Pre-drilling and self-drilling pins screw-bone fixation stress interaction analysis induced by uniaxial compression loading

被引:1
作者
Chee, Lim Pei [1 ]
Bin Daud, Ruslizam [1 ]
Khan, Shah Fenner Khan Bin Mohamad [1 ]
Zain, Nurul Alia Md [2 ,3 ]
Abdullah, Shamini [2 ,3 ]
Bajuri, Yazid [4 ]
机构
[1] Univ Malaysia Perlis, Sch Mechatron Engn, Pauh Putra Campus, Arau 02600, Perlis, Malaysia
[2] Inst Math, Pauh Putra Campus, Arau 02600, Perlis, Malaysia
[3] Ctr Int Languages, Pauh Putra Campus, Arau 02600, Perlis, Malaysia
[4] Univ Kebangsaan Malaysia, UKM Med Ctr, Dept Orthopaed & Traumatol, Kuala Lumpur, Malaysia
来源
MALAYSIAN JOURNAL OF FUNDAMENTAL AND APPLIED SCIENCES | 2019年 / 15卷 / 01期
关键词
Three-dimensional; uniaxial external fixator; finite element analysis; FINITE-ELEMENT; FORCES; FEMUR; PLATE;
D O I
10.11113/mjfas.v15n2019.1006
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A newly designed Uniaxial external fixator which functions as a universal fixator in the application of all types of bone fractures is recently introduced by both Hospital Universiti Kebangsaan Malaysia (HUKM) and Universiti Malaysia Perlis (UniMAP). The Investigation is focused on identifying and measuring the performance in terms of strength or weakness of the fixator that is needed before the application to the human body. Hence, this research was conducted to determine the performance of Uniaxial external fixator which was based on geometry using different screw drilling techniques applied during an angled uniaxial compression load. A three-dimensional fixator-bone was constructed using different screw inserting techniques which was then converted into ANSYS v14.5 for the purposes of conducting a finite element analysis (FEA). Axial compressive loading with various degrees from 60 to 6300 N were applied to bone models to stimulate patient's daily activities while 10 to 100 N were applied to fixator models for the purposes of reviewing environmental loading to fixator-bone models. Findings revealed that maximum magnitude which caused deformation for predrilling and self-drilling models were located at the highest pin-bone interaction. Conversely, the maximum magnitude of the von Mises strain and stress was located at the lowest pin-bone interaction by omitting the existence of fixator for both Case 1 and 2. There was no obvious difference in the comparison of both models in terms of deformation. However, predrilling models have higher strain and stress than self-drilling models. In sum, findings indicated that self-drilling models have better performance compared to the predrilling models.
引用
收藏
页码:99 / 108
页数:10
相关论文
共 20 条
  • [1] American Academy of Orthopaedic Surgeons, 2014, NON
  • [2] Effects of thread features in osseo-integrated titanium implants using a statistics-based finite element method
    Ausiello, Pietro
    Franciosa, Pasquale
    Martorelli, Massimo
    Watts, David C.
    [J]. DENTAL MATERIALS, 2012, 28 (08) : 919 - 927
  • [3] Barwick J. F., 2011, FEMUR SHAFT FRACTURE
  • [4] The biomechanical aspects of reconstruction for segmental defects of the mandible: A finite element study to assess the optimisation of plate and screw factors
    Bujtar, Peter
    Simonovics, Janos
    Varadi, Karoly
    Sandor, George K. B.
    Avery, C. M. E.
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2014, 42 (06) : 855 - 862
  • [5] Colton C., 2012, SCREWS FORM FUNCTION
  • [6] Dankward H., 2016, AO SURG REFERENCE
  • [7] Finite element evaluation of three methods of stable fixation of condyle base fractures
    de Jesus, G. P.
    Vaz, L. G.
    Gabrielli, M. F. R.
    Passeri, L. A.
    Oliveira, T. V.
    Noritomi, P. Y.
    Juergens, P.
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2014, 43 (10) : 1251 - 1256
  • [8] Bone properties affect loosening of half-pin external fixators at the pin-bone interface
    Donaldson, Finn E.
    Pankaj, Pankaj
    Simpson, A. Hamish R. W.
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (10): : 1764 - 1770
  • [9] Internal femoral forces and moments during running: Implications for stress fracture development
    Edwards, W. Brent
    Gillette, Jason C.
    Thomas, Joshua M.
    Derrick, Timothy R.
    [J]. CLINICAL BIOMECHANICS, 2008, 23 (10) : 1269 - 1278
  • [10] The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysis
    Eraslan, Oguz
    Inan, Oezguer
    [J]. CLINICAL ORAL INVESTIGATIONS, 2010, 14 (04) : 411 - 416