Low-dose sirolimus-eluting hydroxyapatite coating on stents does not increase platelet activation and adhesion ex vivo

被引:12
作者
Alviar, Carlos L. [1 ,2 ]
Tellez, Armando [1 ]
Wang, Michael [3 ]
Potts, Pamela [4 ]
Smith, Doug [5 ]
Tsui, Manus [5 ]
Budzynski, Wladyslaw [5 ]
Raizner, Albert E. [6 ]
Kleiman, Neal S. [6 ]
Lev, Eli I. [6 ]
Granada, Juan F. [1 ]
Kaluza, Greg L. [1 ]
机构
[1] Cardiovasc Res Fdn, Skirball Ctr Cardiovasc Res, Orangeburg, NY 10962 USA
[2] Columbia Univ, Coll Phys & Surg, St Lukes Roosevelt Hosp Ctr, New York, NY USA
[3] Univ Texas Houston, Houston, TX USA
[4] Texas Heart Inst, Houston, TX 77025 USA
[5] MIV Therapeut Inc, Vancouver, BC, Canada
[6] Methodist DeBakey Heart & Vasc Ctr, Houston, TX USA
关键词
Stents coatings; Hydroxyapatite; Platelet activation; Platelet adhesion; PORCINE CORONARY-ARTERIES; SURFACE-TOPOGRAPHY; STAINLESS-STEEL; SYSTEM; IMPLANTATION; LESIONS; CELLS; TRIAL; ENDOTHELIALIZATION; THROMBOSIS;
D O I
10.1007/s11239-012-0696-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We previously found paclitaxel-eluting polymer-coated stents causing more human platelet-monocyte complex formation than bare metal stents in vitro. Presently, we examined patterns of platelet activation and adhesion after exposure to 6 nanofilm HAp-coated (HAp-nano) stents, 6 HAp-microporous-coated (HAp-micro) stents, 5 HAp sirolimus-eluting microporous-coated (HAp-SES) stents and 5 cobalt-chromium stents (BMS) deployed in an in vitro flow system. Blood obtained from healthy volunteers was circulated and sampled at 0, 10, 30 and 60 min. By flow cytometry, there were no significant differences in P-Selectin expression between the 4 stent types (HAp-nano = 32.5%; HAp-micro = 42.5%, HAp-SES = 10.23%, BMS = 7% change from baseline at 60 min, p = NS); PAC-1 antibody binding (HAp-nano = 11.8%; HAp-micro = 2.9%, HAp-SES = 18%, BMS = 6.4% change from baseline at 60 min, p = NS) or PMC formation (HAp-nano = 21.6%; HAp-micro = 4%, HAp-SES = 6.6%, BMS = 17.4% change from baseline at 60 min, p = NS). The 4 stent types did not differ in the average number of platelet clusters > 10 mu m in diameter by SEM (HAp-nano = 2.39 +/- A 5.75; HAp-micro = 2.26 +/- A 3.43; HAp-SES = 1.93 +/- A 3.24; BMS = 1.94 +/- A 2.41, p = NS). The majority of the struts in each stent group were only mildly covered by platelets, (HAp-nano = 80%, HAp-micro = 61%, HAp-SES = 78% and BMS = 52.1%, p = NS). The HAp-microporous-coated stents (ECD) attracted slightly more proteinaceous material than bare metal stents (HAp-micro = 35% struts with complete protein coverage, P < 0.0001 vs. other 3 stent types). In conclusion, biomimetic stent coating with nanofilm or microporous hydroxyapatite, even when eluting low-dose sirolimus, does not increase the platelet activation in circulating human blood, or platelet adhesion to stent surface when compared to bare metal stents in vitro.
引用
收藏
页码:91 / 98
页数:8
相关论文
共 35 条
[1]   INFLUENCE OF ARTERIAL DAMAGE AND WALL SHEAR RATE ON PLATELET DEPOSITION - EXVIVO STUDY IN A SWINE MODEL [J].
