. The results of an experimental investigation showed that dependent scattering does not affect absorption. As for the reduced scattering coefficient the effect can be described adding a term proportional to the square of the concentration. However, for concentrations of interest for tissue optics deviations from linearity remain within about 2%. The experimental investigation also showed that the microphysical properties of Intralipid are not affected by dilution. These results show the possibility to easily obtain a liquid diffusive phantom whose optical properties are known with error smaller than about 1%. Due to the intrinsic limitations of the different techniques proposed for measuring the optical properties it seems difficult to obtain a similar accuracy for solid phantoms. (C) 2011 Optical Society of America
引用
收藏
页码:2265 / 2278
页数:14
相关论文
共 28 条
[1]   Improved accuracy in time-resolved diffuse reflectance spectroscopy [J].
Alerstam, Erik ;
Andersson-Engels, Stefan ;
Svensson, Tomas .
OPTICS EXPRESS, 2008, 16 (14) :10440-10454
[2]  
Bohren C.F, 2008, Absorption and Scattering of Light by Small Particles
[3]   Reference optical phantoms for diffuse optical spectroscopy. Part 1-Error analysis of a time resolved transmittance characterization method [J].
Bouchard, Jean-Pierre ;
Veilleux, Israel ;
Jedidi, Rym ;
Noiseux, Isabelle ;
Fortin, Michel ;
Mermut, Ozzy .
OPTICS EXPRESS, 2010, 18 (11) :11495-11507
[4]   A primary method for determination of optical parameters of turbid samples and application to intralipid between 550 and 1630nm [J].
Chen, Cheng ;
Lu, Jun Q. ;
Ding, Huafeng ;
Jacobs, Kenneth M. ;
Du, Yong ;
Hu, Xin-Hua .
OPTICS EXPRESS, 2006, 14 (16) :7420-7435
[5]   TIME-RESOLVED REFLECTANCE - A SYSTEMATIC STUDY FOR APPLICATION TO THE OPTICAL CHARACTERIZATION OF TISSUES [J].
CUBEDDU, R ;
MUSOLINO, M ;
PIFFERI, A ;
TARONI, P ;
VALENTINI, G .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1994, 30 (10) :2421-2430
[6]   Liquid phantom for investigating light propagation through layered diffusive media [J].
Del Bianco, S ;
Martelli, F ;
Cignini, F ;
Zaccanti, G ;
Pifferi, A ;
Torricelli, A ;
Bassi, A ;
Taroni, P ;
Cubeddu, R .
OPTICS EXPRESS, 2004, 12 (10) :2102-2111
[7]   Intralipid: towards a diffusive reference standard for optical tissue phantoms [J].
Di Ninni, Paola ;
Martelli, Fabrizio ;
Zaccanti, Giovanni .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (02) :N21-N28
[8]   The use of India ink in tissue-simulating phantoms [J].
Di Ninni, Paola ;
Martelli, Fabrizio ;
Zaccanti, Giovanni .
OPTICS EXPRESS, 2010, 18 (26) :26854-26865
[9]  
Drolen B. L., 1987, Journal of Thermophysics and Heat Transfer, V1, P63, DOI 10.2514/3.8
[10]   SEMI-INFINITE-GEOMETRY BOUNDARY-PROBLEM FOR LIGHT MIGRATION IN HIGHLY SCATTERING MEDIA - A FREQUENCY-DOMAIN STUDY IN THE DIFFUSION-APPROXIMATION [J].
FANTINI, S ;
FRANCESCHINI, MA ;
GRATTON, E .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1994, 11 (10) :2128-2138