An efficient algorithm for measurement of retinal vessel diameter from fundus images based on directional filtering

被引:0
作者
Wang, Xuchu [1 ]
Niu, Yanmin [2 ]
机构
[1] Chongqing Univ, Minist Educ, Key Lab Optoelect Technol & Syst, Coll Optoelect Engn, Chongqing 400044, Peoples R China
[2] Chongqing Normal Univ, Coll Comp & Informat Sci, Chongqing 400050, Peoples R China
来源
PIAGENG 2010: PHOTONICS AND IMAGING FOR AGRICULTURAL ENGINEERING | 2010年 / 7752卷
关键词
Retinal image analysis; retinal vessel; diameter measurement; Gabor wavelet; orientation estimation; QUANTIFICATION;
D O I
10.1117/12.888298
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Automatic measurement of vessels from fundus images is a crucial step for assessing vessel anomalies in ophthalmological community, where the change in retinal vessel diameters is believed to be indicative of the risk level of diabetic retinopathy. In this paper, a new retinal vessel diameter measurement method by combining vessel orientation estimation and filter response is proposed. Its interesting characteristics include: (1) different from the methods that only fit the vessel profiles, the proposed method extracts more stable and accurate vessel diameter by casting this problem as a maximal response problem of a variation of Gabor filter; (2) the proposed method can directly and efficiently estimate the vessel's orientation, which is usually captured by time-consuming multi-orientation fitting techniques in many existing methods. Experimental results shows that the proposed method both retains the computational simplicity and achieves stable and accurate estimation results.
引用
收藏
页数:4
相关论文
共 10 条
[1]   An Active Contour Model for Segmenting and Measuring Retinal Vessels [J].
Al-Diri, Bashir ;
Hunter, Andrew ;
Steel, David .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (09) :1488-1497
[2]  
Brinchmann-Hansen O., 1986, ACTA OPHTHALMOL, V64, P33, DOI [DOI 10.1111/J.1755-3768.1986.TB00701.X, 10.1111/j.1755-3768.1986.tb00701.x]
[3]   Quantification and characterisation of arteries in retinal images [J].
Gao, XHW ;
Bharath, A ;
Stanton, A ;
Hughes, A ;
Chapman, N ;
Thom, S .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2000, 63 (02) :133-146
[4]   AUTOMATED GRADING OF VENOUS BEADING [J].
GREGSON, PH ;
SHEN, Z ;
SCOTT, RC ;
KOZOUSEK, V .
COMPUTERS AND BIOMEDICAL RESEARCH, 1995, 28 (04) :291-304
[5]   Measurement of retinal vessel widths from fundus images based on 2-D modeling [J].
Lowell, J ;
Hunter, A ;
Steel, D ;
Basu, A ;
Ryder, R ;
Kennedy, RL .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (10) :1196-1204
[6]   Quantitative measurement of changes in retinal vessel diameter in ocular fundus images [J].
Pedersen, L ;
Grunkin, M ;
Ersboll, B ;
Madsen, K ;
Larsen, M ;
Christoffersen, N ;
Skands, U .
PATTERN RECOGNITION LETTERS, 2000, 21 (13-14) :1215-1223
[7]  
Wang XC, 2005, LECT NOTES COMPUT SC, V3781, P111, DOI 10.1007/11569947_14
[8]   Fingerprint matching using OrientationCodes and PolyLines [J].
Wang, Xuchu ;
Li, Jianwei ;
Niu, Yanmin .
PATTERN RECOGNITION, 2007, 40 (11) :3164-3177
[9]   Definition and extraction of stable points from fingerprint images [J].
Wang, Xuchu ;
Li, Jianwei ;
Niu, Yanmin .
PATTERN RECOGNITION, 2007, 40 (06) :1804-1815
[10]  
ZHOU LA, 1994, IEEE T MED IMAGING, V13, P619, DOI 10.1109/42.363106