Optimizing experimental parameters in isothermal titration calorimetry

被引:69
作者
Tellinghuisen, J [1 ]
机构
[1] Vanderbilt Univ, Dept Chem, Nashville, TN 37235 USA
关键词
D O I
10.1021/jp053550y
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In isothermal titration calorimetry, the statistical precisions with which the equilibrium constant (K) and reaction enthalpy (Delta H degrees) can be estimated from data for 1:1 binding depend on a number of quantities, key among them being the products c K[M](0) and h Delta H degrees[M](0), the stoichiometry range (R-m, ratio of total titrant X to total titrate M after the last injection), and the number of injections of titrant. A study of the statistical errors as functions of these quantities leads to the following prescription for optimizing throughput and precision: (1) Make 10 injections of titrant. (2) Set the concentrations in accord with the empirical equation R-m = 6.4/c(0.2) + 13/c (but no smaller than 1.1). (3) Make the starting concentration [M](0) as large as possible within the large-signal limits of the instrumentation but limited to c < 10(3) for estimating K. With this procedure, both K and [M](0) are predicted to have relative standard errors < 1% over large ranges of K. Systematic errors in the concentrations, [X](0) and [M](0), are fully compensated by the "site number" or stoichiometry parameter (n). On the other hand, altering and freezing any of the fit parameters leads to a deterioration of the fit quality and to predictable changes in the other parameters. Fit divergence at very small c is avoidable through a simple redefinition of the fit parameters; however, unless n can be fixed from other information, Delta H degrees may be statistically ill-defined in this region.
引用
收藏
页码:20027 / 20035
页数:9
相关论文
共 45 条
[1]   STANDARD ERRORS AND CONFIDENCE-INTERVALS IN NONLINEAR-REGRESSION - COMPARISON OF MONTE-CARLO AND PARAMETRIC STATISTICS [J].
ALPER, JS ;
GELB, RI .
JOURNAL OF PHYSICAL CHEMISTRY, 1990, 94 (11) :4747-4751
[2]  
[Anonymous], 1964, Statistics in Physical Sciences-Estimation, hypothesis testing, and least squares
[3]   Isothermal titration calorimetry of supramolecular polymers [J].
Arnaud, A ;
Bouteiller, L .
LANGMUIR, 2004, 20 (16) :6858-6863
[4]   IMPROVED METHOD FOR OBTAINING THERMAL TITRATION CURVES USING MICROMOLAR QUANTITIES OF PROTEIN [J].
BEAUDETTE, NV ;
LANGERMAN, N .
ANALYTICAL BIOCHEMISTRY, 1978, 90 (02) :693-704
[5]   Cations reduce antimicrobial efficacy of lysozyme-chelator combinations [J].
Boland, JS ;
Davidson, PM ;
Bruce, B ;
Weiss, J .
JOURNAL OF FOOD PROTECTION, 2004, 67 (02) :285-294
[6]   NEW PRECISION THERMOMETRIC TITRATION CALORIMETER [J].
CHRISTEN.JJ ;
IZATT, RM ;
HANSEN, LD .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1965, 36 (06) :779-&
[7]   Isothermal titration calorimetric and electromotive force studies on binding interactions of hydrophobic ethoxylated urethane and sodium dodecyl sulfate of different molecular masses [J].
Dai, S ;
Tam, KC ;
Wyn-Jones, E ;
Jenkins, RD .
JOURNAL OF PHYSICAL CHEMISTRY B, 2004, 108 (16) :4979-4988
[8]   ANALYSIS OF PARAMETER RESOLUTION FROM DERIVATIVES OF BINDING ISOTHERMS [J].
DOYLE, ML ;
SIMMONS, JH ;
GILL, SJ .
BIOPOLYMERS, 1990, 29 (8-9) :1129-1135
[9]   DESCRIPTION OF A NEW GILL TITRATION CALORIMETER FOR THE STUDY OF BIOCHEMICAL REACTIONS .2. OPERATIONAL CHARACTERIZATION OF THE INSTRUMENT [J].
ELHARROUS, M ;
MAYORGA, OL ;
PARODYMORREALE, A .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1994, 5 (09) :1071-1077
[10]   DESCRIPTION OF A NEW GILL TITRATION CALORIMETER FOR THE STUDY OF BIOCHEMICAL REACTIONS .1. ASSEMBLY AND BASIC RESPONSE OF THE INSTRUMENT [J].
ELHARROUS, M ;
GILL, SJ ;
PARODYMORREALE, A .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1994, 5 (09) :1065-1070