PPG2ABP: Translating Photoplethysmogram (PPG) Signals to Arterial Blood Pressure (ABP) Waveforms

被引:40
作者
Ibtehaz, Nabil [1 ]
Mahmud, Sakib [2 ]
Chowdhury, Muhammad E. H. [2 ]
Khandakar, Amith [2 ]
Khan, Muhammad Salman [2 ]
Ayari, Mohamed Arselene [3 ,4 ]
Tahir, Anas M. [5 ]
Rahman, M. Sohel [6 ]
机构
[1] Purdue Univ, Dept Comp Sci, W Lafayette, IN 47907 USA
[2] Qatar Univ, Dept Elect Engn, Doha, Qatar
[3] Qatar Univ, Dept Civil & Architectural Engn, Doha, Qatar
[4] Qatar Univ, Technol Innovat & Engn Educ Unit TIEE, Doha, Qatar
[5] Univ British Columbia, Dept Elect & Comp Engn, Vancouver, BC V6T 1Z4, Canada
[6] BUET, Dept CSE, ECE Bldg, Dhaka 1205, Bangladesh
来源
BIOENGINEERING-BASEL | 2022年 / 9卷 / 11期
关键词
blood pressure; cuff-less blood pressure; mobile health; Photoplethysmogram (PPG); regression;
D O I
10.3390/bioengineering9110692
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Cardiovascular diseases are one of the most severe causes of mortality, annually taking a heavy toll on lives worldwide. Continuous monitoring of blood pressure seems to be the most viable option, but this demands an invasive process, introducing several layers of complexities and reliability concerns due to non-invasive techniques not being accurate. This motivates us to develop a method to estimate the continuous arterial blood pressure (ABP) waveform through a non-invasive approach using Photoplethysmogram (PPG) signals. We explore the advantage of deep learning, as it would free us from sticking to ideally shaped PPG signals only by making handcrafted feature computation irrelevant, which is a shortcoming of the existing approaches. Thus, we present PPG2ABP, a two-stage cascaded deep learning-based method that manages to estimate the continuous ABP waveform from the input PPG signal with a mean absolute error of 4.604 mmHg, preserving the shape, magnitude, and phase in unison. However, the more astounding success of PPG2ABP turns out to be that the computed values of Diastolic Blood Pressure (DBP), Mean Arterial Pressure (MAP), and Systolic Blood Pressure (SBP) from the estimated ABP waveform outperform the existing works under several metrics (mean absolute error of 3.449 +/- 6.147 mmHg, 2.310 +/- 4.437 mmHg, and 5.727 +/- 9.162 mmHg, respectively), despite that PPG2ABP is not explicitly trained to do so. Notably, both for DBP and MAP, we achieve Grade A in the BHS (British Hypertension Society) Standard and satisfy the AAMI (Association for the Advancement of Medical Instrumentation) standard.
引用
收藏
页数:17
相关论文
共 26 条
  • [1] Pervasive blood pressure monitoring using Photoplethysmogram (PPG) sensor
    Riaz, Farhan
    Azad, Muhammad Ajmal
    Arshad, Junaid
    Imran, Muhammad
    Hassan, Ali
    Rehman, Saad
    FUTURE GENERATION COMPUTER SYSTEMS-THE INTERNATIONAL JOURNAL OF ESCIENCE, 2019, 98 : 120 - 130
  • [2] On Time Blood Pressure Prediction with the Use of PPG Signals
    Czerwinski, Dariusz
    Wojcicki, Piotr
    Zientarski, Tomasz
    2017 INTERNATIONAL CONFERENCE ON ELECTROMAGNETIC DEVICES AND PROCESSES IN ENVIRONMENT PROTECTION WITH SEMINAR APPLICATIONS OF SUPERCONDUCTORS (ELMECO & AOS), 2017,
  • [3] NABNet: A Nested Attention-guided BiConvLSTM network for a robust prediction of Blood Pressure components from reconstructed Arterial Blood Pressure waveforms using PPG and ECG signals
    Mahmud, Sakib
    Ibtehaz, Nabil
    Khandakar, Amith
    Rahman, M. Sohel
    Gonzales, Antonio JR.
    Rahman, Tawsifur
    Hossain, Md Shafayet
    Hossain, Md. Sakib Abrar
    Faisal, Md. Ahasan Atick
    Abir, Farhan Fuad
    Musharavati, Farayi
    Chowdhury, Muhammad E. H.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 79
  • [4] Continuous Peripheral Blood Pressure Measurement with ECG and PPG Signals at Fingertips
    Lee, Kar Mun
    Qian, Zhengyang
    Yabuki, Ryosuke
    Du, Bang
    Kino, Hisashi
    Fukushima, Takafumi
    Kiyoyama, Koji
    Tanaka, Tetsu
    2018 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS): ADVANCED SYSTEMS FOR ENHANCING HUMAN HEALTH, 2018, : 471 - 474
  • [5] Gender Recognition from PPG Signals of People with Different Blood Pressure
    Aydemir, Tugba
    Sahin, Mehmet
    Aydemir, Onder
    29TH IEEE CONFERENCE ON SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS (SIU 2021), 2021,
  • [6] Blood Pressure Estimation Based on PPG and ECG Signals Using Knowledge Distillation
    Tang, Hui
    Ma, Gang
    Qiu, Lishen
    Zheng, Lesong
    Bao, Rui
    Liu, Jing
    Wang, Lirong
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2024, 15 (01) : 39 - 51
  • [7] Continual Learning for Cuffless Blood Pressure Measurement using PPG and ECG Signals
    Zhang, Chunlin
    Shen, Zhan
    Ding, Xiaorong
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [8] Continuous blood pressure prediction system using Conv-LSTM network on hybrid latent features of photoplethysmogram (PPG) and electrocardiogram (ECG) signals
    Kamanditya, Bharindra
    Fuadah, Yunendah Nur
    Mahardika T., Nurul Qashri
    Lim, Ki Moo
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [9] Blood Pressure Estimation Based on PPG and ECG Signals Using Knowledge Distillation
    Hui Tang
    Gang Ma
    Lishen Qiu
    Lesong Zheng
    Rui Bao
    Jing Liu
    Lirong Wang
    Cardiovascular Engineering and Technology, 2024, 15 : 39 - 51
  • [10] Evaluating and Visualizing the Contribution of ECG Characteristic Waveforms for PPG-Based Blood Pressure Estimation
    Ma, Gang
    Chen, Yuhang
    Zhu, Wenliang
    Zheng, Lesong
    Tang, Hui
    Yu, Yong
    Wang, Lirong
    MICROMACHINES, 2022, 13 (09)