Characterization of temporal coherence of hard X-ray free-electron laser pulses with single-shot interferograms

被引:28
|
作者
Osaka, Taito [1 ,2 ]
Hirano, Takashi [2 ]
Morioka, Yuki [2 ]
Sano, Yasuhisa [2 ]
Inubushi, Yuichi [1 ,3 ]
Togashi, Tadashi [1 ,3 ]
Inoue, Ichiro [1 ]
Tono, Kensuke [1 ,3 ]
Robert, Aymeric [4 ]
Yamauchi, Kazuto [2 ]
Hastings, Jerome B. [4 ]
Yabashi, Makina [1 ,3 ]
机构
[1] RIKEN, SPring Ctr 8, 1-1-1 Kouto, Sayo, Hyogo 6795148, Japan
[2] Osaka Univ, Grad Sch Engn, Dept Precis Sci & Technol, 2-1 Yamada Oka, Suita, Osaka 5650871, Japan
[3] Japan Synchrotron Radiat Res Inst JASRI, 1-1-1 Kouto, Sayo, Hyogo 6795198, Japan
[4] SLAC Natl Accelerator Lab, Linac Coherent Light Source, 2575 Sand Hill Rd,MS 102, Menlo Pk, CA 94025 USA
来源
IUCRJ | 2017年 / 4卷
关键词
X-ray interferometry; split-and-delay optical system; X-ray free-electron lasers; temporal coherence; DELAY-LINE; INTERFEROMETER; SPECTROSCOPY; RESOLUTION; SPECKLE; UNIT;
D O I
10.1107/S2052252517014014
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Temporal coherence is one of the most fundamental characteristics of light, connecting to spectral information through the Fourier transform relationship between time and frequency. Interferometers with a variable path-length difference (PLD) between the two branches have widely been employed to characterize temporal coherence properties for broad spectral regimes. Hard X-ray interferometers reported previously, however, have strict limitations in their operational photon energies, due to the specific optical layouts utilized to satisfy the stringent requirement for extreme stability of the PLD at subangstrom scales. The work presented here characterizes the temporal coherence of hard X-ray free-electron laser (XFEL) pulses by capturing single-shot interferograms. Since the stability requirement is drastically relieved with this approach, it was possible to build a versatile hard X-ray interferometer composed of six separate optical elements to cover a wide photon energy range from 6.5 to 11.5 keV while providing a large variable delay time of up to 47 ps at 10 keV. A high visibility of up to 0.55 was observed at a photon energy of 10 keV. The visibility measurement as a function of time delay reveals a mean coherence time of 5.9 +/- 0.7 fs, which agrees with that expected from the single-shot spectral information. This is the first result of characterizing the temporal coherence of XFEL pulses in the hard X-ray regime and is an important milestone towards ultra-high energy resolutions at micro-electronvolt levels in time-domain X-ray spectroscopy, which will open up new opportunities for revealing dynamic properties in diverse systems on timescales from femtoseconds to nanoseconds, associated with fluctuations from anngstrom to nanometre spatial scales.
引用
收藏
页码:728 / 733
页数:6
相关论文
共 50 条
  • [31] TEACHING THE PRINCIPLES AND APPLICATIONS OF X-RAY FREE-ELECTRON LASER RADIATION
    Tschentscher, Th.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2002, 58 : C199 - C199
  • [32] Resolution of a bent-crystal spectrometer for X-ray free-electron laser pulses: diamond versus silicon
    Kaganer, Vladimir M.
    Petrov, Ilia
    Samoylova, Liubov
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2021, 77 : 268 - 276
  • [33] Amorphous to crystalline phase transition in carbon induced by intense femtosecond x-ray free-electron laser pulses
    Gaudin, J.
    Peyrusse, O.
    Chalupsky, J.
    Toufarova, M.
    Vysin, L.
    Hajkova, V.
    Sobierajski, R.
    Burian, T.
    Dastjani-Farahani, Sh.
    Graf, A.
    Amati, M.
    Gregoratti, L.
    Hau-Riege, S. P.
    Hoffmann, G.
    Juha, L.
    Krzywinski, J.
