Benefits of Position-Sensitive Detectors for Radioactive Source Detection

被引:9
作者
Lingenfelter, Daniel J. [1 ]
Fessler, Jeffrey A. [1 ]
Scott, Clayton D. [1 ]
He, Zhong [2 ]
机构
[1] Univ Michigan, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
关键词
Asymptotic; detection; generalized likelihood ratio test (GLRT); LIKELIHOOD; AREA;
D O I
10.1109/TSP.2010.2051805
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
There are many systems for counting photons such as gamma-rays emitted from radioactive sources. Many of these systems are also position-sensitive, which means that the system provides directional information about recorded events. This paper investigates whether or not the additional information provided by position-sensitive capability improves the performance of detecting a point-source in background. We analyze the asymptotic performance of the generalized likelihood ratio test (GLRT) and a test based on the maximum-likelihood (ML) estimate of the source intensity for systems with and without position-sensitive capability. When the background intensity is known and detector sensitivity is spatially uniform, we prove that position-sensitive capability increases the area under the receiver operating characteristic curve (AUC). For cases when detector sensitivity is nonuniform or background intensity is unknown, we provide numerical results to illustrate the effect of the parameters on detection performance.
引用
收藏
页码:4473 / 4483
页数:11
相关论文
共 18 条
[1]   List-mode likelihood [J].
Barrett, HH ;
White, T ;
Parra, LC .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1997, 14 (11) :2914-2923
[2]   Maximum likelihood approach to joint array detection/estimation [J].
Bethel, RE ;
Bell, KL .
IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 2004, 40 (03) :1060-1072
[3]  
FELDMAN D, 1991, PROBABILITY MATH UNC
[4]   THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36
[5]   3-D position sensitive CdZnTe gamma-ray spectrometers [J].
He, Z ;
Li, W ;
Knoll, GF ;
Wehe, DK ;
Berry, J ;
Stahle, CM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3) :173-178
[6]  
Kay S., 1998, FUNDAMENTALS STAT SI
[7]  
Knoll GF., 1989, Radiation detection and measurement
[8]   Detection of particle sources with directional detector arrays and a mean-difference test [J].
Liu, Z ;
Nehorai, A .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2005, 53 (12) :4472-4484
[9]   Statistical angular resolution limit for point sources [J].
Liu, Zhi ;
Nehorai, Arye .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2007, 55 (11) :5521-5527
[10]   IMAGING RADIOTRACER MODEL PARAMETERS IN PET - A MIXTURE ANALYSIS APPROACH [J].
OSULLIVAN, F .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (03) :399-412