PPG2ABP: Translating Photoplethysmogram (PPG) Signals to Arterial Blood Pressure (ABP) Waveforms

被引:51
作者
Ibtehaz, Nabil [1 ]
Mahmud, Sakib [2 ]
Chowdhury, Muhammad E. H. [2 ]
Khandakar, Amith [2 ]
Khan, Muhammad Salman [2 ]
Ayari, Mohamed Arselene [3 ,4 ]
Tahir, Anas M. [5 ]
Rahman, M. Sohel [6 ]
机构
[1] Purdue Univ, Dept Comp Sci, W Lafayette, IN 47907 USA
[2] Qatar Univ, Dept Elect Engn, Doha, Qatar
[3] Qatar Univ, Dept Civil & Architectural Engn, Doha, Qatar
[4] Qatar Univ, Technol Innovat & Engn Educ Unit TIEE, Doha, Qatar
[5] Univ British Columbia, Dept Elect & Comp Engn, Vancouver, BC V6T 1Z4, Canada
[6] BUET, Dept CSE, ECE Bldg, Dhaka 1205, Bangladesh
来源
BIOENGINEERING-BASEL | 2022年 / 9卷 / 11期
关键词
blood pressure; cuff-less blood pressure; mobile health; Photoplethysmogram (PPG); regression;
D O I
10.3390/bioengineering9110692
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Cardiovascular diseases are one of the most severe causes of mortality, annually taking a heavy toll on lives worldwide. Continuous monitoring of blood pressure seems to be the most viable option, but this demands an invasive process, introducing several layers of complexities and reliability concerns due to non-invasive techniques not being accurate. This motivates us to develop a method to estimate the continuous arterial blood pressure (ABP) waveform through a non-invasive approach using Photoplethysmogram (PPG) signals. We explore the advantage of deep learning, as it would free us from sticking to ideally shaped PPG signals only by making handcrafted feature computation irrelevant, which is a shortcoming of the existing approaches. Thus, we present PPG2ABP, a two-stage cascaded deep learning-based method that manages to estimate the continuous ABP waveform from the input PPG signal with a mean absolute error of 4.604 mmHg, preserving the shape, magnitude, and phase in unison. However, the more astounding success of PPG2ABP turns out to be that the computed values of Diastolic Blood Pressure (DBP), Mean Arterial Pressure (MAP), and Systolic Blood Pressure (SBP) from the estimated ABP waveform outperform the existing works under several metrics (mean absolute error of 3.449 +/- 6.147 mmHg, 2.310 +/- 4.437 mmHg, and 5.727 +/- 9.162 mmHg, respectively), despite that PPG2ABP is not explicitly trained to do so. Notably, both for DBP and MAP, we achieve Grade A in the BHS (British Hypertension Society) Standard and satisfy the AAMI (Association for the Advancement of Medical Instrumentation) standard.
引用
收藏
页数:17
相关论文
共 32 条
[31]   MLP-BP: A novel framework for cuffless blood pressure measurement with PPG and ECG signals based on MLP-Mixer neural networks [J].
Huang, Bin ;
Chen, Weihai ;
Lin, Chun-Liang ;
Juang, Chia-Feng ;
Wang, Jianhua .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 73
[32]   Investigation of photoplethysmmographic signals and arterial blood oxygen saturation values (SpO2) during blood pressure cuff-induced hypoperfusion [J].
Kyriacou, P. A. ;
Shafqat, K. ;
Pal, S. K. .
PROCEEDINGS OF THE FIFTH IASTED INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2007, :267-271