Accuracy of arterial pressure waveform analysis for cardiac output measurement in comparison with thermodilution methods in patients undergoing living donor liver transplantation

被引:16
作者
Akiyoshi, Kozaburo [1 ]
Kandabashi, Tadashi [1 ]
Kaji, Junko [1 ]
Yamaura, Ken [1 ]
Yoshimura, Hayashi [1 ]
Irita, Kazuo [1 ]
Hoka, Sumio [1 ]
机构
[1] Kyushu Univ Hosp, Dept Anesthesiol & Crit Care Med, Higashi Ku, Fukuoka 8128582, Japan
关键词
Cardiac output; Arterial pressure waveform cardiac output; Thermodilution; Systemic vascular resistance; HYPERDYNAMIC CIRCULATION; VALIDATION; CIRRHOSIS;
D O I
10.1007/s00540-010-1087-y
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The aim of this study was to assess the accuracy of the first and third versions of arterial pressure waveform cardiac output (APCO(v.1.0) and APCO(v.3.0)) measurements in comparison with thermodilution methods in patients undergoing living donor liver transplantation. Twenty patients were anesthetized and mechanically ventilated. A radial arterial line was connected to a dedicated transducer for the APCO evaluation (FloTrac (TM)). A pulmonary artery catheter was placed and connected to a computer system (Vigilance (TM)) to measure intermittent thermodilution cardiac output (COTD) and continuous cardiac output (CCO). A total of 138 measurements were analyzed. Bland-Altman analysis showed that the mean biases for COTD-APCO(v.3.0), COTD-APCO(v.1.0), and COTD-CCO were 0.89, 1.73, and -0.79 L/min, and the adjusted percentage errors were 37.5, 30.3, and 43%, respectively. While the variance for COTD-APCO(v3.0) was greater, the accuracy (bias) improved by 0.8 L/min as compared with COTD-APCO(v1.0). The difference COTD-APCO(v.3.0) became apparent when systemic vascular resistance was lower than 1000 dyne x s/cm(5), especially below 700 dyne x s/cm(5). These data suggest that the accuracy of APCO(v.3.0) has improved compared to APCO(v.1.0) due to the updated algorithm, but additional improvements should be evaluated, especially in patients undergoing living donor liver transplantation with low systemic vascular resistance.
引用
收藏
页码:178 / 183
页数:6
相关论文
共 19 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   The hyperdynamic circulation in cirrhosis: an overview [J].
Blendis, L ;
Wong, F .
PHARMACOLOGY & THERAPEUTICS, 2001, 89 (03) :221-231
[3]   Clinical evaluation of the FloTrac/Nigileo™ system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery [J].
Button, D. ;
Weibel, L. ;
Reuthebuch, O. ;
Genoni, M. ;
Zollinger, A. ;
Hofer, C. K. .
BRITISH JOURNAL OF ANAESTHESIA, 2007, 99 (03) :329-336
[4]  
COSTA MG, 2006, ANESTHESIOLOGY, V105, pA463
[5]   A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques [J].
Critchley, LAH ;
Critchley, JAJH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) :85-91
[6]  
De Backer D, 2009, INTENS CARE MED, V35, P13
[7]   Validation of a new arterial pulse contour-based cardiac output device [J].
de Waal, Eric E. C. ;
Kalkman, Cor J. ;
Rex, Steffen ;
Buhre, Wolfgang F. .
CRITICAL CARE MEDICINE, 2007, 35 (08) :1904-1909
[8]  
Dincer D, 2005, HEPATO-GASTROENTEROL, V52, P1521
[9]   Stability of cirrhotic systemic hemodynamics ensures sufficient splanchnic blood flow after living-donor liver transplantation in adult recipients with liver cirrhosis [J].
Hori, Tomohide ;
Yagi, Shintaro ;
Iida, Taku ;
Taniguchi, Kentaro ;
Yamagiwa, Kentaro ;
Yamamoto, Chicluru ;
Hasegawa, Takashi ;
Yamakado, Koichiro ;
Kato, Takuma ;
Saito, Kanako ;
Wang, Linan ;
Torii, Mie ;
Hori, Yukinobu ;
Takeda, Kan ;
Maruyama, Kazuo ;
Uemoto, Shinji .
WORLD JOURNAL OF GASTROENTEROLOGY, 2007, 13 (44) :5918-5925
[10]   Edwards FloTrac™ sensor and Vigileo™ monitor:: easy, accurate, reliable cardiac output assessment using the arterial pulse wave [J].
Manecke, Gerard R. .