Using adiabatic inversion pulses for long-T2 suppression in ultrashort echo time (UTE) imaging

被引:89
作者
Larson, Peder E. Z. [1 ]
Conolly, Steven M. [1 ]
Pauly, John M. [1 ]
Nishimura, Dwight G. [1 ]
机构
[1] Stanford Univ, Dept Elect Engn, Magnet Resonance Syst Res Lab, Stanford, CA 94305 USA
关键词
ultrashort echo time (UTE) imaging; long-T-2; suppression; short-T-2; imaging; adiabatic pulses;
D O I
10.1002/mrm.21341
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Ultrashort echo time (UTE) imaging is a technique that can visualize tissues with sub-millisecond T-2 values that have little or no signal in conventional MRI techniques. The short-T-2 tissues, which include tendons, menisci, calcifications, and cortical bone, are often obscured by long-T-2 tissues. This paper introduces a new method of long-T-2 component suppression based on adiabatic inversion pulses that significantly improves the contrast of short-T-2 tissues. Narrow bandwidth inversion pulses are used to selectively invert only long-T-2 components. These components are then suppressed by combining images prepared with and without inversion pulses. Fat suppression can be incorporated by combining images with the pulses applied on the fat and water resonances. Scaling factors must be used in the combination to compensate for relaxation during the preparation pulses. The suppression is insensitive to RF inhomogeneities because it uses adiabatic inversion pulses. Simulations and phantom experiments demonstrate the adiabatic pulse contrast and how the scaling factors are chosen. In vivo 2D UTE images in the ankle and lower leg show excellent, robust long-T-2 suppression for visualization of cortical boneandtendons.
引用
收藏
页码:952 / 961
页数:10
相关论文
共 40 条
[1]   MULTI-EXPONENTIAL WATER PROTON SPIN-LATTICE RELAXATION IN BIOLOGICAL TISSUES AND ITS IMPLICATIONS FOR QUANTITATIVE NMR IMAGING [J].
BAKKER, CJG ;
VRIEND, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (05) :509-518
[2]   Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory [J].
Barger, AV ;
Block, WF ;
Toropov, Y ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) :297-305
[3]   Rapid gridding reconstruction with a minimal oversampling ratio [J].
Beatty, PJ ;
Nishimura, DG ;
Pauly, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (06) :799-808
[4]   LUNG PARENCHYMA - PROJECTION RECONSTRUCTION MR-IMAGING [J].
BERGIN, CJ ;
PAULY, JM ;
MACOVSKI, A .
RADIOLOGY, 1991, 179 (03) :777-781
[5]   MR IMAGING OF LUNG PARENCHYMA - A SOLUTION TO SUSCEPTIBILITY [J].
BERGIN, CJ ;
NOLL, DC ;
PAULY, JM ;
GLOVER, GH ;
MACOVSKI, A .
RADIOLOGY, 1992, 183 (03) :673-676
[6]  
Bernstein MA, 2004, HDB MRI PULSE SEQUEN, P616
[7]  
Brittain J., 2004, P 12 ANN M ISMRM KYO, P629
[8]   EVALUATION OF PROTON DENSITY BY MAGNETIC-RESONANCE-IMAGING - PHANTOM EXPERIMENTS AND ANALYSIS OF MULTIPLE COMPONENT PROTON TRANSVERSE RELAXATION [J].
BRIX, G ;
SCHAD, LR ;
LORENZ, WJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (01) :53-66
[9]   Magnetic resonance imaging of the liver with ultrashort TE (UTE) pulse sequences [J].
Chappell, KE ;
Patel, N ;
Gatehouse, PD ;
Main, J ;
Puri, BK ;
Taylor-Robinson, SD ;
Bydder, GM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (06) :709-713
[10]   The return of the frequency sweep: Designing adiabatic pulses for contemporary NMR [J].