DSP Implementation for Measuring the Loop Gain Frequency Response of Digitally Controlled Power Converters

被引:27
作者
Castello, Jaime [1 ]
Espi, Jose M. [1 ]
机构
[1] Univ Valencia, Dept Elect Engn, E-46100 Valencia, Spain
关键词
Dead-beat control; digital signal processor (DSP); loop gain measurement; power system control; robust predictive current control (RPCC); universal serial bus (USB); PREDICTIVE CURRENT CONTROL; CONTROL SCHEME; INVERTERS;
D O I
10.1109/TPEL.2012.2190102
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a method for measuring the loop gain frequency response of digitally controlled power converters, without the need of any expensive measurement equipment such as frequency response analyzers (FRA). The method is based on the traditional perturbation and measurement scheme. The perturbation is internally synthesized by the DSP and applied as pulse-width modulation to the converter. The loop input and output data are sent to a PC via universal serial bus, which performs online the DFT of sent data. The perturbation amplitude is varied with frequency to improve signal-to-noise ratio of measurements. The number of cycles used to perform discrete Fourier transform calculations is also varied to reduce the error induced by some rounding factors at high frequencies. The proposed method offers accuracy, ease of implementation, and low computational cost.
引用
收藏
页码:4113 / 4121
页数:9
相关论文
共 25 条
[1]   Improved Online Identification of a DC-DC Converter and Its Control Loop Gain Using Cross-Correlation Methods [J].
Barkley, Adam ;
Santi, Enrico .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (08) :2021-2031
[2]   An improved robust predictive current regulation algorithm [J].
Bode, GH ;
Loh, PC ;
Newman, MJ ;
Holmes, DG .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (06) :1720-1733
[3]   A Robust Predictive Current Control for Three-Phase Grid-Connected Inverters [J].
Castello Moreno, Jaime ;
Espi Huerta, Jose M. ;
Garcia Gil, Rafael ;
Alejandro Gonzalez, Sergio .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (06) :1993-2004
[4]  
Erickson R. W., 2004, FUNDAMENTALS POWER E, VSecond
[5]   A Synchronous Reference Frame Robust Predictive Current Control for Three-Phase Grid-Connected Inverters [J].
Espi Huerta, Jose M. ;
Castello-Moreno, Jaime ;
Roberto Fischer, Jonatan ;
Garcia-Gil, Rafael .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (03) :954-962
[6]   An Adaptive Robust Predictive Current Control for Three-Phase Grid-Connected Inverters [J].
Espi, Jose M. ;
Castello, Jaime ;
Garcia-Gil, Rafael ;
Garcera, Gabriel ;
Figueres, Emilio .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (08) :3537-3546
[7]   Sensitivity Study of the Dynamics of Three-Phase Photovoltaic Inverters With an LCL Grid Filter [J].
Figueres, Emilio ;
Garcera, Gabriel ;
Sandia, Jesus ;
Gonzalez-Espin, Francisco ;
Calvo Rubio, Jesus .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (03) :706-717
[8]   Measurement of the Loop Gain Frequency Response of Digitally Controlled Power Converters [J].
Gonzalez-Espin, Fran ;
Figueres, Emilio ;
Garcera, Gabriel ;
Gonzalez-Medina, Raul ;
Pascual, Marcos .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (08) :2785-2796
[9]  
HOLME PR, 1994, INTERNATIONAL CONFERENCE ON CONTROL 94, VOLS 1 AND 2, P1235
[10]  
Holmes DG, 1996, IEEE IND APPLIC SOC, P906, DOI 10.1109/IAS.1996.560191