Diagnostic test accuracy of ultrasound for synovitis in rheumatoid arthritis: systematic review and meta-analysis

被引:60
|
作者
Takase-Minegishi, Kaoru [1 ]
Horita, Nobuyuki [2 ]
Kobayashi, Kouji [1 ]
Yoshimi, Ryusuke [3 ]
Kirino, Yohei [3 ]
Ohno, Shigeru [1 ]
Kaneko, Takeshi [2 ]
Nakajima, Hideaki [3 ]
Wakefield, Richard J. [4 ]
Emery, Paul [4 ]
机构
[1] Yokohama City Univ, Med Ctr, Ctr Rheumat Dis, Yokohama, Kanagawa, Japan
[2] Yokohama City Univ, Grad Sch Med, Dept Pulmonol, Yokohama, Kanagawa, Japan
[3] Yokohama City Univ, Grad Sch Med, Dept Stem Cell & Immune Regulat, Yokohama, Kanagawa, Japan
[4] Univ Leeds, Leeds Teaching Hosp NHS Trust, NIHR Leeds Musculoskeletal Biomed Res Unit, Leeds Inst Rheumat & Musculoskeletal Med, Leeds, W Yorkshire, England
基金
日本学术振兴会;
关键词
rheumatoid arthritis; ultrasound; magnetic resonance imaging; POWER DOPPLER ULTRASONOGRAPHY; DYNAMIC MAGNETIC-RESONANCE; CLINICAL REMISSION; METACARPOPHALANGEAL JOINTS; KNEE SYNOVITIS; COHORTS; CONTRAST; CLASSIFICATION; INFLAMMATION; PREDICTION;
D O I
10.1093/rheumatology/kex036
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. To evaluate diagnostic test accuracy of US compared with MRI for the detection of synovitis in RA patients. Methods. A systematic literature search was performed in the PubMed, EMBASE, Cochrane Library and Web of Science Core Collection databases. Studies evaluating the diagnostic test accuracy of US for synovitis detected by MRI as the reference standard for wrist, MCP, PIP and knee joints were included. To assess the overall accuracy, we calculated the diagnostic odds ratio using a DerSimonian-Laird random effects model and the area under the curve (AUC) for the hierarchical summary receiver operating characteristics using Holling's proportional hazards models. The summary estimate of the sensitivity and specificity were obtained using the bivariate model. Results. Fourteen of 601 identified articles were included in the review. The diagnostic odds ratio was 11.6 (95% CI 5.6, 24; I-2 = 0%), 28 (95% CI 12, 66; I-2 = 11%), 23 (95% CI 6.5, 84; I-2 = 19%) and 5.3 (95% CI 0.60, 48; I-2 = 0%) and the AUC was 0.81, 0.91, 0.91 and 0.61 for wrist, MCP, PIP and knee joints, respectively. The summary estimates of sensitivity and specificity were 0.73 (95% CI 0.51, 0.87)/0.78 (95% CI 0.46, 0.94), 0.64 (95% CI 0.43, 0.81)/0.93 (95% CI 0.88, 0.97), 0.71 (95% CI 0.33, 0.93)/0.94 (95% CI 0.89, 0.97) and 0.91 (95% CI 0.56, 0.99)/0.60 (95% CI 0.20, 0.90) for wrist, MCP, PIP and knee joints, respectively. Conclusion. US is a valid and reproducible technique for detecting synovitis in the wrist and finger joints. It may be considered for routine use as part of the standard diagnostic tools in RA.
引用
收藏
页码:49 / 58
页数:10
相关论文
共 50 条
  • [31] Diagnostic Accuracy of Abdominal Ultrasound for Diagnosis of Acute Appendicitis: Systematic Review and Meta-analysis
    Vanja Giljaca
    Tin Nadarevic
    Goran Poropat
    Vesna Stefanac Nadarevic
    Davor Stimac
    World Journal of Surgery, 2017, 41 : 693 - 700
  • [32] Diagnostic accuracy of ultrasound for rotator cuff tears in adults: A systematic review and meta-analysis
    Smith, T. O.
    Back, T.
    Toms, A. P.
    Hing, C. B.
    CLINICAL RADIOLOGY, 2011, 66 (11) : 1036 - 1048
  • [33] Diagnostic accuracy of ultrasound in diagnosing acute appendicitis in pregnancy: a systematic review and meta-analysis
    Maryam Nakhaie Moghadam
    Morteza Salarzaei
    Zahra Shahraki
    Emergency Radiology, 2022, 29 : 437 - 448
  • [34] Diagnostic Accuracy of Abdominal Ultrasound for Diagnosis of Acute Appendicitis: Systematic Review and Meta-analysis
    Giljaca, Vanja
    Nadarevic, Tin
    Poropat, Goran
    Nadarevic, Vesna Stefanac
    Stimac, Davor
    WORLD JOURNAL OF SURGERY, 2017, 41 (03) : 693 - 700
  • [35] DIAGNOSTIC ACCURACY OF ABDOMINAL ULTRASOUND FOR DIAGNOSIS OF ACUTE APPENDICITIS: SYSTEMATIC REVIEW AND META-ANALYSIS
    Giljaca, V.
    Nadarevic, T.
    Poropat, G.
    Nadarevic, V. Stefanac
    Stimac, D.
    GUT, 2017, 66 : A140 - A140
  • [36] Diagnostic accuracy of diaphragm ultrasound to predict weaning outcome: A systematic review and meta-analysis
    Le Neindre, Aymeric
    Philippart, Francois
    Luperto, Marta
    Wormser, Johan
    Morel-Sapene, Johanna
    Aho, Serge L.
    Mongodi, Silvia
    Mojoli, Francesco
    Bouhemad, Belaid
    INTERNATIONAL JOURNAL OF NURSING STUDIES, 2021, 117
  • [37] Diagnostic accuracy of multiparametric ultrasound in the diagnosis of prostate cancer: systematic review and meta-analysis
    Yun Tang
    Xingsheng Li
    Qing Jiang
    Lingyun Zhai
    Insights into Imaging, 14
  • [38] Diagnostic accuracy of lung ultrasound to predict weaning outcome: a systematic review and meta-analysis
    Zhang, Zhiyang
    Guo, Li
    Wang, Huawei
    Zhang, Ze
    Shen, Limin
    Zhao, Heling
    FRONTIERS IN MEDICINE, 2024, 11
  • [39] Diagnostic accuracy of ultrasound signs for detecting adnexal torsion: systematic review and meta-analysis
    Garde, I.
    Paredes, C.
    Ventura, L.
    Pascual, M. A.
    Ajossa, S.
    Guerriero, S.
    Vara, J.
    Linares, M.
    Alcazar, J. L.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2023, 61 (03) : 310 - 324
  • [40] Diagnostic accuracy of ultrasound in the diagnosis of Placenta accreta spectrum: systematic review and meta-analysis
    Maged, Ahmed M.
    El-Mazny, Akmal
    Kamal, Nada
    Mahmoud, Safaa I.
    Fouad, Mona
    El-Nassery, Noura
    Kotb, Amal
    Ragab, Wael S.
    Ogila, Asmaa I.
    Metwally, Ahmed A.
    Lasheen, Yossra
    Fahmy, Radwa M.
    Katta, Maha
    Shaeer, Eman K.
    Salah, Noha