BADIMON, L ;
BADIMON, JJ ;
GALVEZ, A ;
CHESEBRO, JH ;
FUSTER, V .
ARTERIOSCLEROSIS, 1986, 6 (03) :312-320
[2]   Endothelial cell reaction on a biological material [J].
Breithaupt-Faloppa, AC ;
Kleinheinz, J ;
Crivello, O .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2006, 76B (01) :49-55
[3]   Enhanced functions of vascular cells on nanostructured Ti for improved stent applications [J].
Choudhary, Saba ;
Haberstroh, Karen M. ;
Webster, Thomas J. .
TISSUE ENGINEERING, 2007, 13 (07) :1421-1430
[4]   1-Year Results of the Hydroxyapatite Polymer-Free Sirolimus-Eluting Stent for the Treatment of Single De Novo Coronary Lesions The VESTASYNC I Trial [J].
Costa, J. Ribamar, Jr. ;
Abizaid, Alexandre ;
Costa, Ricardo ;
Feres, Fausto ;
Tanajura, Luiz Fernando ;
Abizaid, Andrea ;
Maldonado, Galo ;
Staico, Rodolfo ;
Siqueira, Dimytri ;
Sousa, Amanda G. M. R. ;
Bonan, Raoul ;
Sousa, J. Eduardo .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (05) :422-427
[5]   Preliminary Results of the Hydroxyapatite Nonpolymer-Based Sirolimus-Eluting Stent for the Treatment of Single De Novo Coronary Lesions A First-in-Human Analysis of a Third-Generation Drug-Eluting Stent System [J].
Costa, J. Ribamar, Jr. ;
Abizaid, Alexandre ;
Costa, Ricardo ;
Feres, Fausto ;
Fernando Tanajura, Luis ;
Abizaid, Andrea ;
Alberto Mattos, Luiz ;
Staico, Rodolfo ;
Siqueira, Dimytri ;
Sousa, Amanda G. M. R. ;
Bonan, Raoul ;
Sousa, J. Eduardo .
JACC-CARDIOVASCULAR INTERVENTIONS, 2008, 1 (05) :545-551
[6]   Influence of stent surface topography on the outcomes of patients undergoing coronary stenting:: A randomized double-blind controlled trial [J].
Dibra, A ;
Kastrati, A ;
Mehilli, J ;
Pache, J ;
von Oepen, R ;
Dirschinger, J ;
Schömig, A .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 65 (03) :374-380
[7]  
Fuss C, 2001, J AM COLL CARDIOL, V37, p70A
[8]   Coronary Stents Looking Forward [J].
Garg, Scot ;
Serruys, Patrick W. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (10) :S43-S78
[9]   Patterns of activation and deposition of platelets exposed to the polymeric surface of the paclitaxel eluting stent [J].
Granada, Juan F. ;
Alviar, Carlos L. ;
Wallace-Bradley, David ;
Osteen, Matthew ;
Dave, Bijal ;
Tellez, Armando ;
Win, Htut K. ;
Kleiman, Neal S. ;
Kaluza, Greg L. ;
Lev, Eli I. .
JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2010, 29 (01) :60-69
[10]   Platelet activation and high tissue factor level predict acute stent thrombosis in pig coronary arteries:: Prothrombogenic response of drug-eluting or bare stent implantation within the first 24 hours [J].
Gyoengyoesi, Mariann ;
Strehblow, Christoph ;
Sperker, Wolfgang ;
Hevesi, Akos ;
Garamvolgyi, Rita ;
Petrasi, Zsolt ;
Pavo, Noemi ;
Ferdinandy, Peter ;
Csonka, Csaba ;
Csont, Tamas ;
Sylvn, Christer ;
Declerck, Paul J. ;
Pavo, Irnre ;
Wojta, Johann ;
Glogar, Dietmar ;
Huber, Kurt .
THROMBOSIS AND HAEMOSTASIS, 2006, 96 (02) :202-209