The applications of solid-phase microextraction (SPME) are continuously expanding, and one of the most interesting current aspects consists of applying SPME for fast analysis of biological fluids. The goal of this study is to develop biocompatible SPME coatings that can be utilized for in vivo and in vitro extractions, in direct contact with a biological matrix such as blood or tissue. The biocompatibility of the proposed new coatings is confirmed by X-ray photoelectron spectroscopy, and their performance is tested by developing an SPME/HPLC method for analysis of verapamil, loperamide, diazepam, nordiazepam, and warfarin in buffer solutions and in human plasma. The coatings prove to be biocompatible by not adsorbing proteins and are successfully applied for fast drug analysis and assay of drug plasma protein binding.
引用
收藏
页码:6903 / 6911
页数:9
相关论文
共 51 条
[1]   Solid phase microextraction for quantitative analysis in nonequilibrium situations [J].
Ai, J .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1230-1236
[2]   Ionic liquids in analytical chemistry [J].
Anderson, Jared L. ;
Armstrong, Daniel W. ;
Wei, Guor-Tzo .
ANALYTICAL CHEMISTRY, 2006, 78 (09) :2892-2902
[3]   An analytical view of ionic liquids [J].
Baker, GA ;
Baker, SN ;
Pandey, S ;
Bright, FV .
ANALYST, 2005, 130 (06) :800-808
[4]   Development and validation of a 96-well equilibrium dialysis apparatus for measuring plasma protein binding [J].
Banker, MJ ;
Clark, TH ;
Williams, JA .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2003, 92 (05) :967-974
[5]   New insights in dialysis membrane biocompatibility: relevance of adsorption properties and heparin binding [J].
Chanard, J ;
Lavaud, S ;
Randoux, C ;
Rieu, P .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2003, 18 (02) :252-257
[6]   Measurements of drug-protein binding by using immobilized human serum albumin liquid chromatography-mass spectrometry [J].
Cheng, Y ;
Ho, E ;
Subramanyam, B ;
Tseng, HL .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 809 (01) :67-73
[7]   Application of microdialysis in pharmacokinetic studies [J].
Elmquist, WF ;
Sawchuk, RJ .
PHARMACEUTICAL RESEARCH, 1997, 14 (03) :267-288
[8]  
FREEMANTLE M, 2005, C E NEWS 0801, P33
[9]   Semi-automatic high-throughput determination of plasma protein binding using a 96-well plate filtrate assembly and fast liquid chromatography-tandem mass spectrometry [J].
Fung, EN ;
Chen, YH ;
Lau, YY .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 795 (02) :187-194
[10]  
Hardman J., 2001, GOODMAN GILMANS PHAR