Post-gadolinium evaluation of intracranial tumours: a comparative study of Spin Echo, Fast Spin Echo, Gradient Echo T1-weighted sequences, with and without Magnetization Transfer
被引:0
作者:
Aprile, I
论文数: 0引用数: 0
h-index: 0
机构:S Maria della Misericordia Gen Hosp, Dept Neuroradiol, Udine, Italy
Aprile, I
Lavaroni, A
论文数: 0引用数: 0
h-index: 0
机构:S Maria della Misericordia Gen Hosp, Dept Neuroradiol, Udine, Italy
Lavaroni, A
Scott, CA
论文数: 0引用数: 0
h-index: 0
机构:S Maria della Misericordia Gen Hosp, Dept Neuroradiol, Udine, Italy
Scott, CA
Budai, R
论文数: 0引用数: 0
h-index: 0
机构:S Maria della Misericordia Gen Hosp, Dept Neuroradiol, Udine, Italy
Budai, R
Beltrami, CA
论文数: 0引用数: 0
h-index: 0
机构:S Maria della Misericordia Gen Hosp, Dept Neuroradiol, Udine, Italy
Beltrami, CA
Fabris, G
论文数: 0引用数: 0
h-index: 0
机构:S Maria della Misericordia Gen Hosp, Dept Neuroradiol, Udine, Italy
Fabris, G
机构:
[1] S Maria della Misericordia Gen Hosp, Dept Neuroradiol, Udine, Italy
[2] Univ Udine, Inst Pathol, I-33100 Udine, Italy
[3] S Maria della Misericordia Gen Hosp, Dept Neurol Clin Neurophysiol, Udine, Italy
来源:
RIVISTA DI NEURORADIOLOGIA
|
2001年
/
14卷
/
03期
关键词:
brain tumours;
magnetic resonance;
comparative studies;
magnetization transfer contrast;
D O I:
10.1177/197140090101400303
中图分类号:
Q189 [神经科学];
学科分类号:
071006 ;
摘要:
This study compares the use of six different post-gadolinium T1-weighted sequences on intracranial tumours with the aim of evaluating their efficacy in terms of lesion and edema contrast resolution and cortex visualization. Forty-eight intracranial neoplastic lesions were evaluated after contrast media administration by means of the following Tl-weighted sequences: Fast Spin-Echo (FSE), Spin-Echo (SE) and Gradient-Echo (GE) with and without Magnetization Transfer (MT) pulse. For each technique tumour/background contrast resolution (T/B CR), oedema/background contrast resolution (E/B CR) and white matter/grey matter contrast resolution (WM/GM CR) were calculated. GE sequences, with and without MT, showed the lowest contrast resolution values for all parameters. FSE MT sequences showed the highest T/B CR values. SE sequences, instead, showed the best E/B and WM/GM CR values. FSE and SE MT values were intermediate between FSE MT and SE sequences. No sequence had high values for all contrast resolution parameters. The sequence with the best T/B CR was the FSE MT, but that with the best anatomic peritumoural edema and cortex definition was SE. Both FSE MT and SE T1-weighted sequences may be acquired to obtain accurate post-gadolinium tumour evaluation.