The impact of sampling time on peak capacity and analysis speed in on-line comprehensive two-dimensional liquid chromatography

被引:58
作者
Potts, Lawrence W. [1 ]
Stoll, Dwight R. [1 ]
Li, Xiaoping [2 ]
Carr, Peter W. [2 ]
机构
[1] Gustavus Adolphus Coll, Dept Chem, St Peter, MN 56082 USA
[2] Univ Minnesota, Dept Chem, Minneapolis, MN 55455 USA
基金
美国国家卫生研究院;
关键词
2DLC; LC x LC; 2D on-line comprehensive chromatography; Multidimensional separations; Optimization; Peak capacity; Under-sampling; Re-equilibration; Cycle times; Sampling times; Peptides; Gradient elution; Isocratic elution; PARALLEL FACTOR-ANALYSIS; GRADIENT ELUTION; GAS-CHROMATOGRAPHY; X GC; TEMPERATURE; SEPARATIONS; PERFORMANCE; RESOLUTION; COLUMNS; OPTIMIZATION;
D O I
10.1016/j.chroma.2010.07.009
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Comprehensive two-dimensional liquid chromatography (2DLC) offers a number of practical advantages over optimized one-dimensional LC in peak capacity and thus in resolving power. The traditional "product rule" for overall peak capacity for a 2DLC system significantly overestimates peak capacity because it neglects under-sampling of the first dimension separation. Here we expand on previous work by more closely examining the effects of the first dimension peak capacity and gradient time, and the second dimension cycle times on the overall peak capacity of the 2DLC system. We also examine the effects of re-equilibration time on under-sampling as measured by the under-sampling factor and the influence of molecular type (peptide vs. small molecule) on peak capacity. We show that in fast 20 separations (less than 1 h), the second dimension is more important than the first dimension in determining overall peak capacity and conclude that extreme measures to enhance the first dimension peak capacity are usually unwarranted. We also examine the influence of sample types (small molecules vs. peptides) on second dimension peak capacity and peak capacity production rates, and how the sample type influences ptimum second dimension gradient and re-equilibration times. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:5700 / 5709
页数:10
相关论文
共 50 条
[21]   Multidimensional separation of peptides for effective proteomic analysis [J].
Issaq, HJ ;
Chan, KC ;
Janini, GM ;
Conrads, TP ;
Veenstra, TD .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 817 (01) :35-47
[22]  
Karger B.L., 1973, INTRO SEPARATION SCI
[23]   Equation for Peak Capacity Estimation in Two-Dimensional Liquid Chromatography [J].
Li, Xiaoping ;
Stoll, Dwight R. ;
Carr, Peter W. .
ANALYTICAL CHEMISTRY, 2009, 81 (02) :845-850
[24]   Practice and theory of high temperature liquid chromatography [J].
McNeff, Clayton V. ;
Yan, Bingwen ;
Stoll, Dwight R. ;
Henry, Richard A. .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (11) :1672-1685
[25]   Effect of sampling rate on resolution in comprehensive two-dimensional liquid chromatography [J].
Murphy, RE ;
Schure, MR ;
Foley, JP .
ANALYTICAL CHEMISTRY, 1998, 70 (08) :1585-1594
[26]   Theory of peak capacity in gradient elution [J].
Neue, UD .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1079 (1-2) :153-161
[27]   Peak capacity in unidimensional chromatography [J].
Neue, Uwe Dieter .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1184 (1-2) :107-130
[28]   Analysis of four-way two-dimensional liquid chromatography-diode array data: Application to metabolomics [J].
Porter, Sarah E. G. ;
Stoll, Dwight R. ;
Rutan, Sarah C. ;
Carr, Peter W. ;
Cohen, Jerry D. .
ANALYTICAL CHEMISTRY, 2006, 78 (15) :5559-5569
[29]   Highly efficient peptide separations in proteomics Part 2: Bi- and multidimensional liquid-based separation techniques [J].
Sandra, Koen ;
Moshir, Mahan ;
D'hondt, Filip ;
Tuytten, Robin ;
Verleysen, Katleen ;
Kas, Koen ;
Francois, Isabelle ;
Sandra, Pat .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (11-12) :1019-1039
[30]   High-speed gradient elution reversed-phase liquid chromatography of bases in buffered eluents - Part I. Retention repeatability and column re-equilibration [J].
Schellinger, Adam P. ;
Stoll, Dwight R. ;
Carr, Peter W. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1192 (01) :41-53