Test of multi-anode photomultiplier tubes for the LHCb scintillator pad detector

被引:9
作者
Aguiló, E
Ballabriga, R
Comerma, A
Garrido, L
Gascón, D
Graciani, R
Graugés, E
Vilasís-Cardona, X
Xirgu, X
Bohner, G
Bonnefoy, R
Borras, D
Cornat, R
Crouau, M
Deschamps, O
Jacquet, P
Lecoq, J
Monteil, S
Perret, P
Reinmuth, G
机构
[1] Univ Autonoma Barcelona, IFAE, E-08970 Cerdanyola Del Valles, Spain
[2] Univ Barcelona, Dept ECM, E-08028 Barcelona, Spain
[3] Univ Ramon Llull, EALS, Barcelona 08022, Spain
[4] Univ Clermont Ferrand, Phys Corpusculaire Lab, CNRS, IN2P3, F-63177 Aubiere, France
关键词
MaPMT; SPD; LHCb;
D O I
10.1016/j.nima.2004.08.116
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The LHCb experiment (The LHCb Technical Proposal, CERN/LHCC 98-4) is designed to study B meson physics in the LHC proton-proton collider at CERN. The Scintillator Pad Detector (SPD) has been designed to complete the calorimeter information performing an e/gamma identification for the experiment level-0 trigger system. The detection technology consists in transmitting scintillation light by means of both Wavelength Shifting and clear fibers to fast multi-anode photomultiplier tubes. In this paper, it is described the instrumentation and setup used to characterize the baseline photomultiplier solution (Hamamatsu R5900-00-M64) together with the scintillators and optical fibers for the SPD at LHCb. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:255 / 264
页数:10
相关论文
共 4 条
  • [1] Mass characterization of MaPMT tubes for the LHCb scintillator pad detector
    Grauges, Eugeni
    Comerma, Albert
    Garrido, Lluis
    Gascon, David
    Garra, Jordi
    Graciani, Ricardo
    Picatoste, Eduard
    Aguilo, Ernest
    Vilasis-Cardona, Xavier
    Gaspar de Valenzuela, Alvaro
    Bohner, Gerard
    Bonnefoy, Romeo
    Borras, David
    Cornat, Remi
    Crouau, Michel
    Deschamps, Olivier
    Jacquet, Philippe
    Lecoq, Jacques
    Monteil, Stephane
    Perret, Pascal
    Reinmuth, Guy
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 572 (01) : 427 - 428
  • [2] Backsplash studies for the Scintillator Pad Detector of LHCb in a tagged-photon test beam
    Garrido, L
    Gascón, D
    Miquel, R
    Peralta, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 484 (1-3) : 333 - 341
  • [3] Behavior of multi-anode photomultipliers in magnetic fields for the LHCb RICH upgrade
    Gambetta, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 824 : 21 - 23
  • [4] Performance of a cluster of multi-anode photomultipliers equipped with lenses for use in a prototype RICH detector
    Albrecht, E
    Baker, J
    Barber, G
    Bibby, J
    Calvi, M
    Charles, M
    Duane, A
    Easo, S
    Eisenhardt, S
    Eklund, L
    French, M
    Gibson, V
    Halley, A
    Halsall, R
    Harnew, N
    John, MJJ
    Katvars, SG
    Libby, J
    Muheim, F
    Paganoni, M
    Petrolini, A
    Playfer, S
    Price, D
    Rademacker, J
    Smale, N
    Topp-Jorgenson, S
    Websdale, D
    Wilkinson, G
    Wotton, SA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 488 (1-2) : 110 - 130