Anterior thoracolumbar instrumentation: Stiffness and load sharing characteristics of plate and rod systems

被引:39
|
作者
Brodke, DS
Gollogly, S
Bachus, KN
Mohr, RA
Nguyen, BKN
机构
[1] Univ Utah, Sch Med, Dept Orthopaed, Salt Lake City, UT USA
[2] Univ Utah, Orthopaed Bioengn Res Lab, Salt Lake City, UT USA
关键词
lumbar spine; thoracic spine; corpectomy reconstruction; instrumentation; biomechanics; load sharing;
D O I
10.1097/01.BRS.0000083201.55495.0E
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. An in vitro biomechanical study using a thoracolumbar corpectomy model to compare load sharing capabilities and stiffnesses of six different anterior instrumentation systems (three rod styles and three plate styles) for stabilizing the thoracic and lumbar spine. Objectives. To evaluate the axial load sharing capabilities of the instrumentation in a thoracolumbar corpectomy model and to measure the bending stiffness of the anterior instrumentation systems for the axes of flexion extension, lateral bending, and axial rotation with and without an anterior column graft in place. Summary of Background Data. Prior publications have analyzed biomechanical characteristics of many spinal instrumentation systems. These reports have compared anterior instrumentation systems with posterior instrumentation systems, in situ fusion techniques, intervertebral spacers, structural allograft and instrumentation, and combined anterior and posterior instrumentation. Other reports have published data on the biomechanical characteristics of typical anterior and posterior spinal instrumentation systems. However, there are no published reports that specifically compare the characteristics of anterior plate-style with anterior rod-style systems, or examining load sharing capabilities. Methods. Six constructs of each of six instrumentation systems were mounted on simulated vertebral bodies. A custom four-axis spine simulator was used to apply independent flexion-extension, lateral bending, and axial rotation moments as well as axial compressive loads. Axial load sharing was measured through a range of applied axial loads from 50 N to 500 N with rotational moments maintained at 0 Nm. The bending stiffness of each construct was calculated in response to +/-5.0 Nm moments about each axis of rotation with a 50 N compressive axial load with a full-length corpectomy graft in place, simulating reconstruction of the anterior column, and with no graft in place, simulating catastrophic graft failure. Statistical significance was determined using an analysis of variance and Fisher PLSD post hoc test with an alpha less than or equal to 0.05. Results. Load sharing results ranged from 63% to 89%. There was an inverse relationship between load sharing and stiffness. No correlation was found between load sharing and implant style (rod vs. plate). With the graft in place, stiffness result varied by instrumentation system rather than by plate/rod style. Without the graft, the stiffness of the constructs decreased approximately one-third in flexion-extension, two-thirds in lateral bending, and one-fifth in axial rotation, underlying the importance of the graft in overall construct stiffness. Conclusions. For both load sharing and stiffness, there is more influence from the design of the instrumentation system, than whether it is a plate or rod style system. The graft contributed to overall construct stiffness, particularly in lateral bending.
引用
收藏
页码:1794 / 1801
页数:8
相关论文
共 46 条
  • [1] Anterior cervical graft and plate load sharing
    Rapoff, AJ
    O'Brien, TJ
    Ghanayem, AJ
    Heisey, DM
    Zdeblick, TA
    JOURNAL OF SPINAL DISORDERS, 1999, 12 (01): : 45 - 49
  • [2] New rod-plate anterior instrumentation for thoracolumbar/lumbar scoliosis: Biomechanical evaluation compared with dual-rod and single-rod with structural interbody support
    Zhang, Hong
    Johnston, Charles E., II
    Pierce, William A.
    Ashman, Richard B.
    Bronson, Dwight G.
    Haideri, Nessie F.
    SPINE, 2006, 31 (25) : E934 - E940
  • [3] Static and dynamic analysis of five anterior instrumentation systems for thoracolumbar scoliosis
    Shimamoto, N
    Kotani, Y
    Shono, Y
    Kadoya, K
    Abumi, K
    Minami, A
    Kaneda, K
    SPINE, 2003, 28 (15) : 1678 - 1685
  • [4] DUAL-ROD INSTRUMENTATION VIA THE ANTERIOR APPROACH FOR THORACOLUMBAR AND LUMBAR ADOLESCENT IDIOPATHIC SCOLIOSIS
    Sudo, Hideki
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2022, 12 (04):
  • [5] Single screw-rod anterior instrumentation for thoracolumbar burst fractures with incomplete neurological deficit
    Sharma, Siddhartha
    Singh, Dara
    Singh, Manjeet
    Kohli, Arvind
    Singh, Gurjit
    Arora, Mohit
    JOURNAL OF ORTHOPAEDIC SURGERY, 2013, 21 (01): : 71 - 76
  • [6] An In Vitro Biomechanical Comparison of Single-Rod, Dual-Rod, and Dual-Rod With Transverse Connector in Anterior Thoracolumbar Instrumentation
    Reddy, Chandan G.
    Magnetta, Michael
    Dahdaleh, Nader S.
    Demmer, Matthew
    Iyamah, Kingsley Abode
    Lim, Tae-Hong
    Torner, James C.
    Hitchon, Patrick W.
    NEUROSURGERY, 2012, 70 (04) : 1017 - 1023
  • [7] Anterior instrumentation of the spine in thoracic and thoracolumbar fractures - The single rod versus the double rod Slot-Zielke device
    vanLoon, JLM
    Slot, GH
    Pavlov, PW
    SPINE, 1996, 21 (06) : 734 - 739
  • [9] Anterior single rod instrumentation for thoracolumbar adolescent idiopathic scoliosis with and without the use of structural interbody support
    Lowe, TG
    Alongi, PR
    Smith, DAB
    O'Brien, MF
    Mitchell, SL
    Pinteric, RJ
    SPINE, 2003, 28 (19) : 2232 - 2241
  • [10] Single- versus dual-rod anterior instrumentation of thoracolumbar curves in adolescent idiopathic scoliosis
    Nambiar, Mithun
    Yang, Yi
    Liew, Susan
    Turner, Peter L.
    Torode, Ian P.
    EUROPEAN SPINE JOURNAL, 2016, 25 (10) : 3249 - 3255