Hemodynamic effects of epinephrine in rats: evaluation by impedance cardiography

被引:4
作者
Turkseven, C. H. [1 ]
Pekoglu, E. [1 ]
Buyukakilli, B. [1 ]
机构
[1] Mersin Univ, Dept Biophys, Fac Med, TR-33343 Mersin, Turkey
来源
BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY | 2017年 / 118卷 / 10期
关键词
impedance cardiography; epinephrine; bioimpedance; hemodynamic; CARDIAC-OUTPUT; STROKE VOLUME; HEART; BIOIMPEDANCE; CHANNELS;
D O I
10.4149/BLL_2017_118
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND AND OBJECTIVES: This study was aimed to examine how inotropic effects of intravenously injected epinephrine change thoracic impedance measurements and to reveal the possible effects of this change on other hemodynamic parameters by using the technique of impedance cardiography. METHODS: 10 male Wistar Albino rats were divided into two equal groups: control and epinephrine. 0.2 mg/kg of epinephrine was administered to the rats in the epinephrine group via the tail vein. All hemodynamic parameters obtained by impedance cardiography [the base impedance (Z(0))(1) the maximum rate of change in impedance (dZ(max)/dt), the left ventricular ejection time (LVET), stroke volume (SV), cardiac output (CO), contractility index (IC), thoracic fluid content (TFC), heart rate (HR)] were recorded using the EBI 100C, DA 100 and ECG modules in the BIOPAC MP100 system. RESULTS: CO (p <= 0.05), HR (p <= 0.001), dZ(max)/dt (p <= 0.05) and IC (p <= 0.05) increased statistically significantly in the epinephrine group compared to the control group. However, LVET (p <= 0.001) decreased statistically significantly in the epinephrine group compared to the control group. CONCLUSION: Tachycardia was detected in the epinephrine group. There was an inverse correlation between LVET and dZmax/dt and IC. This is based on the fact that epinephrine increases inotropic effect
引用
收藏
页码:613 / 617
页数:5
相关论文
共 31 条
[1]   Narrative review: Cardiopulmonary resuscitation and emergency cardiovascular care: Review of the current guidelines [J].
Ali, Bakhtiar ;
Zafari, A. Maziar .
ANNALS OF INTERNAL MEDICINE, 2007, 147 (03) :171-179
[2]  
[Anonymous], 2005, Circulation, V112, pIV1, DOI [DOI 10.1161/CIRCULATIONAHA.105.166550, 10.1161/CIRCULATIONAHA.105.166550]
[3]   Device-based impedance measurement is a useful and accurate tool for direct assessment of intrathoracic fluid accumulation in heart failure [J].
Becher, Jan ;
Kaufmann, Susann G. ;
Paule, Stefan ;
Fahn, Bernhard ;
Skerl, Olaf ;
Bauer, Wolfgang R. ;
Ertl, Georg ;
Maier, Sebastian K. G. .
EUROPACE, 2010, 12 (05) :731-740
[4]   A NEW STROKE VOLUME EQUATION FOR THORACIC ELECTRICAL BIOIMPEDANCE - THEORY AND RATIONALE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :904-909
[5]   The L-type calcium channel in the heart: the beat goes on [J].
Bodi, I ;
Mikala, G ;
Koch, SE ;
Akhter, SA ;
Schwartz, A .
JOURNAL OF CLINICAL INVESTIGATION, 2005, 115 (12) :3306-3317
[6]   Determination of the effects of pulmonary arterial hypertension and therapy on the cardiovascular system of rats by impedance cardiography [J].
Buyukakilli, Belgin ;
Gurgul, Serkan ;
Citirik, Derya ;
Hallioglu, Olgu ;
Ozeren, Murat ;
Tasdelen, Bahar .
CROATIAN MEDICAL JOURNAL, 2014, 55 (05) :498-506
[7]   What is the optimal dose of epinephrine during cardiopulmonary resuscitation in a rat model? [J].
Chen, Meng-Hua ;
Lu, Jun-Yu ;
Xie, Lu ;
Zheng, Jun-Hui ;
Song, Feng-Qing .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2010, 28 (03) :284-290
[8]  
Cummins RO, 2003, ADV CARDIOVASCULAR L, P239
[9]   Impedance cardiography: Recent advancements [J].
Cybulski, Gerard ;
Strasz, Anna ;
Niewiadomski, Wiktor ;
Gasiorowska, Anna .
CARDIOLOGY JOURNAL, 2012, 19 (05) :550-556
[10]  
DePasquale MJ, 1996, DRUG DEVELOP RES, V38, P105, DOI 10.1002/(SICI)1098-2299(199606)38:2<105::AID-DDR4>3.0.CO