    London, R. A.
    Moeller, S.
    Sinn, H.
    Schorb, S.
    Stoermer, M.
    Tschentscher, Th.
    Vorlicek, V.
    Vu, H.
    Bozek, J.
    Bostedt, C.
    PHYSICAL REVIEW B, 2012, 86 (02)
  • [34] Application of an ePix100 detector for coherent scattering using a hard X-ray free-electron laser
    Sikorski, Marcin
    Feng, Yiping
    Song, Sanghoon
    Zhu, Diling
    Carini, Gabriella
    Herrmann, Sven
    Nishimura, Kurtis
    Hart, Philip
    Robert, Aymeric
    JOURNAL OF SYNCHROTRON RADIATION, 2016, 23 : 1171 - 1179
  • [35] Development of a hard X-ray delay line for X-ray photon correlation spectroscopy and jitter-free pump-probe experiments at X-ray free-electron laser sources
    Roseker, Wojciech
    Franz, Hermann
    Schulte-Schrepping, Horst
    Ehnes, Anita
    Leupold, Olaf
    Zontone, Federico
    Lee, Sooheyong
    Robert, Aymeric
    Gruebel, Gerhard
    JOURNAL OF SYNCHROTRON RADIATION, 2011, 18 : 481 - 491
  • [36] Protein structure determination by single-wavelength anomalous diffraction phasing of X-ray free-electron laser data
    Nass, Karol
    Meinhart, Anton
    Barends, Thomas R. M.
    Foucar, Lutz
    Gorel, Alexander
    Aquila, Andrew
    Botha, Sabine
    Doak, R. Bruce
    Koglin, Jason
    Liang, Mengning
    Shoeman, Robert L.
    Williams, Garth
    Boutet, Sebastien
    Schlichting, Ilme
    IUCRJ, 2016, 3 : 180 - 191
  • [37] Single-shot soft x-ray laser linewidth measurement using a grating interferometer
    Wang, Y.
    Yin, L.
    Wang, S.
    Marconi, M. C.
    Dunn, J.
    Gullikson, E.
    Rocca, J. J.
    OPTICS LETTERS, 2013, 38 (23) : 5004 - 5007
  • [38] Single-pulse phase-contrast imaging at free-electron lasers in the hard X-ray regime
    Hagemann, Johannes
    Vassholz, Malte
    Hoeppe, Hannes
    Osterhoff, Markus
    Rossello, Juan M.
    Mettin, Robert
    Seiboth, Frank
    Schropp, Andreas
    Moeller, Johannes
    Hallmann, Joerg
    Kim, Chan
    Scholz, Markus
    Boesenberg, Ulrike
    Schaffer, Robert
    Zozulya, Alexey
    Lu, Wei
    Shayduk, Roman
    Madsen, Anders
    Schroer, Christian G.
    Salditt, Tim
    JOURNAL OF SYNCHROTRON RADIATION, 2021, 28 : 52 - 63
  • [39] Spectrometer for single-shot X-ray emission and photon diagnostics
    Frassetto, F.
    Miotti, P.
    Callegari, C.
    de Simone, M.
    Finetti, P.
    Giangrisostomi, E.
    Grazioli, C.
    Iesari, F.
    Kivimaeki, A.
    Mincigrucci, R.
    Principi, E.
    Stagira, S.
    Di Cicco, A.
    Coreno, M.
    Poletto, L.
    X-RAY FREE-ELECTRON LASERS: BEAM DIAGNOSTICS, BEAMLINE INSTRUMENTATION, AND APPLICATIONS II, 2014, 9210
  • [40] Nanofocusing of hard X-ray free electron laser pulses using diamond based Fresnel zone plates
    David, C.
    Gorelick, S.
    Rutishauser, S.
    Krzywinski, J.
    Vila-Comamala, J.
    Guzenko, V. A.
    Bunk, O.
    Farm, E.
    Ritala, M.
    Cammarata, M.
    Fritz, D. M.
    Barrett, R.
    Samoylova, L.
    Gruenert, J.
    Sinn, H.
    SCIENTIFIC REPORTS, 2011, 1