Magneto-controlled flow-injection device for electrochemical immunoassay of alpha-fetoprotein on magnetic beads using redox-active ferrocene derivative polymer nanospheres

被引:11
作者
Li, Bin [1 ,2 ]
Pu, Wenyuan [1 ]
Xu, Houxi [1 ]
Ge, Lilin [1 ]
Kwok, Hang Fai [2 ]
Hu, Lihong [1 ]
机构
[1] Nanjing Univ Chinese Med, Jiangsu Key Lab Funct Subst Chinese Med, 138 Xianlin Ave, Nanjing 215400, Jiangsu, Peoples R China
[2] Univ Macau, Fac Hlth Sci, Inst Translat Med, Ave Univ, Taipa, Macau, Peoples R China
基金
中国国家自然科学基金;
关键词
PHOTOELECTROCHEMICAL SENSING PLATFORM; INFINITE COORDINATION POLYMER; CARCINOEMBRYONIC ANTIGEN; ULTRASENSITIVE DETECTION; IMMUNOSENSING PLATFORM; SIGNAL; BIOSENSORS; SENSITIVITY; PROTEINS; SYSTEMS;
D O I
10.1039/c8an01978a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new electrochemical immunosensing protocol by coupling with a magneto-controlled flow-through microfluidic device was developed for the sensitive detection of alpha-fetoprotein (AFP) on magnetic beads (MB) using ferrocene derivative polymer nanospheres (FDNP) as the electroactive mediators. The immunosensing probe was prepared by covalent conjugation of monoclonal mouse anti-human AFP antibodies with magnetic beads, while the recognition element was constructed by means of immobilizing polyclonal rabbit anti-human AFP antibodies on the redox FDNP. Upon target AFP introduction, the sandwich-type immunoreaction was carried out between the immunosensing probe and the recognition element, and the formed immunocomplex was captured in the detection cell with an external magnet. Ferrocene polymer nanospheres synthesized by infinite coordination polymerization were utilized as the signal-generation tags during the electrochemical measurement. Under optimal conditions, the magneto-controlled flow-through immunosensing platform exhibited good electrochemical responses toward target AFP within a dynamic working range of 0.01-100 ng mL(-1) and with a low detection limit of 5.7 pg mL(-1). The nanoparticles-based sensing systems also gave good reproducibility, high specificity and long-term stability. Moreover, our strategy displayed well-matched accuracy for the analysis of human serum specimens relative to commercial Roche 2010 Electrochemiluminescence (ECL) Automated Analyzer.
引用
收藏
页码:1433 / 1441
页数:9
相关论文
共 60 条
[1]   Pt NPs and DNAzyme functionalized polymer nanospheres as triple signal amplification strategy for highly sensitive electrochemical immunosensor of tumour marker [J].
Chang, Honghong ;
Zhang, Haochun ;
Lv, Jia ;
Zhang, Bing ;
Wei, Wenlong ;
Guo, Jingang .
BIOSENSORS & BIOELECTRONICS, 2016, 86 :156-163
[2]   Alpha-fetoprotein-producing ovarian clear cell adenocarcinoma with fetal gut differentiation: a rare case report and literature review [J].
Chao, Wei-Ting ;
Liu, Chia-Hao ;
Lai, Chiung-Ru ;
Chen, Yi-Jen ;
Chuang, Chi-Mu ;
Wang, Peng-Hui .
JOURNAL OF OVARIAN RESEARCH, 2018, 11
[3]   Enhanced electrochemical sensitivity towards acetaminophen determination using electroactive self-assembled ferrocene derivative polymer nanospheres with multi-walled carbon nanotubes [J].
Chen, Yuan ;
Liu, Xiaoying ;
Wu, Tengteng ;
Hou, Wenli ;
Liu, Meiling ;
Zhang, Youyu ;
Yao, Shouzhuo .
ELECTROCHIMICA ACTA, 2018, 272 :212-220
[4]   Magnetic Bead/Gold Nanoparticle Double-Labeled Primers for Electrochemical Detection of Isothermal Amplified Leishmania DNA [J].
de la Escosura-Muniz, Alfredo ;
Baptista-Pires, Luis ;
Serrano, Lorena ;
Altet, Laura ;
Francino, Olga ;
Sanchez, Armand ;
Merkoci, Arben .
SMALL, 2016, 12 (02) :205-213
[5]   Nanoparticle-Based Immunochemical Biosensors and Assays: Recent Advances and Challenges [J].
Farka, Zdenek ;
Jurik, Tomas ;
Kovar, David ;
Trnkova, Libuse ;
Skladal, Petr .
CHEMICAL REVIEWS, 2017, 117 (15) :9973-10042
[6]   Recent Trends in Metallopolymer Design: Redox-Controlled Surfaces, Porous Membranes, and Switchable Optical Materials Using Ferrocene-Containing Polymers [J].
Gallei, Markus ;
Ruettiger, Christian .
CHEMISTRY-A EUROPEAN JOURNAL, 2018, 24 (40) :10006-10021
[7]   Proximity hybridization-regulated electrogenerated chemiluminescence bioassay of α-fetoprotein via target-induced quenching mechanism [J].
Gao, Hongfang ;
Wang, Xiaofei ;
Li, Man ;
Qi, Honglan ;
Gao, Qiang ;
Zhang, Chengxiao .
BIOSENSORS & BIOELECTRONICS, 2017, 98 :62-67
[8]   Magnetic Bead-Based Reverse Colorimetric Immunoassay Strategy for Sensing Biomolecules [J].
Gao, Zhuangqiang ;
Xu, Mingdi ;
Hou, Li ;
Chen, Guonan ;
Tang, Dianping .
ANALYTICAL CHEMISTRY, 2013, 85 (14) :6945-6952
[9]   Progress on nanostructured electrochemical sensors and their recognition elements for detection of mycotoxins: A review [J].
Goud, K. Yugender ;
Kalisa, Suresh Kumar ;
Kumar, Vanish ;
Tsang, Yiu Fai ;
Lee, S. E. ;
Gobi, K. Vengatajalabathy ;
Kim, Ki-Hyun .
BIOSENSORS & BIOELECTRONICS, 2018, 121 :205-222
[10]   Tyramine-Based Enzymatic Conjugate Repeats for Ultrasensitive Immunoassay Accompanying Tyramine Signal Amplification with Enzymatic Biocatalytic Precipitation [J].
Hou, Li ;
Tang, Yun ;
Xu, Mingdi ;
Gao, Zhuangqiang ;
Tang, Dianping .
ANALYTICAL CHEMISTRY, 2014, 86 (16) :8352-8358