Loop-mediated isothermal amplification (LAMP) for malarial parasites of humans: Would it come to clinical reality as a point-of-care test?

被引:87
作者
Abdul-Ghani, Rashad [1 ,2 ]
Al-Mekhlafi, Abdulsalam M. [2 ]
Karanis, Panagiotis [3 ]
机构
[1] Univ Alexandria, Med Res Inst, Dept Parasitol, Alexandria, Egypt
[2] Sanaa Univ, Dept Parasitol, Fac Med & Hlth Sci, Sanaa, Yemen
[3] Univ Cologne, Inst 2, Sch Med, Med & Mol Parasitol Lab,Ctr Anat, D-50931 Cologne, Germany
关键词
LAMP; Plasmodium; Malaria diagnosis; Point-of care test; POLYMERASE-CHAIN-REACTION; PLASMODIUM-VIVAX SPOROZOITES; LINKED-IMMUNOSORBENT-ASSAY; NATURALLY INFECTED MOSQUITOS; RAPID DIAGNOSTIC-TESTS; IN-VITRO AMPLIFICATION; ANOPHELES-GAMBIAE SL; DNA AMPLIFICATION; SENSITIVE DETECTION; IMMUNORADIOMETRIC ASSAY;
D O I
10.1016/j.actatropica.2012.02.004
中图分类号
R38 [医学寄生虫学]; Q [生物科学];
学科分类号
07 ; 0710 ; 09 ; 100103 ;
摘要
Loop-mediated isothermal amplification (LAMP) is a novel molecular method that accelerates and facilitates DNA amplification and detection under isothermal conditions. It represents a revolution in molecular biology by reducing the high cost, turnaround time and technicality of polymerase chain reaction and other amplification methods. It has been applied for the diagnosis of a variety of viral, bacterial, parasitic and other diseases in the biomedical field. LAMP has been involved in studies concerning the diagnosis of malaria which is still a major cause of morbidity and mortality in different parts of the world. For the success attained with this technology to diagnose human malaria, is it time to think that LAMP-based point-of-care diagnostics come to application to support the diagnosis of clinical malaria cases? The present review deals with the use of LAMP in the diagnosis of malaria and related investigations to make a view on what has been investigated and highlights the future perspectives regarding the possible applications of LAMP in diagnosis of the disease. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:233 / 240
页数:8
相关论文
共 109 条
  • [1] Development of a Reverse Transcriptase Loop-Mediated Isothermal Amplification (LAMP) Assay for the Sensitive Detection of Leishmania Parasites in Clinical Samples
    Adams, Emily R.
    Schoone, Gerard J.
    Ageed, Al Farazdag
    El Safi, Sayda
    Schallig, Henk D. F. H.
    [J]. AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2010, 82 (04) : 591 - 596
  • [2] Strategies for signal amplification in nucleic acid detection
    Andras, SC
    Power, JB
    Cocking, EC
    Davey, MR
    [J]. MOLECULAR BIOTECHNOLOGY, 2001, 19 (01) : 29 - 44
  • [3] Rapid identification of Plasmodium-carrying mosquitoes using loop-mediated isothermal amplification
    Aonuma, Hiroka
    Suzuki, Moerni
    Iseki, Hiroshi
    Perera, Narnal
    Nelson, Bryce
    Igarashi, Ikuo
    Yagi, Takeshi
    Kanuka, Hirotaka
    Fukurnoto, Shinya
    [J]. BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2008, 376 (04) : 671 - 676
  • [4] A single fluorescence-based LAMP reaction for identifying multiple parasites in mosquitoes
    Aonuma, Hiroka
    Yoshimura, Aya
    Kobayashi, Tomomi
    Okado, Kiyoshi
    Badolo, Athanase
    Nelson, Bryce
    Kanuka, Hirotaka
    Fukumoto, Shinya
    [J]. EXPERIMENTAL PARASITOLOGY, 2010, 125 (02) : 179 - 183
  • [5] Detection of malaria sporozoites by standard ELISA and VecTest™ dipstick assay in field-collected anopheline mosquitoes from a malaria endemic site in Ghana
    Appawu, MA
    Bosompem, KM
    Dadzie, S
    McKakpo, US
    Anim-Baidoo, I
    Dykstra, E
    Szumlas, DE
    Rogers, WO
    Koram, K
    Fryauff, DJ
    [J]. TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2003, 8 (11) : 1012 - 1017
  • [6] Plasmodium sp.:: Optimal protocols for PCR detection of low parasite numbers from mosquito (Anopheles sp.) samples
    Arez, AP
    Lopes, D
    Pinto, J
    Franco, AS
    Snounou, G
    do Rosário, VE
    [J]. EXPERIMENTAL PARASITOLOGY, 2000, 94 (04) : 269 - 272
  • [7] Sensitive and specific detection of Cryptosporidium species in PCR-negative samples by loop-mediated isothermal DNA amplification and confirmation of generated LAMP products by sequencing
    Bakheit, Mohammed A.
    Torra, Dena
    Palomino, Lily A.
    Thekisoe, Oriel M. M.
    Mbati, Peter A.
    Ongerth, Jerry
    Karanis, Panagiotis
    [J]. VETERINARY PARASITOLOGY, 2008, 158 (1-2) : 11 - 22
  • [8] Evaluation of a dipstick malaria sporozoite panel assay for detection of naturally infected mosquitoes
    Bangs, MJ
    Rusmiarto, S
    Gionar, YR
    Chan, AST
    Dave, K
    Ryan, JR
    [J]. JOURNAL OF MEDICAL ENTOMOLOGY, 2002, 39 (02) : 324 - 330
  • [10] ELISA ABSORBANCE CUTOFFS METHOD AFFECTS MALARIA SPOROZOITE RATE DETERMINATION IN WILD AFRO-TROPICAL ANOPHELES
    BEIER, JC
    ASIAGO, CM
    ONYANGO, FK
    KOROS, JK
    [J]. MEDICAL AND VETERINARY ENTOMOLOGY, 1988, 2 (03) : 259 - 264