Modeling and Analysis of the Dynamic Response of an Off-Grid Synchronous Generator Driven Micro Hydro Power System

被引:1
|
作者
Ali, Waqas [1 ]
Farooq, Haroon [1 ]
Rasool, Akhtar [2 ]
Sajjad, Intisar A. [3 ]
Cui, Zhenhua [4 ]
Ning, Lin [4 ]
机构
[1] Univ Engn & Technol, Dept Elect Engn, RCET Campus, Lahore, Pakistan
[2] Sharif Coll Engn & Technol, Dept Elect Engn, Lahore, Pakistan
[3] Univ Engn & Technol, Dept Elect Engn, Taxila, Pakistan
[4] Natl Res Inst Rural Elect, Hangzhou Reg Ctr HRC Small Hydro Power, Minist Water Resources, Hangzhou, Peoples R China
来源
INTERNATIONAL JOURNAL OF RENEWABLE ENERGY DEVELOPMENT-IJRED | 2021年 / 10卷 / 02期
基金
国家重点研发计划;
关键词
Micro Hydro Power; Off-grid; No Load; Full Load; Overloud; Normal; Abnormal; Response; Regulation; Modeling; Simulation; RES PLANTS; SIMULATION;
D O I
10.14710/ijred.2021.33567
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper models and analyses the dynamic response of a synchronous generator driven off-grid micro hydro power system Simulink tool of MATLAB software. The result s are assessed from various perspectives including regulation through no load to full load and overload scenarios under normal and abnormal operating conditions. The investigation under the normal conditions of no load, linearly changing load and full load divulges that the system operates in a satisfactory manner as generator voltage and frequency remain approximately constant at 1 pu. However, at full load generator voltage and frequency drop 3% and 0.5% respectively from its nominal values but remain within prescribed standard IEC limits. The results also expose that the abnormal conditions produced by abrupt changes in load, system faults and severe overload, cause the unwonted variations in the magnitude of generator parameters. Moreover, the study reveals that the system stability significantly enhances when the system is run at full load because the regulation time to fix the variations in the generator parameters; except input mechanical power; decreases, e.g. from 4.1 sec to 0.8 sec for generator voltage, with the increase in the loading from quarter to full load respectively at unity power factor. Further, it is also observed that the regulation time rises, e.g. from 0.8 sec to 1.3 sec for generator voltage. with the reduction in load power factor from unity to 0.8, respectively. Thus. proper protection. to cater for increased fault current at full load and power factor correction must be provided to improve the system stability and protection. Furthermore, it is also concluded that the over loading in any case should be strongly avoided in this type of system and it should never be allowed to exceed 20% of the full load value to avoid system failure.
引用
收藏
页码:373 / 384
页数:12
相关论文
共 50 条
  • [31] Research and Design of Off-Grid Solar PV Power Generation LED Display System
    Wu Dengsheng
    Wang Lidi
    Wu Xiuhua
    Meng Xiaofang
    Wang Jun
    Guo Dan
    Wang Hui
    PROCEEDINGS OF THE 28TH CHINESE CONTROL AND DECISION CONFERENCE (2016 CCDC), 2016, : 333 - 337
  • [32] A renewable power system for an off-grid sustainable telescope fueled by solar power, batteries and green hydrogen
    Viole, Isabelle
    Valenzuela-Venegas, Guillermo
    Zeyringer, Marianne
    Sartori, Sabrina
    ENERGY, 2023, 282
  • [33] Modeling and Performance Analysis of Micro-Hydro Generation Controls Considering Power System Stability
    Ali, Waqas
    Farooq, Haroon
    Rehman, Atta Ur
    Farrag, Mohamed E.
    2017 FIRST INTERNATIONAL CONFERENCE ON LATEST TRENDS IN ELECTRICAL ENGINEERING AND COMPUTING TECHNOLOGIES (INTELLECT), 2017,
  • [34] Theoretical modeling and economic analysis of PV and fuel cell energy system for an off-grid green villa in Sidi Bouzid, Tunisia - A case study
    Miled, Amel
    Farhani, Slah
    Askri, Faouzi
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2025, 105 : 932 - 945
  • [35] Small-Signal Modeling of Off-Grid Integrated Energy System Considering Internal Disturbances
    Gan, Nierong
    Wang, Xiaojun
    Zhang, Yizhi
    PROCEEDINGS OF 2019 IEEE 3RD INTERNATIONAL ELECTRICAL AND ENERGY CONFERENCE (CIEEC), 2019, : 1428 - 1433
  • [36] A Hybrid Photovoltaic/Diesel System for Off-Grid Applications in Lubumbashi, DR Congo: A HOMER Pro Modeling and Optimization Study
    Rice, Ilunga Kajila
    Zhu, Hanhua
    Zhang, Cunquan
    Tapa, Arnauld Robert
    SUSTAINABILITY, 2023, 15 (10)
  • [37] Techno-economic Assessment of a Hybrid Off-grid DC System for Combined Heat and Power Generation in Remote Islands
    Kalamaras, Evangelos
    Belekoukia, Meltiani
    Lin, Zhengyu
    Xu, Bing
    Wang, Huizhi
    Xuan, Jin
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 6315 - 6320
  • [38] Research on active power filter for distributed power system of high speed generator driven by micro-turbine
    Ming, Z
    Wang, FX
    Zheng, W
    Zhang, FG
    2004 International Conference on Power System Technology - POWERCON, Vols 1 and 2, 2004, : 788 - 791
  • [39] Review of hybrid renewable energy systems with comparative analysis of off-grid hybrid system
    Sawle, Yashwant
    Gupta, S. C.
    Bohre, Aashish Kumar
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 81 : 2217 - 2235
  • [40] Design and Implementation of a Prototype Underwater Turbine Generator System for Renewable Micro Hydro Power Energy
    Wang, Li
    Chen, Su-Jen
    Jen, Shen-Ron
    Li, Hao-Wen
    2012 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING (IAS), 2012,