Qualitative detection of desmopressin in plasma by liquid chromatography-tandem mass spectrometry

被引:21
|
作者
Esposito, Simone [1 ]
Deventer, Koen [1 ]
T'Sjoen, Guy [2 ]
Vantilborgh, Anna [3 ]
Delbeke, Frans T. [1 ]
Goessaert, An-Sofie [4 ]
Everaert, Karel [4 ]
Van Eenoo, Peter [1 ]
机构
[1] Univ Ghent, Doping Control Lab, B-9052 Zwijnaarde, Belgium
[2] Ghent Univ Hosp, Dept Endocrinol Androl, Ctr Sexol & Gender Problems, B-9000 Ghent, Belgium
[3] Ghent Univ Hosp, Dept Hematol, B-9000 Ghent, Belgium
[4] Ghent Univ Hosp, Dept Urol, B-9000 Ghent, Belgium
关键词
Desmopressin; Liquid chromatography-mass spectrometry; Doping; Plasma; 1-DEAMINO-8-D-ARGININE VASOPRESSIN; NOCTURNAL POLYURIA; DIABETES-INSIPIDUS; PHARMACOKINETICS; EXCRETION; ADULTS;
D O I
10.1007/s00216-011-5697-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This work describes a liquid chromatography-electrospray tandem mass spectrometry method for detection of desmopressin in human plasma in the low femtomolar range. Desmopressin is a synthetic analogue of the antidiuretic hormone arginine vasopressin and it might be used by athletes as a masking agent in the framework of blood passport controls. Therefore, it was recently added by the World Anti-Doping Agency to the list of prohibited substances in sport as a masking agent. Mass spectrometry characterization of desmopressin was performed with a high-resolution Orbitrap-based mass spectrometer. Detection of the peptide in the biological matrix was achieved using a triple-quadrupole instrument with an electrospray ionization interface after protein precipitation, weak cation solid-phase extraction and high performance liquid chromatography separation with an octadecyl reverse-phase column. Identification of desmopressin was performed using three product ions, m/z 328.0, m/z 120.0, and m/z 214.0, from the parent ion, m/z 535.5. The extraction efficiency of the method at the limit of detection was estimated as 40% (n = 10), the ion suppression as 5% (n = 10), and the limit of detection was 50 pg/ml (signal-to-noise ratio greater than 3). The selectivity of the method was verified against several endogenous and synthetic desmopressin-related peptides. The performance and the applicability of the method were tested by analysis of clinical samples after administration of desmopressin via intravenous, oral, and intranasal routes. Only after intravenous administration could desmopressin be successfully detected.
引用
收藏
页码:2789 / 2796
页数:8
相关论文
共 50 条
  • [41] Liquid chromatography-tandem mass spectrometry assay for the quantitation of β-dihydroartemisinin in rat plasma
    Xing, Jie
    Yan, Hong-Xia
    Wang, Rui-Li
    Zhang, Li-Feng
    Zhang, Shu-Qiu
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 202 - 207
  • [42] Determination of guanidinoacetate and creatine in urine and plasma by liquid chromatography-tandem mass spectrometry
    Cognat, SB
    Cheillan, D
    Piraud, M
    Roos, B
    Jakobs, C
    Viany-Saban, C
    CLINICAL CHEMISTRY, 2004, 50 (08) : 1459 - 1461
  • [43] Quantification of ketamine and norketamine in bovine plasma by liquid chromatography-tandem mass spectrometry
    Devreese, Mathias
    Rodrigo, Diego
    Schauvliege, Stijn
    Gasthuys, Frank
    De Backer, Patrick
    Croubels, Siska
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2015, 12 (08) : 1357 - 1362
  • [44] Determination of ecliptasaponin A in rat plasma and tissues by liquid chromatography-tandem mass spectrometry
    Zhao, Jing
    Liu, Erwei
    Han, Lifeng
    Wang, Linlin
    Zhang, Yi
    Wang, Tao
    Fang, Shiming
    Gao, Xiumei
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (06) : 846 - 851
  • [45] Quantification of Clenbuterol in Human Plasma and Urine by Liquid Chromatography-Tandem Mass Spectrometry
    M. Thevis
    T. Schebalkin
    A. Thomas
    W. Schänzer
    Chromatographia, 2005, 62 : 435 - 439
  • [46] Quantitation of astragaloside IV in rat plasma by liquid chromatography-tandem mass spectrometry
    Yan, LX
    Guo, DA
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 824 (1-2): : 244 - 248
  • [47] Globotriaosylceramide isoform profiles in human plasma by liquid chromatography-tandem mass spectrometry
    Nelson, BC
    Roddy, T
    Araghi, S
    Wilkens, D
    Thomas, JJ
    Zhang, K
    Sung, CCC
    Richards, SM
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 805 (01): : 127 - 134
  • [48] Determination of cinacalcet hydrochloride in human plasma by liquid chromatography-tandem mass spectrometry
    Yang, Fen
    Wang, Hongyun
    Zhao, Qian
    Liu, Hongzhong
    Hu, Pei
    Jiang, Ji
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 61 : 237 - 241
  • [49] Erratum to: Quantification of micafungin in human plasma by liquid chromatography-tandem mass spectrometry
    Giuliana Cangemi
    Sebastiano Barco
    Roberto Bandettini
    Elio Castagnola
    Analytical and Bioanalytical Chemistry, 2014, 406 : 3249 - 3249
  • [50] Determination of bicyclol in dog plasma using liquid chromatography-tandem mass spectrometry
    Sheng, Li
    Hu, Jinping
    Wang, Baolian
    Chen, Hui
    Li, Yan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (23): : 2106 - 2110