Computed-tomography-guided punctures using a new guidance device

被引:13
作者
Magnusson, A [1 ]
Radecka, E [1 ]
Lönnemark, M [1 ]
Raland, H [1 ]
机构
[1] Univ Uppsala Hosp, Dept Diagnost Radiol, SE-75185 Uppsala, Sweden
关键词
biopsies; computed tomography- (CT-) guidance; laser guide; technology;
D O I
10.1080/02841850510021508
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate a new adjunctive guidance device, a puncture guide, constructed to simplify computed tomography (CT)-guided punctures and to make the procedure more accurate and safe. Material and Methods: 17 patients referred for CT-guided punctures were included in the study. There were 10 thoracic and 7 abdominal or pelvic lesions with a mean maximum diameter of 29 - 18 mm. All punctures were performed using a laser guide combined with the new device. The needle guide created a streak artefact in the image, indicating the needle path. Results: The puncture was successful at the first attempt in 15 of the 17 patients. The artefact was visible in all patients, and in the majority there was a distinct artefact reaching from the entry point to the lesion. The deviation between the angle of the streak artefact and the final angle of the needle was 1.1. Conclusion: The benefits of the puncture guide were the artefact pointing at the target, the needle support, and accuracy when performing CT-guided punctures.
引用
收藏
页码:505 / 509
页数:5
相关论文
共 7 条
[1]   Multicenter evaluation of a new laser guidance system for computed tomography intervention [J].
Brabrand, K ;
Aalokken, TM ;
Krombach, GA ;
Günther, RW ;
Tariq, R ;
Magnusson, A ;
Lindgren, PG .
ACTA RADIOLOGICA, 2004, 45 (03) :308-312
[2]   A LIGHT-GUIDANCE SYSTEM TO BE USED FOR CT-GUIDED BIOPSY [J].
FREDERICK, PR ;
BROWN, TH ;
MILLER, MH ;
BAHR, AL ;
TAYLOR, KH .
RADIOLOGY, 1985, 154 (02) :535-536
[3]   PRECISE BIOPSY LOCALIZATION BY COMPUTED TOMOGRAPHY [J].
HAAGA, JR ;
ALFIDI, RJ .
RADIOLOGY, 1976, 118 (03) :603-607
[4]  
MAGNUSSON A, 1991, ACTA RADIOL, V32, P83
[5]   CT-GUIDED ASPIRATIONS FOR THE BODY - COMPARISON OF HAND GUIDANCE WITH STEREOTAXIS [J].
ONIK, G ;
COSMAN, ER ;
WELLS, TH ;
GOLDBERG, HI ;
MOSS, AA ;
COSTELLO, P ;
KANE, RA ;
HODDICK, WI ;
DEMAS, B .
RADIOLOGY, 1988, 166 (02) :389-394
[6]   NEW DEVICE FOR CT-TARGETED PERCUTANEOUS PUNCTURES [J].
OZDOBA, C ;
VOIGT, K ;
NUSSLIN, F .
RADIOLOGY, 1991, 180 (02) :576-578
[7]   COMPREHENSIVE APPROACH TO CT-GUIDED PROCEDURES WITH A HAND-HELD GUIDANCE DEVICE [J].
PALESTRANT, AM .
RADIOLOGY, 1990, 174 (01) :270-272