Scanned proton radiotherapy for mobile targets-the effectiveness of re-scanning in the context of different treatment planning approaches and for different motion characteristics

被引:145
作者
Knopf, Antje-Christin [1 ]
Hong, Theodore S. [2 ]
Lomax, Antony [1 ,3 ]
机构
[1] Paul Scherrer Inst, Ctr Proton Therapy, Villigen, Switzerland
[2] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Radiat Oncol, Boston, MA USA
[3] ETH, Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
PAUL-SCHERRER-INSTITUTE; PARTICLE THERAPY; ORGAN MOTION; RESPIRATORY MOTION; MOVING TARGETS; MANAGEMENT; BEAMS; IRRADIATION; GANTRY;
D O I
10.1088/0031-9155/56/22/016
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The most advanced delivery technique for proton radiotherapy is active spot scanning. So far, predominantly static targets have been treated with active spot scanning, since mobile targets in combination with dynamic treatment delivery can lead to interplay effects, causing inhomogeneous dose distributions. One way to mitigate motion effects is re-scanning. In this study we investigate the effectiveness of re-scanning in relation to different plan parameters (number of fields, field directions, number of re-scans) as well as in respect to different motion parameters (motion amplitude, motion starting phase). A systematic study was performed for three liver patients, for which ten different plans have been calculated, respectively. The treatment plans were evaluated for three different scenarios (static, motion/single-scan-delivery, motion/re-scanned-delivery). The choice of motion parameters was based on an evaluation of the 4D CT data sets of the three patients. It is shown that the effect of motion/re-scanning per fraction is largest the fewer fields per plan are used and the more the field direction differs from the main motion direction. For amplitudes up to 6 mm, re-scanning may not be required if multiple fields are used, since only dose blurring effects appear that cannot be compensated by re-scanning. For larger motion amplitudes two planning strategies are proposed.
引用
收藏
页码:7257 / 7271
页数:15
相关论文
共 20 条
[1]   The influence of the optimization starting conditions on the robustness of intensity-modulated proton therapy plans [J].
Albertini, F. ;
Hug, E. B. ;
Lomax, A. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (10) :2863-2878
[2]   Motion in radiotherapy: particle therapy [J].
Bert, C. ;
Durante, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (16) :R113-R114
[3]   Quantification of interplay effects of scanned particle beams and moving targets [J].
Bert, Christoph ;
Groezinger, Sven O. ;
Rietzel, Eike .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (09) :2253-2265
[4]   4D treatment planning for scanned ion beams [J].
Bert, Christoph ;
Rietzel, Eike .
RADIATION ONCOLOGY, 2007, 2 (1)
[5]   Four-dimensional proton treatment planning for lung tumors [J].
Engelsman, M ;
Rietzel, E ;
Kooy, HM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (05) :1589-1595
[6]   Moving target irradiation with fast rescanning and gating in particle therapy [J].
Furukawa, Takuji ;
Inaniwa, Taku ;
Sato, Shinji ;
Shirai, Toshiyuki ;
Mori, Shinichiro ;
Takeshita, Eri ;
Mizushima, Kota ;
Himukai, Takeshi ;
Noda, Koji .
MEDICAL PHYSICS, 2010, 37 (09) :4874-4879
[7]   The management of respiratory motion in radiation oncology report of AAPM Task Group 76 [J].
Keall, Paul J. ;
Mageras, Gig S. ;
Balter, James M. ;
Emery, Richard S. ;
Forster, Kenneth M. ;
Jiang, Steve B. ;
Kapatoes, Jeffrey M. ;
Low, Daniel A. ;
Murphy, Martin J. ;
Murray, Brad R. ;
Ramsey, Chester R. ;
Van Herk, Marcel B. ;
Vedam, S. Sastry ;
Wong, John W. ;
Yorke, Ellen .
MEDICAL PHYSICS, 2006, 33 (10) :3874-3900
[8]  
KNOPF A, 2011, DREILL WIEN
[9]   Organ motion and its management [J].
Langen, KM ;
Jones, DTL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (01) :265-278
[10]  
Lomax A.J., 2008, PROTON CHARGED PARTI