Ultrasound palpation sensor for tissue thickness and elasticity measurement - Assessment of transverse carpal ligament

被引:15
作者
Zheng, Y. P. [1 ]
Li, Z. M.
Choi, A. P. C.
Lu, M. H.
Chen, X.
Huang, Q. H.
机构
[1] Hong Kong Polytech Univ, Dept Hlth Technol & Informat, Kowloon, Hong Kong, Peoples R China
[2] Univ Pittsburgh, Dept Orthopaed, Hand Res Lab, Pittsburgh, PA 15260 USA
关键词
palpation; ultrasound; ultrasound palpation; tissue elasticity; soft tissue; carpal tunnel syndrome;
D O I
10.1016/j.ultras.2006.06.018
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Palpation is a traditional diagnostic procedure for health care professionals to use their fingers to touch and feel the body soft tissues. It is a common clinical approach, though it is rather subjective and qualitative and the palpation results may vary among different people. Tissue ultrasound palpation sensor ( TUPS) provides a feasible solution that makes the palpation of soft tissues not subjective feeling any more. It is comprised of an ultrasound transducer together with a load cell to form the finger- sized probe. The probe is used to push against the soft tissue surface to measure the thickness and elasticity of the soft tissues. TUPS has been successfully applied to the assessment of various human tissues. Recently, we have improved TUPS, which can now be linked to personal computer ( PC) via universal serial bus ( USB) and provide a better user- interface. The information of ultrasound signal and indentation force is displayed on PC in real time during measurement. In this paper, we introduce the recent application of TUPS for the assessment of the transverse carpal ligament. The tissues at the carpal tunnel regions of five normal male subjects were tested using TUPS. The results showed that the average thickness of the tissues covering the carpal tunnel ligament and the tunnel region was 7.98 +/- 1.05 mm and 9.59 +/- 1.12 mm, respectively. Under a compression force of 20 N applied by a cylindrical ultrasound indentor with a diameter of 9 mm, the stiffness of the soft tissue layer and the tunnel region was 6.72 +/- 2.10 N/ mm and 15.63 +/- 8.42 N/ mm, respectively. It is expected that TUPS can be a potential tool for non- invasive assessment of carpal tunnel syndrome. (c) 2006 Elsevier B. V. All rights reserved.
引用
收藏
页码:E313 / E317
页数:5
相关论文
共 12 条
[1]   Intracarpal steroid injection is safe and effective for short-term management of carpal tunnel syndrome [J].
Armstrong, T ;
Devor, W ;
Borschel, L ;
Contreras, R .
MUSCLE & NERVE, 2004, 29 (01) :82-88
[2]   COMPILATION OF EMPIRICAL ULTRASONIC PROPERTIES OF MAMMALIAN-TISSUES .2. [J].
GOSS, SA ;
JOHNSTON, RL ;
DUNN, F .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1980, 68 (01) :93-108
[3]   Quasi-linear viscoelastic properties of fibrotic neck tissues obtained from ultrasound indentation tests in vivo [J].
Huang, YP ;
Zheng, YP ;
Leung, SF .
CLINICAL BIOMECHANICS, 2005, 20 (02) :145-154
[4]  
JOHN V, 1983, AM J NEURORADIOL, V4, P770
[5]   Application of tissue ultrasound palpation system (TUPS) in objective scar evaluation [J].
Lau, JCM ;
Li-Tsang, CWP ;
Zheng, YP .
BURNS, 2005, 31 (04) :445-452
[6]  
Moore KL., 1999, CLIN ORIENTED ANATOM, V4th
[7]   Transverse carpal ligament: Its effect on flexor tendon excursion, morphologic changes of the carpal canal, and on pinch and grip strengths after open carpal tunnel release [J].
Netscher, D ;
Mosharrafa, A ;
Lee, M ;
Polsen, C ;
Choi, H ;
Steadman, AK ;
Thornby, J .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 100 (03) :636-642
[8]  
Sucher Benjamin M., 1998, Journal of the American Osteopathic Association, V98, P679
[9]  
Zheng Y, 1999, IEEE Trans Rehabil Eng, V7, P257, DOI 10.1109/86.788463
[10]   Biomechanical assessment of plantar foot tissue in diabetic patients using an ultrasound indentation system [J].
Zheng, YP ;
Choi, YKC ;
Wong, K ;
Chan, S ;
Mak, AFT .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (03) :451-456