Bismuth-tin-film electrodes for Zn(II), Cd(II), and Pb(II) trace analysis

被引:31
作者
Finsgar, Matjaz [1 ]
Petovar, Barbara [1 ]
Vodopivec, Katja [1 ]
机构
[1] Univ Maribor, Fac Chem & Chem Engn, Smetanova Ulica 17, Maribor 2000, Slovenia
关键词
Bismuth-tin-film electrodes; Tin-film electrodes; SnFE; BiSnFE; Modified electrodes; Electrochemical impedance spectroscopy; ANODIC-STRIPPING VOLTAMMETRY; SCREEN-PRINTED ELECTRODES; CARBON ELECTRODE; HEAVY-METALS; ANTIMONY; OXIDE; CADMIUM(II); LEAD; PB; CD;
D O I
10.1016/j.microc.2018.11.036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The focus of this work is the novel development and validation of different in situ formed Bi-Sn-film glassy carbon electrodes (BiSnFEs) with changed BKIII):Sn(II) mass concentration ratios (2:8, 4:6, 6:4, 8:2). These electrodes were formed from solutions with 0.5 mg/L and 1.0 mg/L total Bi(III) and Sn(II) mass concentrations therefore, eight new electrodes were designed. BiSnFEs were compared with pure Bi-film electrodes (BiFEs) and Sn-film electrodes (SnFEs). It was shown that all electrodes tested demonstrated a high degree of selectivity for Zn(II), Cd(II), and Pb(II) determination, with clearly separated stripping peaks. The widest linear concentration range for Zn(II) determination was obtained at 19.6-413.9 pg/L using an electrode with a BKIII):Sn(II) ratio of 0.6:0.4 at 0.5 mg/L total mass concentration. For Cd(II) and Pb(II), the widest linear concentration range was measured using pure SnFE at 0.5 mg/L. Moreover, different BiSnFEs significantly increased the method's sensitivity for Zn(II), Cd(II), and Pb(II) determination compared with pure BiFEs and SnFEs. The lowest LOD values were measured using pure BiFEs; however, the LOD values were also relatively low for certain BiSnFEs. An electrode with a Bi(Ill):Sn(II) ratio of 0.4:0.6 at 0.5 mg/L total mass concentration (Le. a final solution containing 0.2 mg/L Bi(III) and 0.3 mg/L Snap to form an in situ electrode) demonstrated the greatest accuracy and precision for simultaneous analyte ion determination. Therefore, improved analytical performance can be obtained using BiSnFE compared to pure BiFE. This work also reports for the first time the use of the electrochemical impedance spectroscopy technique to analyse SnFEs and BiSnFEs. The latter analysis showed that the electro-analytical system is under kinetic- and diffusion-controlled processes for SnFEs, whereas BiSnFE is under a kinetic-controlled process. A possible interference effect on the Zn(II), Cd(II), and Pb(II) stripping signals was tested for the presence of Fe(II), As(III), Na(I), K(I), Ca(II), Mg(II), Cu(II), Sb(III), and NO3- ions in the analysed solution. Finally, an analysis of tap water was performed using an electrode with a Bi(III):Sn(II) ratio of 0.4:0.6 at 0.5 mg/L total mass concentration.
引用
收藏
页码:676 / 685
页数:10
相关论文
共 50 条
[11]   2-Mercaptobenzimidazole as a copper corrosion inhibitor: Part I. Long-term immersion, 3D-profilometry, and electrochemistry [J].
Finsgar, Matjaz .
CORROSION SCIENCE, 2013, 72 :82-89
[12]   Antimony film electrode for electrochemical stripping analysis [J].
Hocevar, Samo B. ;
Svancara, Ivan ;
Ogorevc, Bozidar ;
Vytras, Karel .
ANALYTICAL CHEMISTRY, 2007, 79 (22) :8639-8643
[13]   Ex situ preparation of bismuth film microelectrode for use in electrochemical stripping microanalysis [J].
Hutton, EA ;
Hocevar, SB ;
Ogorevc, M .
ANALYTICA CHIMICA ACTA, 2005, 537 (1-2) :285-292
[14]   An electrochemical sensor based on the reduction of screen-printed bismuth oxide for the determination of trace lead and cadmium [J].
Hwang, Gil-Ho ;
Han, Won-Kyu ;
Park, Joon-Shik ;
Kang, Sung-Goon .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 135 (01) :309-316
[15]   Copper film electrode for anodic stripping voltammetric determination of trace mercury and lead [J].
Jovanovski, V. ;
Hrastnik, N. I. ;
Hocevar, S. B. .
ELECTROCHEMISTRY COMMUNICATIONS, 2015, 57 :1-4
[16]   Bismuth electrodes in contemporary electroanalysis [J].
Jovanovski, Vasko ;
Hocevar, Samo B. ;
Ogorevc, Bozidar .
CURRENT OPINION IN ELECTROCHEMISTRY, 2017, 3 (01) :114-122
[17]   Ex Situ Prepared Antimony Film Electrode for Electrochemical Stripping Measurement of Heavy Metal Ions [J].
Jovanovski, Vasko ;
Hocevar, Samo B. ;
Ogorevc, Bozidar .
ELECTROANALYSIS, 2009, 21 (21) :2321-2324
[18]   Development of disposable bulk-modified screen-printed electrode based on bismuth oxide for stripping chronopotentiometric analysis of lead (II) and cadmium (II) in soil and water samples [J].
Kadara, Rashid O. ;
Tothill, Ibtisam E. .
ANALYTICA CHIMICA ACTA, 2008, 623 (01) :76-81
[19]   A study of bismuth-film electrodes for the detection of trace metals by anodic stripping voltammetry and their application to the determination of Pb and Zn in tapwater and human hair [J].
Kefala, G ;
Economou, A ;
Voulgaropoulos, A ;
Sofoniou, M .
TALANTA, 2003, 61 (05) :603-610
[20]   Polymer-coated bismuth film electrodes for the determination of trace metals by sequential-injection analysis/anodic stripping voltarnmetry [J].
Kefala, Georgia ;
Economou, Anastasios .
ANALYTICA CHIMICA ACTA, 2006, 576 (02) :283-289