Optimum energy use to satisfy indoor air quality needs

被引:27
作者
Joo, Jinkyu [2 ]
Zheng, Qi [1 ]
Lee, Goonjae [1 ]
Kim, Jeong Tai [1 ]
Kim, Sunkuk [1 ]
机构
[1] Kyung Hee Univ, Dept Architectural Engn, Yongin 446701, Gyeonggi Do, South Korea
[2] Shindongah Engn & Construct, Seoul 501830, South Korea
基金
新加坡国家研究基金会;
关键词
Indoor air quality; Air exchange rate; Makeup air rate; Recirculation air rate; Cooling/heating load;
D O I
10.1016/j.enbuild.2011.10.045
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor air quality is important to occupant health. Ventilation is a widely used technique for improving indoor air quality. However, improper ventilation results in heat losses up to 70.0% and is often the source of energy usage problems. According to the final report of the HOPE [11], the simultaneous assurance of ventilation, energy reduction and occupant health remains a design challenge. In addition, CO2 is a pollutant which is largely impacted by air exchange, the effects of which cannot be neglected in indoor air quality. Therefore, this study focuses on levels of CO2 and calculates the makeup air rate and recirculation air rate of indoor spaces. The optimum ratio of makeup air and recirculation air is evaluated in Korea to maintain acceptable indoor air quality and to save energy. (c) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:62 / 67
页数:6
相关论文
共 22 条
  • [1] [Anonymous], 2000, AIR QUAL GUID EUR
  • [2] Research on seasonal indoor thermal environment and residents' control behavior of cooling and heating systems in Korea
    Bae, Chihye
    Chun, Chungyoon
    [J]. BUILDING AND ENVIRONMENT, 2009, 44 (11) : 2300 - 2307
  • [3] Baek C.I., 2005, E J, V34, P9
  • [4] A new methodology for the design of low energy buildings
    Chlela, Fadi
    Husaunndee, Ahmad
    Inard, Christian
    RiedeFer, Peter
    [J]. ENERGY AND BUILDINGS, 2009, 41 (09) : 982 - 990
  • [5] Estimation of optimum requirements for indoor air quality and energy consumption in some residences in Kuwait
    Elkilani, A
    Bouhamra, W
    [J]. ENVIRONMENT INTERNATIONAL, 2001, 27 (06) : 443 - 447
  • [6] European Communities, 2003, VENT GOOD IND AIR QU, P97
  • [7] USE OF AN INDOOR AIR-QUALITY MODEL (IAQM) TO ESTIMATE INDOOR OZONE LEVELS
    HAYES, SR
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1991, 41 (02): : 161 - 170
  • [8] Jokl M.V., 2003, ACTA POLYTECH, V43, P22
  • [9] Jung H.J., 2004, WELL BEING RESIDENTI, P171
  • [10] Analysis of thermal comfort and indoor air quality in a mechanically ventilated theatre
    Kavgic, M.
    Mumovic, D.
    Stevanovic, Z.
    Young, A.
    [J]. ENERGY AND BUILDINGS, 2008, 40 (07) : 1334 - 1343