Intensity-modulated arc therapy: principles, technologies and clinical implementation

被引:139
作者
Yu, Cedric X. [1 ]
Tang, Grace [1 ]
机构
[1] Univ Maryland, Sch Med, Baltimore, MD 21201 USA
关键词
LEAF POSITION OPTIMIZATION; DYNAMIC MULTILEAF COLLIMATOR; QUALITY-ASSURANCE; RADIATION-THERAPY; SINGLE-ARC; CONFORMAL RADIOTHERAPY; HELICAL TOMOTHERAPY; INITIAL CONDITIONS; DOSE-RATE; DELIVERY;
D O I
10.1088/0031-9155/56/5/R01
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intensity-modulated arc therapy (IMAT) was proposed by Yu (1995 Phys. Med. Biol. 40 1435-49) as an alternative to tomotherapy. Over more than a decade, much progress has been made. The advantages and limitations of the IMAT technique have also been better understood. In recent years, single-arc forms of IMAT have emerged and become commercially adopted. The leading example is the volumetric-modulated arc therapy (VMAT), a single-arc form of IMAT that delivers apertures of varying weights with a single-arc rotation that uses dose-rate variation of the treatment machine. With commercial implementation of VMAT, wide clinical adoption has quickly taken root. However, there remains a lack of general understanding for the planning of such arc treatments, as well as what delivery limitations and compromises are made. Commercial promotion and competition add further confusion for the end users. It is therefore necessary to provide a summary of this technology and some guidelines on its clinical implementation. The purpose of this review is to provide a summary of the works from the radiotherapy community that led to wide clinical adoption, and point out the issues that still remain, providing some perspective on its further developments. Because there has been vast experience in IMRT using multiple intensity-modulated fields, comparisons between IMAT and IMRT are also made in the review within the areas of planning, delivery and quality assurance.
引用
收藏
页码:R31 / R54
页数:24
相关论文
共 85 条
[1]  
Bauman G, 2004, Med Dosim, V29, P18, DOI 10.1016/j.meddos.2003.09.003
[2]   Treatment planning for volumetric modulated arc therapy [J].
Bedford, James L. .
MEDICAL PHYSICS, 2009, 36 (11) :5128-5138
[3]   Evaluation of the Delta4 phantom for IMRT and VMAT verification [J].
Bedford, James L. ;
Lee, Young K. ;
Wai, Philip ;
South, Christopher P. ;
Warrington, Alan P. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (09) :N167-N176
[4]   COMMISSIONING OF VOLUMETRIC MODULATED ARC THERAPY (VMAT) [J].
Bedford, James L. ;
Warrington, Alan P. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (02) :537-545
[5]   REALIZATION AND VERIFICATION OF 3-DIMENSIONAL CONFORMAL RADIOTHERAPY WITH MODULATED FIELDS [J].
BORTFELD, T ;
BOYER, AL ;
SCHLEGEL, W ;
KAHLER, DL ;
WALDRON, TJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 30 (04) :899-908
[6]   Single-Arc IMRT? [J].
Bortfeld, Thomas ;
Webb, Steve .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (01) :N9-N20
[7]   X-RAY FIELD COMPENSATION WITH MULTILEAF COLLIMATORS [J].
BORTFELD, TR ;
KAHLER, DL ;
WALDRON, TJ ;
BOYER, AL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (03) :723-730
[8]   OPTIMIZATION OF STATIONARY AND MOVING BEAM RADIATION-THERAPY TECHNIQUES [J].
BRAHME, A .
RADIOTHERAPY AND ONCOLOGY, 1988, 12 (02) :129-140
[9]   SOLUTION OF AN INTEGRAL-EQUATION ENCOUNTERED IN ROTATION THERAPY [J].
BRAHME, A ;
ROOS, JE ;
LAX, I .
PHYSICS IN MEDICINE AND BIOLOGY, 1982, 27 (10) :1221-1229
[10]   Requirements for leaf position accuracy for dynamic multileaf collimation [J].
Budgell, GJ ;
Mott, JHL ;
Williams, PC ;
Brown, KJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (05) :1211-1227