Development of X-ray and Gamma-ray CZT detectors for Homeland Security Applications
被引:3
作者:
Lee, Kuen
论文数: 0引用数: 0
h-index: 0
机构:
Washington Univ, 1 Brookings Dr,CB 1105, St Louis, MO 63130 USAWashington Univ, 1 Brookings Dr,CB 1105, St Louis, MO 63130 USA
Lee, Kuen
[1
]
Martin, J. W.
论文数: 0引用数: 0
h-index: 0
机构:
Washington Univ, 1 Brookings Dr,CB 1105, St Louis, MO 63130 USAWashington Univ, 1 Brookings Dr,CB 1105, St Louis, MO 63130 USA
Martin, J. W.
[1
]
Garson, A. B., III
论文数: 0引用数: 0
h-index: 0
机构:
Washington Univ, 1 Brookings Dr,CB 1105, St Louis, MO 63130 USAWashington Univ, 1 Brookings Dr,CB 1105, St Louis, MO 63130 USA
Garson, A. B., III
[1
]
Beilicke, M.
论文数: 0引用数: 0
h-index: 0
机构:
Washington Univ, 1 Brookings Dr,CB 1105, St Louis, MO 63130 USAWashington Univ, 1 Brookings Dr,CB 1105, St Louis, MO 63130 USA
Beilicke, M.
[1
]
Guo, Q.
论文数: 0引用数: 0
h-index: 0
机构:
Washington Univ, 1 Brookings Dr,CB 1105, St Louis, MO 63130 USAWashington Univ, 1 Brookings Dr,CB 1105, St Louis, MO 63130 USA
Guo, Q.
[1
]
Li, Q.
论文数: 0引用数: 0
h-index: 0
机构:
Washington Univ, 1 Brookings Dr,CB 1105, St Louis, MO 63130 USAWashington Univ, 1 Brookings Dr,CB 1105, St Louis, MO 63130 USA
Li, Q.
[1
]
De Geronimo, G.
论文数: 0引用数: 0
h-index: 0
机构:
Instrumentat Div, Upton, NY USAWashington Univ, 1 Brookings Dr,CB 1105, St Louis, MO 63130 USA
De Geronimo, G.
[2
]
Groza, M.
论文数: 0引用数: 0
h-index: 0
机构:
Fisk Univ, Nashville, TN 37208 USAWashington Univ, 1 Brookings Dr,CB 1105, St Louis, MO 63130 USA
Groza, M.
[3
]
论文数: 引用数:
h-index:
机构:
Burger, A.
[3
]
论文数: 引用数:
h-index:
机构:
Krawczynski, H.
[1
]
机构:
[1] Washington Univ, 1 Brookings Dr,CB 1105, St Louis, MO 63130 USA
[2] Instrumentat Div, Upton, NY USA
[3] Fisk Univ, Nashville, TN 37208 USA
来源:
DETECTION AND SENSING OF MINES, EXPLOSIVE OBJECTS, AND OBSCURED TARGETS XV
|
2010年
/
7664卷
关键词:
CZT;
X-ray Detector;
Cross-Strip Detector;
D O I:
10.1117/12.850113
中图分类号:
TP7 [遥感技术];
学科分类号:
081102 ;
0816 ;
081602 ;
083002 ;
1404 ;
摘要:
Cadmium Zinc Telluride (CZT) continues to progress in quality and cost as a material for the detection of hard X-ray and gamma-ray photons with excellent spatial and energy resolutions. We are developing large-volume (0.5x3.9x3.9 cm(3)) cross-strip CZT detectors with the objective to combine the excellent performance achieved so far only with pixelated CZT detectors with a reduced number of readout channels. In this contribution, we discuss the spectroscopic performance of large volume CZT detectors from the company Orbotech when contacted as pixelated detectors. Subsequently, we present results obtained when the same substrates where contacted with cross-strip contacts. Finally, we use the results from a simulation study to discuss the optimization of the design of the strip contacts and the readout electronics.