Determination of octreotide and assessment of matrix effects in human plasma using ultra high performance liquid chromatography-tandem mass spectrometry

被引:36
作者
Ismaiel, Omnia A. [3 ]
Zhang, Tianyi [2 ]
Jenkins, Rand [2 ]
Karnes, H. Thomas [1 ]
机构
[1] Virginia Commonwealth Univ, Sch Pharm, Dept Pharmaceut, Richmond, VA 23284 USA
[2] PPD, Richmond, VA USA
[3] Zagazig Univ, Fac Pharm, Dept Analyt Chem, Zagazig, Egypt
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2011年 / 879卷 / 22期
关键词
Oncology; UPLC; Peptide; Ion suppression; Micro elution; Cancer; Phospholipids; MONITORING PHOSPHOLIPIDS; QUANTITATIVE BIOANALYSIS; PEPTIDES; LC/MS/MS; SUPPRESSION; ESI;
D O I
10.1016/j.jchromb.2011.05.039
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A selective UHPLC-MS/MS method for determination of the therapeutic peptide octreotide in human plasma was developed and validated. This assay used a UHPLC C-18 column with 1.7 mu m particle size for efficient separation and an ion-exchange SPE for selective extraction. Octreotide and its labeled internal standard, [(13)C(6)Phe(3)] octreotide, were extracted from human plasma using a simple Oasis (R) WCX mu Elution SPE method and analyzed with a total chromatographic run time of 7.5 min. Matrix effects were studied during method development by direct monitoring of representative phospholipids. On-line removal of phospholipids using column switching and pre-column back-flushing was carried out to trap and remove any residual phospholipid matrix interferences. The UHPLC column provided baseline separation between the analyte and matrix peaks. The chromatographic conditions yielded optimal retention and excellent peak shape for both the analyte and internal standard. The assay was linear in the concentration range of 0.025-25.0 ng/ml, inter- and intra-assay precision and accuracy were within 6.1% and +/-1.93%, respectively. Recovery was similar to 73%. Post-extraction addition experiments showed that matrix effects were less than 4%. This method for octreotide in human plasma has been validated and utilized to support of clinical pharmacokinetic studies. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:2081 / 2088
页数:8
相关论文
共 18 条
[1]   Systematic and comprehensive strategy for reducing matrix effects in LC/MS/MS analyses [J].
Chambers, Erin ;
Wagrowski-Diehl, Diane M. ;
Lu, Ziling ;
Mazzeo, Jeffrey R. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2) :22-34
[2]   Nonparametric analysis of the absorption profile of octreotide in rabbits from long-acting release formulation OncoLAR [J].
Comets, E ;
Mentré, F ;
Nimmerfall, F ;
Kawai, R ;
Mueller, I ;
Marbach, P ;
Vonderscher, J .
JOURNAL OF CONTROLLED RELEASE, 1999, 59 (02) :197-205
[3]   Protein identification using 2D-LC-MS/MS [J].
Delahunty, C ;
Yates, JR .
METHODS, 2005, 35 (03) :248-255
[4]   Monitoring phospholipids for assessment of matrix effects in a liquid chromatography-tandem hydrocodone mass spectrometry method for and pseudoephedrine in human plasma [J].
Ismaiel, Omnia A. ;
Halquist, Matthew S. ;
Elmamly, Magda Y. ;
Shalaby, Abdalla ;
Karnes, H. Thomas .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 859 (01) :84-93
[5]   Monitoring phospholipids for assessment of ion enhancement and ion suppression in ESI and APCI LC/MS/MS for chlorpheniramine in human plasma and the importance of multiple source matrix effect evaluations [J].
Ismaiel, Omnia A. ;
Halquist, Matthew S. ;
Elmamly, Magda Y. ;
Shalaby, Abdalla ;
Karnes, H. Thomas .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 875 (02) :333-343
[6]   Multidimensional separation of peptides for effective proteomic analysis [J].
Issaq, HJ ;
Chan, KC ;
Janini, GM ;
Conrads, TP ;
Veenstra, TD .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 817 (01) :35-47
[7]  
Jemal M, 2000, BIOMED CHROMATOGR, V14, P422, DOI 10.1002/1099-0801(200010)14:6<422::AID-BMC25>3.0.CO
[8]  
2-I
[9]   Determination of long-acting release octreotide, an octapeptide analogue of in human plasma by liquid somatostation, chromatography/tandem mass spectrometry [J].
Jiang, Yao ;
Wang, Jiang ;
Wang, Yingwu ;
Du, Xiaolin ;
Zhang, Yunhui ;
Fawcett, J. Paul ;
Gu, Jingkai .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (24) :3982-3986
[10]   Liquid chromatography-mass spectrometry/mass spectrometry method development for drug metabolism studies: Examining lipid matrix ionization effects in plasma [J].
Little, JL ;
Wempe, MF ;
Buchanan, CM .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 833 (02) :219-230