Response-only method for damage detection of beam-like structures using high accuracy frequencies with auxiliary mass spatial probing

被引:60
|
作者
Zhong, Shuncong [1 ]
Yadiji, S. Olutunde [1 ]
Ding, Kang [2 ]
机构
[1] Univ Manchester, Sch Mech Aerosp & Civil Engn, Dynam & Aeroelast Res Grp, Manchester M13 9PL, Lancs, England
[2] S China Univ Technol, Fac Automobile Engn, Guangzhou, Guangdong, Peoples R China
关键词
D O I
10.1016/j.jsv.2007.10.004
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper proposes a new approach based on auxiliary mass spatial probing using spectral centre correction method (SCCM), to provide a simple solution for damage detection by just using the response time history of beam-like structures. The natural frequencies of a damaged beam with a traversing auxiliary mass change due to change in the inertia of the beam as the auxiliary mass is traversed along the beam, as well as the point-to-point variations in the flexibility of the beam. Therefore the auxiliary mass call enhance the effects of the crack on the dynamics of the beam and, therefore, facilitate the identification and location of damage in the beam. That is, the auxiliary mass can be used to probe the dynamic characteristic of the beam by traversing the mass from one end of the beam to the other. However, it is impossible to obtain accurate modal frequencies by the direct operation of the fast Fourier transform (FFT) of the response data of the structure because the frequency spectrum can be only calculated from limited sampled time data which results in the well-known leakage effect. SCCM is identical to the energy centrobaric correction method (ECCM) which is a practical and effective method used in rotating mechanical fault diagnosis and which resolves the shortcoming of FFT and can provide high accuracy estimate of frequency, amplitude and phase. In the present work, the modal responses of damaged simply supported beams with auxiliary mass are computed using the finite element method (FEM). The graphical plots of the natural frequencies calculated by SCCM versus axial location of auxiliary mass are obtained. However, it is difficult to locate the crack directly from the curve of natural frequencies. A simple and fast method, the derivatives of natural frequency curve, is proposed in the paper which can provide crack information for damage detection of beam-like structures. The efficiency and practicability of the proposed method is illustrated via numerical simulation. For real cases, experimental noise is expected to corrupt the response data and, ultimately, the natural frequencies of beam-like structures. Therefore, the response data with a normally distributed random noise is also studied. Also, the effects of crack depth, auxiliary mass and damping ratios oil the proposed method are investigated. From the simulated results, the efficiency and robustness of the proposed method is demonstrated. The results show that the proposed method has low computational cost and high precision. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1075 / 1099
页数:25
相关论文
共 33 条
  • [1] Quasi-OCVT technique for response-only experimental modal analysis of beam-like structures
    Zhong, Jianfeng
    Zhong, Shuncong
    Zhang, Qiukun
    STRUCTURAL CONTROL & HEALTH MONITORING, 2017, 24 (11):
  • [2] Damage Detection in Beam-Like Structures by Using the PCA-Method
    Bellino, A.
    Garibaldi, L.
    Marchesiello, S.
    Fasana, A.
    STRUCTURAL HEALTH MONITORING 2010, 2010, : 601 - 606
  • [3] Concentrated mass localization in beam-like structures using natural frequencies
    Sha, Ganggang
    Radzienski, Maciej
    Soman, Rohan
    Cao, Maosen
    Ostachowicz, Wieslaw
    HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS IX, 2020, 11381
  • [4] Wavelet-Based Damage Detection Method for Beam-Like Structures
    Gokdag, Hakan
    GAZI UNIVERSITY JOURNAL OF SCIENCE, 2010, 23 (03): : 339 - 349
  • [5] A novel method for crack detection in beam-like structures by measurements of natural frequencies
    Khiem, N. T.
    Toan, L. K.
    JOURNAL OF SOUND AND VIBRATION, 2014, 333 (18) : 4084 - 4103
  • [6] Damage detection in beam-like structures using static shear energy redistribution
    Peng, Xi
    Yang, Qiuwei
    FRONTIERS OF STRUCTURAL AND CIVIL ENGINEERING, 2022, 16 (12) : 1552 - 1564
  • [7] Damage detection in beam-like structures using static shear energy redistribution
    Xi Peng
    Qiuwei Yang
    Frontiers of Structural and Civil Engineering, 2022, 16 : 1552 - 1564
  • [8] Damage detection in beam-like structures using static shear energy redistribution
    XiPENG
    Qiuwei YANG
    Frontiers of Structural and Civil Engineering, 2022, 16 (12) : 1552 - 1564
  • [9] Mode shape area difference method for sparse damage detection in beam-like structures
    Pajan, Jurica
    Duvnjak, Ivan
    Bartolac, Marko
    Ereiz, Suzana
    STRUCTURAL CONCRETE, 2024,
  • [10] Beam-like damage detection methodology using wavelet damage ratio and additional roving mass
    Santos, Juliana C.
    de Morais, Marcus V. G.
    Machado, Marcela R.
    Silva, Ramon
    Palechor, Erwin U. L.
    Silva, Welington, V
    FRATTURA ED INTEGRITA STRUTTURALE-FRACTURE AND STRUCTURAL INTEGRITY, 2022, 16 (62): : 349 - 363