Volumetric parameters-based differentiation of narrow angle from open angle and classification of angle configurations: an SS-OCT study

被引:12
作者
Li, Fei [1 ]
Zhou, Rouxi [1 ]
Gao, Kai [1 ]
Jin, Ling [1 ]
Zhang, Xiulan [1 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangzhou 510060, Guangdong, Peoples R China
基金
国家重点研发计划;
关键词
glaucoma; anterior chamber; swept-source OCT; OPTICAL COHERENCE TOMOGRAPHY; ANTERIOR-CHAMBER PARAMETERS; LASER PERIPHERAL IRIDOTOMY; CLOSURE; GLAUCOMA; ASSOCIATION; IRIS; PENTACAM; CHINESE; EYES;
D O I
10.1136/bjophthalmol-2018-313386
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background To evaluate the diagnostic ability of volumetric parameters to differentiate narrow angle from open angle and distinguish different configurations of narrow angle. Methods The current study was composed of two parts. In the first part, with gonioscopy as reference standard, we tested power of each parameter to differentiate narrow angle from open angle. In the second part, we evaluated the efficacy of different parameters to distinguish angle configurations which were subclassified into type 1 (pupillary block) and type 2 (non-pupillary block and multiple mechanisms) based on ultrasound biomicroscopy (UBM) images. Results In part 1, the training set was composed of 117 narrow-angle eyes and 60 open-angle eyes, and the validation set included 38 narrow-angle eyes and 37 open-angle eyes. Anterior chamber volume (ACV) outperformed all the other parameters with an area under the curve (AUC) of 0.988. The sensitivity and specificity of the cut-off value 98.1 mm(3) in the validation set were 90.0% and 97.1%, respectively. In part 2, training set was composed of 96 eyes of 88 patients with primary angle-closure disease, with 49 diagnosed as type 1 and 47 as type 2 configuration. 32 eyes were used for validation. A model comprised of iris volume (IV), iris thickness (IT) 2000 mu m from the scleral spur and angle open distance (AOD) 750 mu m from the scleral spur was found to have an AUC of 0.793 (95% CI, 0.695 to 0.870). Sensitivity and specificity of the model were 82.6% and 77.8% respectively in the validation set. Conclusions With ACV, we can detect patients with narrow angle from open angle faster and more easily than AOD and anterior chamber depth. Then, for patients with narrow angle, the combination of IV, IT and AOD750 measured by swept-source optical coherence tomography could further classify configurations of angle closure compared with UBM.
引用
收藏
页码:92 / 97
页数:6
相关论文
共 33 条
[1]   Glaucoma anterior chamber morphometry based on optical Scheimpflug images [J].
Alonso, Ruiz Simonato ;
Ambrosio Junior, Renato ;
Paranhos Junior, Augusto ;
Sakaia, Lisandro Massanori ;
Ventura, Marcelo Palis .
ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2010, 73 (06) :497-500
[2]  
[Anonymous], 2017, BRIT J OPHTHALMOL, V101, P73, DOI 10.1136/bjophthalmol-2016-EGSguideline.002
[3]  
[Anonymous], 2017, INT J MOL SCI
[4]   Residual Angle Closure One Year After Laser Peripheral Iridotomy in Primary Angle Closure Suspects [J].
Baskaran, Mani ;
Yang, Elizabeth ;
Trikha, Sameer ;
Kumar, Rajesh S. ;
Wong, Hon Tym ;
He, Mingguang ;
Chew, Paul T. K. ;
Foster, Paul J. ;
Friedman, David ;
Aung, Tin .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2017, 183 :111-117
[5]   Repeatability and comparison of clinical techniques for anterior chamber angle assessment [J].
Campbell, Peter ;
Redmond, Tony ;
Agarwal, Rishi ;
Marshall, Lewis R. ;
Evans, Bruce J. W. .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2015, 35 (02) :170-178
[6]   Anterior Segment Imaging for Angle Closure [J].
Chansangpetch, Sunee ;
Rojanapongpun, Prin ;
Lin, Shan C. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2018, 188 :XVI-XXIX
[7]   Noncontact Screening Methods for the Detection of Narrow Anterior Chamber Angles [J].
Dabasia, Priya L. ;
Edgar, David F. ;
Murdoch, Ian E. ;
Lawrenson, John G. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (06) :3929-3935
[8]   Determinants of Angle Width in Chinese Singaporeans [J].
Foo, Li-Lian ;
Nongpiur, Monisha E. ;
Allen, John C. ;
Perera, Shamira A. ;
Friedman, David S. ;
He, Mingguang ;
Cheng, Ching-Yu ;
Wong, Tien Yin ;
Aung, Tin .
OPHTHALMOLOGY, 2012, 119 (02) :278-282
[9]   Comparison of Scheimpflug imaging and spectral domain anterior segment optical coherence tomography for detection of narrow anterior chamber angles [J].
Grewal, D. S. ;
Brar, G. S. ;
Jain, R. ;
Grewal, S. P. S. .
EYE, 2011, 25 (05) :603-611
[10]   Laser peripheral iridotomy in eyes with narrow drainage angles: Ultrasound biomicroscopy outcomes. The Liwan eye study [J].
He, Mingguang ;
Friedman, David S. ;
Ge, Jian ;
Huang, Wenyong ;
Jin, Chenjin ;
Cai, Xiaoyu ;
Khaw, Peng T. ;
Foster, Paul J. .
OPHTHALMOLOGY, 2007, 114 (08) :1513-1519